{"product_id":"dell-poweredge-r340-server-zssb1","title":"Dell PowerEdge R340 Server","description":"\u003cdiv class=\"head-content-set-outer\"\u003e\n\u003ch2 class=\"Dell_PowerEdge_R630_Specifications\"\u003eour Dell PowerEdge R340 Specifications\u003c\/h2\u003e\n\u003c!-- Chassis Section Order 1 --\u003e\n\u003cdiv class=\"head-content-set\"\u003e\n\u003ch3\u003eChassis\u003c\/h3\u003e\n\u003cdiv class=\"head-content-set-content\"\u003e\n\u003cp\u003eThe Dell PowerEdge R340 server is perfect for automation. This 1U rackmount server has two different chassis options to choose from: 4 Bay LFF and 8 Bay SFF.\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003e4 Bay LFF\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003eThe 4 Bay LFF chassis for the PowerEdge R340 supports up to four 3.5 SAS\/SATA drives. 2.5\" HDDs and SSDs can be plugged into the backplane via a 2.5\" to 3.5\" drive adapter. This chassis supports hot swap drives, meaning that drives can be installed or removed while the system is powered on. The rear of the chassis consist of one low-profile PCIe slot, one full-height PCIe slot, a serial connector, a VGA port, a dedicated iDRAC LAN port, two 1GbE RJ45 LAN ports, two type A USB 3.0 ports, and two hot-swap power supply bays.\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003e8 Bay SFF\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003eThe 8 Bay SFF chassis is nearly identical to the 4 Bay LFF chassis, however the 8 Bay SFF supports up to eight 2.5\" SAS\/SATA hard drives or solid-state drives. The rear of the 8 Bay SFF chassis is the exact same as the 4 Bay LFF, and includes one low-profile PCIe slot, one high-profile PCIe slot, a serial connector, a VGA port, a dedicated iDRAC LAN port, two 1GbE RJ45 LAN ports, two USB type A USB 3.0 ports, and two hot-swap power supply bays.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c!-- Processing Power Section Order 2 --\u003e\n\u003cdiv class=\"head-content-set\"\u003e\n\u003ch3\u003eProcessing Power\u003c\/h3\u003e\n\u003cdiv class=\"head-content-set-content\"\u003e\n\u003cp\u003eThe Dell PowerEdge R340 server has a single CPU socket that accepts Intel Xeon E-2100, Intel Xeon E-2200, Intel Pentium, Intel Core i3, or Intel Celeron processors. A maximum of 8 CPU cores are supported.\u003c\/p\u003e\n\u003cdiv class=\"outercontainerOfTwoTable\"\u003e\n\u003cdiv class=\"outercontainerOfOneTable\"\u003e\n\u003ch4 class=\"sub-title\"\u003eSupported Intel Xeon E-2100 Processors\u003c\/h4\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eCPU\u003c\/th\u003e\n\u003cth\u003eStep Code\u003c\/th\u003e\n\u003cth\u003eCores\u003c\/th\u003e\n\u003cth\u003eFrequency\u003c\/th\u003e\n\u003cth\u003eCache\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eE-2104G\u003c\/td\u003e\n\u003ctd\u003eSR3WV\u003c\/td\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003ctd\u003e3.2 GHz\u003c\/td\u003e\n\u003ctd\u003e8 MB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eE-2124\u003c\/td\u003e\n\u003ctd\u003eSR3WQ\u003c\/td\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003ctd\u003e3.3 GHz\u003c\/td\u003e\n\u003ctd\u003e8 MB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eE-2124G\u003c\/td\u003e\n\u003ctd\u003eSR3WL\u003c\/td\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003ctd\u003e3.4 GHz\u003c\/td\u003e\n\u003ctd\u003e8 MB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eE-2126G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e6\u003c\/td\u003e\n\u003ctd\u003e3.3 