{"product_id":"cisco-ie-3300-8u2x-e-switch-f6hxi","title":"Cisco IE-3300-8U2X-E Switch","description":"\u003cdiv data-mce-fragment=\"1\" class=\"short-hide\"\u003e[shortdesc]\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli data-mce-fragment=\"1\"\u003eSwitch, managed, 8 x 10\/100\/1000 (4PPoE\/UPOE) + 2 x 10 Gigabit SFP+, DIN rail mountable, PoE++ (480 W)\u003c\/li\u003e\n\u003c\/ul\u003e\n[\/shortdesc]\u003c\/div\u003e\n\u003cp\u003e[properties]\u003c\/p\u003e\n\u003ctable data-mce-fragment=\"1\" width=\"502\"\u003e\n\u003ctbody data-mce-fragment=\"1\"\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"200\"\u003eProperties\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"302\"\u003eCisco IE-3300-8U2X-E\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"200\"\u003eDescription\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"302\"\u003eCatalyst IE3300 with 8 GE Copper (4PPoE Type 3) and 2 10G SFP+, Modular, Network Essentials\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"200\"\u003eProduct Family\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"302\"\u003eIndustrial Ethernet 3300\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"200\"\u003eProduct Type\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"302\"\u003eEthernet Switch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"502\" colspan=\"2\"\u003eSwitches\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"200\"\u003eTotal Ports\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"302\"\u003e10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"200\"\u003e10\/100\/1000 RJ45 Copper Ports\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"302\"\u003e8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"200\"\u003e100\/1000 SFP Ports\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"302\"\u003e-\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"200\"\u003e1GE\/2.5G RJ45 Copper ports\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"302\"\u003e-\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"200\"\u003e1GE\/10G SFP+ Ports\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"302\"\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"200\"\u003eSoftware License (Default)\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"302\"\u003eNetwork Essentials\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"200\"\u003ePoE\/PoE (+) budget\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"302\"\u003e480W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"502\" colspan=\"2\"\u003eSoftware Features\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"200\"\u003eNetwork Essentials\u003cbr data-mce-fragment=\"1\"\u003eLicense (Perpetual)\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"302\"\u003eFeatures\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"200\"\u003eLayer 2 Switching\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"302\"\u003eIEEE 802.1, 802.3 standard, NTP, UDLD, CDP, LLDP, unicast MAC filter, PAgP, LACP, VTPv2,\u003cbr data-mce-fragment=\"1\"\u003eVTPv3, EtherChannel, Q-in-Q tunneling, voice VLAN, PVST+, MSTP, and RSTP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"200\"\u003eMulticast\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"302\"\u003eIGMPv1, v2, v3 snooping, IGMP filtering, IGMP querier\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"200\"\u003eManagement\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"302\"\u003eWebUI, MIB, SmartPort, SNMP, syslog, DHCP server, SPAN session, RSPAN, FRSPAN,\u003cbr data-mce-fragment=\"1\"\u003eExpress setup, NETCONF, RESTCONF, Delayless IPDT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"200\"\u003eSecurity\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"302\"\u003ePort security, 802.1x, Dynamic Host Configuration Protocol (DHCP) snooping, dynamic ARP inspection, IP source guard, guest VLAN, MAC authentication bypass, 802.1x multidomain authentication, storm control - unicast, multicast, broadcast, SCP, SSH, SNMPv3, TACACS+, RADIUS server\/client, MAC address notification, BPDU guard, Access Lists (PACL,VACL,RACL), SUDI 2099 (Secure Unique Device identifier), Full Flexible NetFlow (FNF), MACsec-128\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"200\"\u003eQuality of Service (QoS)\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"302\"\u003eIngress policing, rate limit, egress queuing and shaping, auto QoS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"200\"\u003eIPv6\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"302\"\u003eIPv6 host support, SNMP over IPv6, HTTP\/HTTP(s) over IPv6, SNMP over IPv6, Syslog over IPv6, DHCPv6 relay source, DHCPv6 bulk lease query (RFC 5460), IPv6 stateless Auto Config SCP\/SSH, Radius, TACACS+, NTP over IPv6, IPv6 VRF aware BGPv6, IPV6 ND cache expire, IPv6 support for TFTP, IPv6 DNS transport, IPv6 QoS, IPv6 FHS RA Guard, IPv6 FHS DHCPv6 Guard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"200\"\u003eLayer 3 