{"product_id":"apc-ap7902b-switched-rack-pdu-2u-30a-120v-with-16-outlets-mtiwl","title":"APC AP7902B - Switched Rack PDU 2U 30A 120V with 16 Outlets","description":"\u003cp\u003e[shortdesc]\u003cbr\u003e\u003cbr\u003e\n2U Switched PDU, 30A 120V Input, 16 NEMA 5-20R Outlets, Horizontal Mount, Remote Control \u0026amp; Monitoring\u003cbr\u003e\u003cbr\u003e[\/shortdesc]\u003c\/p\u003e \n\n\u003cp\u003e[properties] \n\u003c\/p\u003e\u003ctable width=\"1024\"\u003e\n\u003ctr\u003e\n \u003ctd width=\"512\"\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"512\"\u003eAPC by Schneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n \u003ctd width=\"512\"\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"512\"\u003eAP7902B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n \u003ctd width=\"512\"\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"512\"\u003eNetShelter Switched Rack PDU\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n \u003ctd width=\"512\"\u003e\u003cstrong\u003eForm Factor\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"512\"\u003eRackmount 2U\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n \u003ctd width=\"512\"\u003e\u003cstrong\u003eDimensions (H x W x D\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"512\"\u003e3.5\" x 17.5\" x 4.5\" (89 x 445 x 114 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n \u003ctd width=\"512\"\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"512\"\u003e9.9 lb (4.5 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n \u003ctd width=\"512\"\u003e\u003cstrong\u003eColor\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"512\"\u003eBlack\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n \u003ctd width=\"512\"\u003e\u003cstrong\u003eNumber of Rack Units\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"512\"\u003e2U\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n \u003ctd width=\"512\"\u003e\u003cstrong\u003eMounting Mode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"512\"\u003eRack-mounted (Horizontal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n \u003ctd width=\"512\"\u003e\u003cstrong\u003eCooling\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"512\"\u003eNot specified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n[\/properties]\n\n\u003cp\u003e[specifications]\n\u003c\/p\u003e\u003ctable width=\"1024\"\u003e\n\u003ctr\u003e\n \u003ctd width=\"512\"\u003e\u003cstrong\u003ePDU Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"512\"\u003eSwitched\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n \u003ctd width=\"512\"\u003e\u003cstrong\u003eInput Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"512\"\u003e100–120 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n \u003ctd width=\"512\"\u003e\u003cstrong\u003eOutput Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"512\"\u003e120 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n \u003ctd width=\"512\"\u003e\u003cstrong\u003eInput Plug Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"512\"\u003eNEMA L5-30P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n \u003ctd width=\"512\"\u003e\u003cstrong\u003eInput Frequency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"512\"\u003e50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n \u003ctd width=\"512\"\u003e\u003cstrong\u003eLine Rated Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"512\"\u003e24 A (Max 30 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n \u003ctd width=\"512\"\u003e\u003cstrong\u003eLoad Capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"512\"\u003e2880 VA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n \u003ctd width=\"512\"\u003e\u003cstrong\u003eOutlets\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"512\"\u003e16 × NEMA 5-20R\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n \u003ctd width=\"512\"\u003e\u003cstrong\u003eCommunication Ports\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"512\"\u003eNot specified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n \u003ctd width=\"512\"\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"512\"\u003e32–113 °F (0–45 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n \u003ctd width=\"512\"\u003e\u003cstrong\u003eStorage Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"512\"\u003e-13–149 °F (-25–65 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n \u003ctd width=\"512\"\u003e\u003cstrong\u003eOperating Humidity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"512\"\u003e0–95%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n \u003ctd width=\"512\"\u003e\u003cstrong\u003eStorage Humidity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"512\"\u003e0–95%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n \u003ctd width=\"512\"\u003e\u003cstrong\u003eOperating Altitude\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"512\"\u003e0–10,000 ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n \u003ctd width=\"512\"\u003e\u003cstrong\u003eStorage Altitude\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"512\"\u003e0–50,000 ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n \u003ctd width=\"512\"\u003e\u003cstrong\u003eCompliance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"512\"\u003ecUL