GHz\u003c\/td\u003e\n\u003ctd\u003e12 MB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eE-2134\u003c\/td\u003e\n\u003ctd\u003eSR3WP\u003c\/td\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003ctd\u003e3.5 GHz\u003c\/td\u003e\n\u003ctd\u003e8 MB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eE-2136\u003c\/td\u003e\n\u003ctd\u003eSR3WW\u003c\/td\u003e\n\u003ctd\u003e6\u003c\/td\u003e\n\u003ctd\u003e3.3 GHz\u003c\/td\u003e\n\u003ctd\u003e12 MB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eE-2144G\u003c\/td\u003e\n\u003ctd\u003eSR3WM\u003c\/td\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003ctd\u003e3.6 GHz\u003c\/td\u003e\n\u003ctd\u003e8 MB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eE-2146G\u003c\/td\u003e\n\u003ctd\u003eSR3WT\u003c\/td\u003e\n\u003ctd\u003e6\u003c\/td\u003e\n\u003ctd\u003e3.5 GHz\u003c\/td\u003e\n\u003ctd\u003e12 MB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eE-2174G\u003c\/td\u003e\n\u003ctd\u003eSR3WN\u003c\/td\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003ctd\u003e3.8 GHz\u003c\/td\u003e\n\u003ctd\u003e8 MB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eE-2176G\u003c\/td\u003e\n\u003ctd\u003eSR3WS\u003c\/td\u003e\n\u003ctd\u003e6\u003c\/td\u003e\n\u003ctd\u003e3.7 GHz\u003c\/td\u003e\n\u003ctd\u003e12 MB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eE-2186G\u003c\/td\u003e\n\u003ctd\u003eSR3WR\u003c\/td\u003e\n\u003ctd\u003e6\u003c\/td\u003e\n\u003ctd\u003e3.8 GHz\u003c\/td\u003e\n\u003ctd\u003e12 MB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"outercontainerOfOneTable\"\u003e\n\u003ch4 class=\"sub-title\"\u003eSupported Intel Xeon E-2200 Processors\u003c\/h4\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eCPU\u003c\/th\u003e\n\u003cth\u003eStep Code\u003c\/th\u003e\n\u003cth\u003eCores\u003c\/th\u003e\n\u003cth\u003eFrequency\u003c\/th\u003e\n\u003cth\u003eCache\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eE-2224\u003c\/td\u003e\n\u003ctd\u003eSRFAV\u003c\/td\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003ctd\u003e3.4 GHz\u003c\/td\u003e\n\u003ctd\u003e8 MB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eE-2224G\u003c\/td\u003e\n\u003ctd\u003eSRFAW\u003c\/td\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003ctd\u003e3.5 GHz\u003c\/td\u003e\n\u003ctd\u003e8 MB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eE-2226G\u003c\/td\u003e\n\u003ctd\u003eSRF7F\u003c\/td\u003e\n\u003ctd\u003e6\u003c\/td\u003e\n\u003ctd\u003e3.4 GHz\u003c\/td\u003e\n\u003ctd\u003e12 MB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eE-2234\u003c\/td\u003e\n\u003ctd\u003eSRFAX\u003c\/td\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003ctd\u003e3.6 GHz\u003c\/td\u003e\n\u003ctd\u003e8 MB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eE-2236\u003c\/td\u003e\n\u003ctd\u003eSRF7G\u003c\/td\u003e\n\u003ctd\u003e6\u003c\/td\u003e\n\u003ctd\u003e3.4 GHz\u003c\/td\u003e\n\u003ctd\u003e12 MB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eE-2244G\u003c\/td\u003e\n\u003ctd\u003eSRFAY\u003c\/td\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003ctd\u003e3.8 GHz\u003c\/td\u003e\n\u003ctd\u003e8 MB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eE-2246G\u003c\/td\u003e\n\u003ctd\u003eSRF7N\u003c\/td\u003e\n\u003ctd\u003e6\u003c\/td\u003e\n\u003ctd\u003e3.6 GHz\u003c\/td\u003e\n\u003ctd\u003e12 