Routing\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"302\"\u003eInter-VLAN routing, Static routing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"200\"\u003eUtility\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"302\"\u003eDying gasp, SCADA protocol classification - GOOSE messaging, MODBUS TCP\/IP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"200\"\u003eIndustrial Ethernet\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"302\"\u003eCIP Ethernet\/IP, IEEE 1588 PTP v2 (Default profile), PROFINET\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"200\"\u003eRedundancy\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"302\"\u003eResilient Ethernet Protocol (REP) ring, PROFINET-Media Redundancy Protocol (MRP), REP Preferred, Fast REP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"200\"\u003eAutomation\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"302\"\u003eYANG, NETCONF, RESTCONF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"200\"\u003eIndustrial Management\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"302\"\u003eLayer 2 switching with 1:1 switch Network Address Translation (L2NAT) \u003cem\u003e(not supported on 10G uplink ports)\u003c\/em\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"200\"\u003eIOx\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"302\"\u003eContainer (Native docker)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"200\"\u003eDimensions (HxWxD) Inches\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"302\"\u003e6 in. X 4.4 in. X 5.3 in.\u003cbr data-mce-fragment=\"1\"\u003e15.2 cm. x 11.2 cm. x 13.5 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"200\"\u003eWeight\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"302\"\u003e4.5 lbs (2.0 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"200\"\u003eMounting\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"302\"\u003eDIN Rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"502\" colspan=\"2\"\u003eCisco Catalyst Center Features\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"200\"\u003eCatalyst Center Essentials\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"302\"\u003eCatalyst Center Advantage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"200\"\u003eElement Management\u003cbr data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003eDiscovery, Topology, Inventory, software image management\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"302\"\u003eElement Management\u003cbr data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003eDiscovery, Topology, Inventory, software image management; Patch\/SMU\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"200\"\u003eBasic Assurance\u003cbr data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003eHealth dashboard - Network, Client monitoring; switch and wired client health monitoring\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"302\"\u003eAssurance and Analytics\u003cbr data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003eCompliance, Custom Reports, Device 360 and Client 360 - Display device and client connectivity for granular troubleshooting\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"200\"\u003eBasic Automation\u003cbr data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003eCisco Network Plug-and-Play application\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"302\"\u003eSoftware-defined Access\u003cbr data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003eExtended Node, REP Ring Workflow for Extended Nodes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e[\/properties]\u003cbr\u003e\u003cbr\u003e[specifications]\u003c\/p\u003e\n\u003ctable data-mce-fragment=\"1\" width=\"753\"\u003e\n\u003ctbody data-mce-fragment=\"1\"\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"384\"\u003eSpecifications\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"369\"\u003eIE-3300-8U2X-E\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"384\"\u003eDRAM\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"369\"\u003e4 GB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"384\"\u003eFlash Memory\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"369\"\u003e1.5 GB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"753\" colspan=\"2\"\u003eHardware\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"384\"\u003ePoE power budget\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"369\"\u003eUp to 480W (including expansion module)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"384\"\u003eRemovable storage\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"369\"\u003eUSB (Optional), SD card (Optional)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"384\"\u003eAlarms\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"369\"\u003e2 alarms in, 1 alarm out\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"384\"\u003eConsole ports\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"369\"\u003e1 RS-232 (via RJ-45), 1 USB Mini Type