Listed, CSA, Industry Canada, UL Listed, FCC Part 15 Class A, ICES-003, UL 60950, RoHS, REACh\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"512\"\u003e\u003cstrong\u003eWarranty\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"512\"\u003e2 years repair or replace\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n[\/specifications]\n\n\u003cp\u003e[accessories]\n\u003c\/p\u003e\u003ctable width=\"1024\"\u003e\n\u003ctr\u003e\n \u003ctd width=\"512\"\u003e\u003cstrong\u003eCord Retention Brackets\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"512\"\u003eIncluded in the box\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n \u003ctd width=\"512\"\u003e\u003cstrong\u003eHorizontal Mounting Brackets\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"512\"\u003eIncluded in the box\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n \u003ctd width=\"512\"\u003e\u003cstrong\u003eUser Manual\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"512\"\u003eIncluded in the box\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n \u003ctd width=\"512\"\u003e\u003cstrong\u003eInstallation Guide\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"512\"\u003eIncluded in the box\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n[\/accesories]\n\n\u003ch2\u003eOverview\u003c\/h2\u003e\n\u003cp\u003eThe APC AP7902B Switched Rack PDU is designed to provide reliable, high-density power distribution with remote on\/off outlet control. Built for demanding IT environments, this 2U horizontal PDU supports up to 30A at 120V with 16 managed outlets. Engineered for efficiency, it allows administrators to monitor load levels, optimize usage, and control devices remotely for maximum uptime and operational flexibility.\u003c\/p\u003e\n\n\u003ch2\u003eKey Features \u0026amp; Benefits\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSwitched Control:\u003c\/strong\u003e Individual outlet management enables remote power cycling and equipment reboot.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh Capacity Design:\u003c\/strong\u003e 30A, 120V input delivers 2880 VA load capacity to critical equipment.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e16 NEMA 5-20R Outlets:\u003c\/strong\u003e Supports multiple servers, storage, and networking devices in a rack.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRack-Mount Form Factor:\u003c\/strong\u003e 2U horizontal design fits seamlessly into standard enclosures.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLoad Monitoring:\u003c\/strong\u003e Provides real-time visibility into current draw for capacity planning.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRobust Build:\u003c\/strong\u003e Durable APC construction with cord retention and mounting brackets included.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eTechnical Deep Dive\u003c\/h2\u003e\n\u003cp\u003eThe AP7902B utilizes switched PDU technology, giving IT managers granular control over each connected load. This functionality is crucial for reducing downtime, as individual outlets can be power-cycled remotely without sending staff on-site.\u003c\/p\u003e\n\u003cp\u003eIts 30A input capacity, combined with 16 NEMA 5-20R outlets, supports diverse rack equipment while ensuring balanced load distribution. Integrated current monitoring helps avoid circuit overload and enables proactive management of rack power usage.\u003c\/p\u003e\n\u003cp\u003eThe 2U rackmount design simplifies integration into existing infrastructure, while APC’s engineering standards guarantee consistent, dependable operation across enterprise IT, colocation, and edge environments.\u003c\/p\u003e\n\n\u003ch2\u003eIdeal Applications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eEnterprise server racks and IT closets\u003c\/li\u003e\n\u003cli\u003eNetwork and telecom infrastructure\u003c\/li\u003e\n\u003cli\u003eColocation and data center power distribution\u003c\/li\u003e\n\u003cli\u003eEdge computing deployments requiring remote management\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eFrequently Asked Questions (FAQs\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eQ1: How is the AP7902B installed?\u003c\/strong\u003e\u003cbr\u003eA: It mounts horizontally in a 2U rack space using included brackets, with flexible front or rear positioning.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ2: What performance can I expect?\u003c\/strong\u003e\u003cbr\u003eA: The PDU supports up to 30A at 120V with 2880 VA load capacity across 16 outlets. Runtime depends on connected UPS capacity.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ3: How can it be managed?\u003c\/strong\u003e\u003cbr\u003eA: Outlets are switchable via remote interfaces, allowing remote reboot, sequencing, and monitoring of connected devices.\u003c\/p\u003e","brand":"APC","offers":[{"title":"Default Title","offer_id":48012836208857,"sku":"AP7902B-NEW","price":1572.9,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0016\/5327\/6707\/files\/AP7902B_2_560ebc0d-2c0b-4b8e-a700-0b3216da08e7.webp?v=1771846580","url":"https:\/\/www.aloinfousa.com\/ar\/products\/apc-ap7902b-switched-rack-pdu-2u-30a-120v-with-16-outlets-mtiwl","provider":"aloinfousa.com","version":"1.0","type":"link"}