MB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eE-2274G\u003c\/td\u003e\n\u003ctd\u003eSRFDE\u003c\/td\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003ctd\u003e4.0 GHz\u003c\/td\u003e\n\u003ctd\u003e8 MB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eE-2276G\u003c\/td\u003e\n\u003ctd\u003eSRF7M\u003c\/td\u003e\n\u003ctd\u003e6\u003c\/td\u003e\n\u003ctd\u003e3.8 GHz\u003c\/td\u003e\n\u003ctd\u003e12 MB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eE-2278G\u003c\/td\u003e\n\u003ctd\u003eSRFB2\u003c\/td\u003e\n\u003ctd\u003e8\u003c\/td\u003e\n\u003ctd\u003e3.4 GHz\u003c\/td\u003e\n\u003ctd\u003e16 MB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eE-2286G\u003c\/td\u003e\n\u003ctd\u003eSRF7C\u003c\/td\u003e\n\u003ctd\u003e6\u003c\/td\u003e\n\u003ctd\u003e4.0 GHz\u003c\/td\u003e\n\u003ctd\u003e12 MB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eE-2288G\u003c\/td\u003e\n\u003ctd\u003eSRFB3\u003c\/td\u003e\n\u003ctd\u003e8\u003c\/td\u003e\n\u003ctd\u003e3.7 GHz\u003c\/td\u003e\n\u003ctd\u003e16 MB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"outercontainerOfTwoTable\"\u003e\n\u003cdiv class=\"outercontainerOfOneTable\"\u003e\n\u003ch4 class=\"sub-title\"\u003eSupported Intel Core i3 Processors\u003c\/h4\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eCPU\u003c\/th\u003e\n\u003cth\u003eStep Code\u003c\/th\u003e\n\u003cth\u003eCores\u003c\/th\u003e\n\u003cth\u003eFrequency\u003c\/th\u003e\n\u003cth\u003eCache\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003ei3-8100\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003ctd\u003e3.6 GHz\u003c\/td\u003e\n\u003ctd\u003e6 MB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ei3-9100\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003ctd\u003e3.60 GHz\u003c\/td\u003e\n\u003ctd\u003e6 MB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"outercontainerOfOneTable\"\u003e\n\u003ch4 class=\"sub-title\"\u003eSupported Intel Celeron\/Pentium Processors\u003c\/h4\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eCPU\u003c\/th\u003e\n\u003cth\u003eStep Code\u003c\/th\u003e\n\u003cth\u003eCores\u003c\/th\u003e\n\u003cth\u003eFrequency\u003c\/th\u003e\n\u003cth\u003eCache\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eCeleron G4900\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003ctd\u003e3.10 GHz\u003c\/td\u003e\n\u003ctd\u003e2 MB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCeleron G4930\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003ctd\u003e3.20 GHz\u003c\/td\u003e\n\u003ctd\u003e2 MB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePentium G5420\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003ctd\u003e3.80 GHz\u003c\/td\u003e\n\u003ctd\u003e4 MB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePentium G5500\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003ctd\u003e3.80 GHz\u003c\/td\u003e\n\u003ctd\u003e4 MB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c!-- Memory Section Order 3 --\u003e\n\u003cdiv class=\"head-content-set\"\u003e\n\u003ch3\u003eMemory\u003c\/h3\u003e\n\u003cdiv class=\"head-content-set-content\"\u003e\n\u003ch4\u003e\u003cstrong\u003eDIMM Slots \u0026amp; Channels\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003eThe Dell PowerEdge R340 Server has a total of 4 DIMM slots. There is a total of two memory channels, each consisting of two DIMM slots.