B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"384\"\u003ePower inputs\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"369\"\u003eDual DC power inputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"384\"\u003eNumber of Queues\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"369\"\u003e8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"384\"\u003eForwarding Rate\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"369\"\u003eLine rate for all ports and all packet sizes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"384\"\u003eUnicast MAC addresses\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"369\"\u003e16000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"384\"\u003eJumbo Frames\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"369\"\u003e8996 bytes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"384\"\u003eNo. of VLANs\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"369\"\u003e256\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"384\"\u003eIPv4 Indirect routes\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"369\"\u003e3000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"384\"\u003eIPv6 Indirect routes\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"369\"\u003e512\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"384\"\u003eInternet Group Management Protocol (IGMP) Multicast Groups\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"369\"\u003e1000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"384\"\u003eSpanning Tree Protocol (STP) instances\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"369\"\u003e128\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"384\"\u003eAccess Control Entries (PACL\/VACL\/RACL)\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"369\"\u003e3000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"384\"\u003eSD card capacity (Optional)\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"369\"\u003e4 GB or 16 GB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"384\"\u003eInput Voltage Range\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"369\"\u003eRedundant DC input voltage: 9.6 to 60VDC\u003cbr data-mce-fragment=\"1\"\u003e48VDC is required for PoE and 54VDC is required for PoE+ \/ 4PPoE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"384\"\u003eMaximum Input Current\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"369\"\u003e10.5A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"384\"\u003ePower Consumption\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"369\"\u003e42W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"384\"\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"369\"\u003e-40°C to +70°C (40 LFM vented enclosure)\u003cbr data-mce-fragment=\"1\"\u003e-40°C to +60°C (sealed enclosure)\u003cbr data-mce-fragment=\"1\"\u003e-40°C to +75°C (Min. 200 LFM fan or blower-equipped enclosure)\u003cbr data-mce-fragment=\"1\"\u003e+85°C (type tested for 16 hours)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"384\"\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"369\"\u003e-40 C to +85 C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"384\"\u003eOperating Altitude\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"369\"\u003eUp to 15,000 feet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"384\"\u003eStorage Altitude\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"369\"\u003e15,000 feet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"384\"\u003eMean Time Between Failures (MTBF)\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"369\"\u003e436,034\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"384\"\u003eIndustrial Automation Control System\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"369\"\u003eIEC 62443-4-1\u003cbr data-mce-fragment=\"1\"\u003eIEC 62443-4-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"384\"\u003eElectromagnetic emissions\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"369\"\u003eFCC 47 CFR Part 15 subpart B Class A\u003cbr data-mce-fragment=\"1\"\u003eEN 55032\/CISPR 32 Class A\u003cbr data-mce-fragment=\"1\"\u003eVCCI Class A\u003cbr data-mce-fragment=\"1\"\u003eAS\/NZS CISPR 32 Class A\u003cbr data-mce-fragment=\"1\"\u003eCISPR 11 Class A\u003cbr data-mce-fragment=\"1\"\u003eICES 003 Class A\u003cbr data-mce-fragment=\"1\"\u003eCNS 13438 Class A\u003cbr data-mce-fragment=\"1\"\u003eKN 32 Class A\u003cbr data-mce-fragment=\"1\"\u003eEN 300 386\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"384\"\u003eElectromagnetic immunity\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"369\"\u003eCISPR 24 \/ EN 55024 \/ KN 35\u003cbr data-mce-fragment=\"1\"\u003eEN 61000-4-2 Electro Static Discharge (air 15kV, contact 8kV)\u003cbr data-mce-fragment=\"1\"\u003eEN 61000-4-3 Radiated RF (10V\/m UTP, 20V\/m STP)\u003cbr data-mce-fragment=\"1\"\u003eEN 61000-4-4 Electromagnetic Fast Transients (4kV)\u003cbr data-mce-fragment=\"1\"\u003eEN 61000-4-5 Surge (2KV\/1KV Power, 4KV STP)\u003cbr data-mce-fragment=\"1\"\u003eEN 61000-4-6 Conducted RF (10Vrms UTP)\u003cbr data-mce-fragment=\"1\"\u003eEN 61000-4-10 Damped Oscillatory Magnetic Field (100 A\/m)\u003cbr data-mce-fragment=\"1\"\u003eEN 61000-4-16 Conducted CM Disturbances (30V, Cont\/300V, 1 sec)\u003cbr data-mce-fragment=\"1\"\u003eEN 61000-4-17 Ripple Immunity DC Power (10%)\u003cbr data-mce-fragment=\"1\"\u003eEN 61000-4-18 Damped Oscillatory Wave (2.5kV, 1MHz)\u003cbr data-mce-fragment=\"1\"\u003eEN-61000-4-29 DC Voltage Dips and interruptions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"384\"\u003eIndustry standards\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"369\"\u003eEN 61000-6-2 Industrial Immunity\u003cbr data-mce-fragment=\"1\"\u003eEN 61000-6-4 Industrial Emissions\u003cbr data-mce-fragment=\"1\"\u003eEN 61000-6-1 Light Industrial Immunity\u003cbr data-mce-fragment=\"1\"\u003eEN 61326-1 Measurement, Control and Laboratory Equipment\u003cbr data-mce-fragment=\"1\"\u003eIEEE 1613 Electric Power Stations Communications Networking\u003cbr data-mce-fragment=\"1\"\u003eEN\/IEC 61850-3 Electric Substations Communications Networking\u003cbr data-mce-fragment=\"1\"\u003eEN50121-4 Railway Signaling and Telecommunications Apparatus\u003cbr data-mce-fragment=\"1\"\u003eEN50155- Railway applications - Rolling stock\u003cbr data-mce-fragment=\"1\"\u003eODVA Industrial EtherNet\/IP\u003cbr data-mce-fragment=\"1\"\u003eNEMA TS 2-2016\u003cbr data-mce-fragment=\"1\"\u003eIP30\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"384\"\u003eMarine I\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"369\"\u003eDNV Certification according to class guideline DNV-CG-0339\u003cbr data-mce-fragment=\"1\"\u003eAdditional Standards:\u003cbr data-mce-fragment=\"1\"\u003eIEC 60945, IACS UR E10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e[\/specifications]\u003cbr\u003e\u003cbr\u003e[accesories]\u003c\/p\u003e\n\u003ctable data-mce-fragment=\"1\" width=\"422\"\u003e\n\u003ctbody data-mce-fragment=\"1\"\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"422\" colspan=\"2\"\u003eAccessories and License Upgrade PIDs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"150\"\u003eSD-IE-16GB=\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"272\"\u003eIE 16GB SD memory card for IE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"150\"\u003eSTK-RACK-DINRAIL=\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"272\"\u003e19 in. DIN Rail mount kit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"150\"\u003eIE3300-NW-A=\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"272\"\u003eNetwork Advantage License for IE3300, Perpetual\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"150\"\u003eIE3300-DNA-E\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"272\"\u003eCisco Catalyst Center Essentials license for IE3300 Series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"150\"\u003eIE3300-DNA-E-3Y\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"272\"\u003eIE 3300 Cisco Catalyst Center Essentials, 3 Year Term license\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"150\"\u003eIE3300-DNA-E-5Y\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"272\"\u003eIE 3300 Cisco Catalyst Center Essentials, 5 Year Term license\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"150\"\u003eIE3300-DNA-E-7Y\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"272\"\u003eIE 3300 Cisco Catalyst Center Essentials, 7 Year Term license\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"150\"\u003eIE3300-DNA-A\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"272\"\u003eCisco Catalyst Center Advantage license for IE3300 Series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"150\"\u003eIE3300-DNA-A-3Y\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"272\"\u003eIE 3300 Cisco Catalyst Center Advantage, 3 Year Term license\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"150\"\u003eIE3300-DNA-A-5Y\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"272\"\u003eIE 3300 Cisco Catalyst Center Advantage, 5 Year Term license\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"150\"\u003eIE3300-DNA-A-7Y\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"272\"\u003eIE 3300 Cisco Catalyst Center Advantage, 7 Year Term license\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"150\"\u003eLIC-MRP-MGR-XE=\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"272\"\u003eMRP Ring Manager License\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"150\"\u003eLIC-MRP-CLIENT-XE=\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"272\"\u003eMRP Ring Client License\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"422\" colspan=\"2\"\u003eIE 3300 Series Power Supplies\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"150\"\u003ePWR-IE50W-AC=\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"272\"\u003e50W AC Power Supply\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"150\"\u003ePWR-IE50W-AC-IEC=\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"272\"\u003e50W