\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eMemory Types \u0026amp; Module Capacities\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003eThis system accepts DDR4 memory. ECC Unbuffered (ECC UDIMM) memory is the only type of memory that can be used with the R340. Capacities of 4GB, 8GB, and 16GB can be used with the PowerEdge R340.\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eMax Configurations\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003eThe R340 server allows for a maximum memory configuration of 64GB with 4x16GB ECC UDIMMs.\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSupported Memory Speeds\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003eThe Dell R340 supports memory speeds of 2133MT\/s, 2400MT\/s, 2666MT\/s. The processor you have installed will determine the max memory speed that you can use with your system. For example, if your processor supports a max memory speed off 2400MT\/s and you install a 2666MT\/s module, the module will clock down to 2400MT\/s. 2666MT\/s is the fastest possible speed for this system.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c!-- Storage Section Order 4 --\u003e\n\u003cdiv class=\"head-content-set\"\u003e\n\u003ch3\u003eStorage\u003c\/h3\u003e\n\u003cdiv class=\"head-content-set-content\"\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4 class=\"sub-title\"\u003e\u003cstrong\u003eSupported Drives (2.5”) \u003c\/strong\u003e\u003c\/h4\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eType\u003c\/th\u003e\n\u003cth\u003eSpeeds\u003c\/th\u003e\n\u003cth\u003eMax Capacity (Per Drive)\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSAS\u003c\/td\u003e\n\u003ctd\u003e7.2K, 10K, 15K\u003c\/td\u003e\n\u003ctd\u003e2.4TB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSATA\u003c\/td\u003e\n\u003ctd\u003e7.2K\u003c\/td\u003e\n\u003ctd\u003e2TB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSSD\u003c\/td\u003e\n\u003ctd\u003e6Gb\/s, 12Gb\/s\u003c\/td\u003e\n\u003ctd\u003e7.68TB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"head-content-set-content\"\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4 class=\"sub-title\"\u003e\u003cstrong\u003eSupported Drives (3.5\")\u003c\/strong\u003e\u003c\/h4\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eType\u003c\/th\u003e\n\u003cth\u003eSpeeds\u003c\/th\u003e\n\u003cth\u003eMax Capacity (Per Drive)\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSAS\u003c\/td\u003e\n\u003ctd\u003e7.2K\u003c\/td\u003e\n\u003ctd\u003e18TB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSATA\u003c\/td\u003e\n\u003ctd\u003e7.2K\u003c\/td\u003e\n\u003ctd\u003e16TB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSSD\u003c\/td\u003e\n\u003ctd\u003e6Gb\/s, 12Gb\/s\u003c\/td\u003e\n\u003ctd\u003e7.68TB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c!-- Storage Section Order 4 --\u003e \u003c!--\u003cdiv class=\"head-content-set\"\u003e\n \u003ch3\u003e\u003cspan data-mce-fragment=\"1\"\u003eNVMe Options \u0026amp; Upgrades\u003c\/span\u003e\u003c\/h3\u003e\n \u003cdiv class=\"head-content-set-content\"\u003e\n \u003cp\u003e\n \n \u003c\/p\u003e\n \u003ch4\u003e\u003cstrong\u003eU.2 NVMe\u003c\/strong\u003e\u003c\/h4\u003e\n \u003cp\u003e\n \n \u003c\/p\u003e\n \u003ch4\u003e\u003cstrong\u003ePCIe NVMe\u003c\/strong\u003e\u003c\/h4\u003e\n \u003cp\u003e\n \n \u003c\/p\u003e\n \u003ch4\u003e\u003cstrong\u003eM.2 NVMe\u003c\/strong\u003e\u003c\/h4\u003e\n \u003cp\u003e\n \n \u003c\/p\u003e\n \u003c\/div\u003e\n \u003c\/div\u003e--\u003e \u003c!