AC-IEC Power Supply\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"150\"\u003ePWR-IE50W-AC-L=\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"272\"\u003e50W AC-L Power Supply\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"150\"\u003ePWR-IE65W-PC-AC=\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"272\"\u003e65W PC-AC Power Supply\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"150\"\u003ePWR-IE65W-PC-DC=\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"272\"\u003e65W PC-DC Power Supply\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"150\"\u003ePWR-IE170W-PC-AC=\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"272\"\u003e170W PC-AC Power Supply\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"150\"\u003ePWR-IE170W-PC-DC=\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"272\"\u003e170W PC-DC Power Supply\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"150\"\u003ePWR-IE240W-PCAC-L=\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"272\"\u003e240W PCAC-L Power Supply\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"150\"\u003ePWR-IE480W-PCAC-L=\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"272\"\u003e480W PCAC-L Power Supply\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"422\" colspan=\"2\"\u003eSFPs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"150\"\u003eGLC-FE-100FX-RGD=*\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"272\"\u003e100BASE-FX Rugged SFP for Fast Ethernet SFP Ports\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"150\"\u003eGLC-FE-100LX-RGD=*\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"272\"\u003e100BASE-LX10 Rugged SFP for Fast Ethernet SFP Ports\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"150\"\u003eGLC-FE-100FX=*\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"272\"\u003e100BASE-FX SFP for Fast Ethernet SFP Ports\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"150\"\u003eGLC-FE-100LX=*\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"272\"\u003e100BASE-LX10 SFP for Fast Ethernet SFP Ports\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"150\"\u003eGLC-FE-100EX=*\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"272\"\u003e100BASE-EX for Fast Ethernet SFP Ports\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"150\"\u003eGLC-FE-100ZX=*\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"272\"\u003e100BASE-ZX for Fast Ethernet SFP Ports\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"150\"\u003eGLC-FE-100BX-D=*\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"272\"\u003e100BASE-BX10-D SFP for Fast Ethernet SFP Ports\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"150\"\u003eGLC-FE-100BX-U=*\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"272\"\u003e100BASE-BX10-U SFP for Fast Ethernet SFP Ports\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"150\"\u003eGLC-SX-MM-RGD=\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"272\"\u003e1000BASE-SX short wavelength; rugged\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"150\"\u003eGLC-LX-SM-RGD=\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"272\"\u003e1000BASE-LX\/LH long wavelength; rugged\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"150\"\u003eGLC-ZX-SM-RGD=\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"272\"\u003e1000BASE-ZX extended distance; rugged\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"150\"\u003eGLC-BX40-U-I=\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"272\"\u003e1000BASE-BX40-U for 40km Single-Fiber Bidirectional Applications; with DOM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"150\"\u003eGLC-BX40-D-I=\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"272\"\u003e1000BASE-BX40-D for 40km Single-Fiber Bidirectional Applications; with DOM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"150\"\u003eGLC-BX40-DA-I=\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"272\"\u003e1000BASE-BX40-D (Alternative) for 40km Single-Fiber Bidirectional Applications; with DOM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"150\"\u003eGLC-BX80-U-I=\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"272\"\u003e1000BASE-BX80-U for 80km Single-Fiber Bidirectional Applications; with DOM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"150\"\u003eGLC-BX80-D-I=\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"272\"\u003e1000BASE-BX80-D for 80km Single-Fiber Bidirectional Applications; with DOM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"150\"\u003eGLC-SX-MMD=\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"272\"\u003e1000BASE-SX short wavelength; with DOM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"150\"\u003eGLC-LH-SMD=\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"272\"\u003e1000BASE-LX\/LH long-wavelength; with DOM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"150\"\u003eGLC-EX-SMD=\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"272\"\u003e1000BASE-EX long-wavelength; with DOM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"150\"\u003eGLC-ZX-SMD=\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"272\"\u003e1000BASE-ZX extended distance; with DOM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"150\"\u003eGLC-BX-D=\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"272\"\u003e1000BASE-BX10-D downstream bidirectional single fiber; with DOM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"150\"\u003eGLC-BX-U=\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"272\"\u003e1000BASE-BX10-U upstream bidirectional single fiber; with DOM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"150\"\u003eGLC-BX-D-I=\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"272\"\u003e1000BASE-BX10-D downstream bidirectional single fiber, (IND) rated, with DOM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"150\"\u003eGLC-BX-U-I=\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"272\"\u003e1000BASE-BX10-U upstream bidirectional single fiber, (IND) rated, with DOM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"150\"\u003eSFP-GE-S=\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"272\"\u003eCisco SFP-GE-S Duplex SFP 1Gbps 500m MMF DDM 850nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"150\"\u003eGLC-SX-MM=\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"272\"\u003eCisco GLCSXMM SFP, Duplex, 1Gbps, 500m, 7.5dB, MMF, 850nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"150\"\u003eGLC-TE=\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"272\"\u003e1000BASE-T standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"150\"\u003eGLC-T-RGD=\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"272\"\u003e1000BASE-T standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"150\"\u003eSFP-10G-BXD-I=\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"272\"\u003e10GBASE-BX10-D Bidirectional for 10km\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"150\"\u003eSFP-10G-BXU-I=\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"272\"\u003e10GBASE-BX10-U Bidirectional for 10km\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"150\"\u003eSFP-10G-BX40D-I=\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"272\"\u003e10GBASE-BX40-D Bidirectional for 40km\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"150\"\u003eSFP-10G-BX40U-I=\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"272\"\u003e10GBASE-BX40-U Bidirectional for 40km\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"150\"\u003eSFP-10G-SR-X=\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"272\"\u003eMultirate 10GBASE-SR, 10GBASE-SW and OTU2e SFP+ Module for MMF, extended temperature range\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"150\"\u003eSFP-10G-LR-X=\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"272\"\u003eMultirate 10GBASE-LR, 10GBASE-LW and OTU2e SFP+ Module for SMF, extended temperature range\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"150\"\u003eSFP-10G-SR=\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"272\"\u003e10GBASE-SR SFP+ Module for MMF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"150\"\u003eSFP-10G-LRM=\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"272\"\u003e10GBASE-LRM SFP+ Module for MMF and SMF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"150\"\u003eSFP-10G-LR=\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"272\"\u003e10GBASE-LR SFP+ Module for SMF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"150\"\u003eSFP-10G-ER=\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"272\"\u003e10GBASE-ER SFP+ Module for SMF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"150\"\u003eSFP-10G-ZR=\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"272\"\u003eMultirate 10GBASE-ZR, 10GBASE-ZW and OTU2e SFP+ Module for SMF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"150\"\u003eSFP-H10GB-CUxM=\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"272\"\u003e10GBASE-CU SFP+ Cable x Meter, passive\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"150\"\u003eSFP-10G-ER-I=\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"272\"\u003eMultirate 10GBASE-ER, 10GBASE-EW and OTU2e SFP+ Module for SMF, Industrial Temperature range\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"150\"\u003eSFP-10G-ZR-I=\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"272\"\u003eMultirate 10GBASE-ZR, 10GBASE-ZW and OTU2e SFP+ Module for SMF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"150\"\u003eCWDM-SFP10G-1470\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"272\"\u003eCisco CWDM 1470-nm SFP+; 10 Gigabit Ethernet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"150\"\u003eDWDM-SFP10G-30.33\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"272\"\u003e10GBASE-DWDM 1530.33 nm SFP+ (100-GHz ITU grid)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"150\"\u003eSFP-10G-LR-S\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"272\"\u003e10GBASE-LR SFP+ Module for SMF S-Class\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"150\"\u003eCWDM-SFP-1470\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"272\"\u003eCisco CWDM 1470-nm SFP; Gigabit Ethernet and 1 and 2 Gb Fibre Channel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"150\"\u003eCWDM-SFP-1610\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"272\"\u003eCisco CWDM 1610-nm SFP; Gigabit Ethernet and 1 and 2 Gb Fibre Channel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"150\"\u003eCWDM-SFP-1530\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"272\"\u003eCisco CWDM 1530-nm SFP; Gigabit Ethernet and 1 and 2-Gb Fibre Channel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"150\"\u003eCWDM-SFP-1490\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"272\"\u003eCisco CWDM 1490-nm SFP; Gigabit Ethernet and 1 and 2 Gb Fibre Channel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"150\"\u003eDWDM-SFP-3033\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"272\"\u003e1000BASE-DWDM 1530.33 nm SFP (100-GHz ITU grid)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"150\"\u003eDWDM-SFP-3112\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"272\"\u003e1000BASE-DWDM 1531.12 nm SFP (100-GHz ITU grid)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" width=\"422\" colspan=\"2\"\u003e*Supported only on Expansion modules with SFP downlink port option when paired with IE 3300 10G Uplinks Variants.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e[\/accesories]\u003c\/p\u003e\n\u003ch2\u003eCisco IE-3300-8U2X-E Industrial Ethernet Switch\u003c\/h2\u003e\n\u003cp\u003eThe Cisco IE-3300-8U2X-E is a high-performance industrial Ethernet switch designed to deliver reliable and secure network connectivity in harsh environments. This switch features 8 Gigabit Ethernet ports with Universal Power over Ethernet (UPOE\/4PPoE Type 3) support and 2 10-Gigabit SFP+ slots, making it an ideal solution for powering and connecting critical industrial devices such as IP cameras, sensors, and controllers. The IE-3300-8U2X-E is engineered to operate in extreme conditions, ensuring continuous operation while offering advanced Layer 2 and Layer 3 management features for effective network segmentation, security, and traffic control.\u003c\/p\u003e\n\u003ch3\u003eKey Features:\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e8 x Gigabit Ethernet Ports with UPOE:\u003c\/strong\u003e Provides reliable data connectivity while powering UPOE-enabled devices, simplifying installation and reducing the need for additional power supplies.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e2 x 10-Gigabit SFP+ Slots:\u003c\/strong\u003e Offers flexible uplink options with high-speed fiber connectivity, enabling enhanced data transfer rates and network scalability.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRuggedized Design:\u003c\/strong\u003e Built to withstand extreme temperatures, shock, and vibration, making it ideal for demanding industrial environments.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLayer 2 and Layer 3 Management:\u003c\/strong\u003e Includes advanced features such as VLANs, QoS, and routing protocols to enhance network control and security.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompact Form Factor:\u003c\/strong\u003e Designed for space-constrained installations, making it suitable for industrial enclosures and cabinets.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Overview:\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eRecommended for:\u003c\/strong\u003e Industrial environments requiring robust Ethernet connectivity with UPOE support and advanced management features.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePorts:\u003c\/strong\u003e 8 x Gigabit Ethernet ports with UPOE, 2 x 10-Gigabit SFP+ slots.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUPOE Budget:\u003c\/strong\u003e Supports up to 480W PoE budget (including expansion module).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e Designed to operate in a wide temperature range suitable for harsh industrial applications.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManagement:\u003c\/strong\u003e Managed through a web interface, CLI, SNMP, and Cisco Catalyst Center for comprehensive network setup and monitoring.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eForm Factor:\u003c\/strong\u003e Rugged, compact design suitable for space-constrained industrial environments.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eYou can check the related tab for the Cisco IE-3300-8U2X-E datasheet.\u003c\/p\u003e","brand":"Cisco","offers":[{"title":"Default Title","offer_id":48013129089241,"sku":"IE-3300-8U2X-E-NEW","price":5778.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0016\/5327\/6707\/files\/ie-3300-8u2x-e_1_b79d660c-2b4b-4004-af30-1a6110c2d8d7.webp?v=1771850453","url":"https:\/\/www.aloinfousa.com\/bn\/products\/cisco-ie-3300-8u2x-e-switch-f6hxi","provider":"aloinfousa.com","version":"1.0","type":"link"}