-- Systems Management Solutions Section Order 7 --\u003e\n\u003cdiv class=\"head-content-set\"\u003e\n\u003ch3\u003ePower Supplies\u003c\/h3\u003e\n\u003cdiv class=\"head-content-set-content\"\u003e\n\u003ch4\u003e\u003cstrong\u003eHow Many Power Supplies does the R340 Support?\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003eThe PowerEdge R340 server supports up to two hot-swap power supply units (PSUs). Hot-swap means that PSUs can be removed or added while the system is powered on as long a one unit remains plugged in the system.\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003ePower Supply Options\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003eThere are two power supply options for the PowerEdge R340: Platinum 350W and Platinum 550W. For higher-end applications, it is best to go with the 550W option. For lower-end applications, the 350W option is fine.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c!-- Storage Section Order 5 --\u003e\n\u003cdiv class=\"head-content-set\"\u003e\n\u003ch3\u003eRAID Options\u003c\/h3\u003e\n\u003cdiv class=\"head-content-set-content\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eRAID Options\u003c\/th\u003e\n\u003cth\u003eRAID Levels\u003c\/th\u003e\n\u003cth\u003eCache\u003c\/th\u003e\n\u003cth\u003eDrive Speeds\u003c\/th\u003e\n\u003cth\u003ePCIe Generation\u003c\/th\u003e\n\u003cth\u003eRAID Hardware\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eS140 onboard software\u003c\/td\u003e\n\u003ctd\u003e0,1,5,10\u003c\/td\u003e\n\u003ctd\u003eNone\u003c\/td\u003e\n\u003ctd\u003e6 Gb\/s SATA\/NVMe\u003c\/td\u003e\n\u003ctd\u003eN\/A\u003c\/td\u003e\n\u003ctd\u003eSoftware\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHBA330\u003c\/td\u003e\n\u003ctd\u003ePassthrough\u003c\/td\u003e\n\u003ctd\u003eNone\u003c\/td\u003e\n\u003ctd\u003e6 Gb\/s SAS\/SATA\u003cbr\u003e12 Gb\/s SAS\u003c\/td\u003e\n\u003ctd\u003ePCIe 3.0\u003c\/td\u003e\n\u003ctd\u003eHardware\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e12Gbps SAS Ext. HBA\u003c\/td\u003e\n\u003ctd\u003ePassthrough\u003c\/td\u003e\n\u003ctd\u003eNone\u003c\/td\u003e\n\u003ctd\u003e12 Gb\/s SAS\u003c\/td\u003e\n\u003ctd\u003ePCIe 3.0\u003c\/td\u003e\n\u003ctd\u003eHardware\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eH330\u003c\/td\u003e\n\u003ctd\u003e0, 1, 5, 10, 50\u003c\/td\u003e\n\u003ctd\u003eNone\u003c\/td\u003e\n\u003ctd\u003e6 Gb\/s SATA\u003cbr\u003e12 Gb\/s SAS\u003c\/td\u003e\n\u003ctd\u003ePCIe 3.0\u003c\/td\u003e\n\u003ctd\u003eHardware\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eH730P\u003c\/td\u003e\n\u003ctd\u003e0, 1, 5, 6, 10, 50, 60\u003c\/td\u003e\n\u003ctd\u003e2 GB NV\u003c\/td\u003e\n\u003ctd\u003e6 Gb\/s SATA\u003cbr\u003e12 Gb\/s SAS\u003c\/td\u003e\n\u003ctd\u003ePCIe 3.0\u003c\/td\u003e\n\u003ctd\u003eHardware\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c!-- Network Interface Card Options Section Order 6 --\u003e\n \u003cdiv class=\"head-content-set\"\u003e\n \u003ch3\u003eNetwork Interface Card Options\u003c\/h3\u003e\n \u003cdiv class=\"head-content-set-content\"\u003e\n \u003cdiv class=\"outercontainerOfTwoTable\"\u003e\n \u003cdiv class=\"outercontainerOfOneTable\"\u003e\n \u003ch4 class=\"sub-title\"\u003eDaughter Cards\u003c\/h4\u003e\n \u003ctable\u003e\n \u003ctbody\u003e\n \u003ctr\u003e\n \u003ctd\u003eBroadcom 5720\/57412 Quad Port 2x1GbE RJ45 + 2x10GbE SFP+\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003ctd\u003eBroadcom 5720 Quad Port 4x1GbE RJ45\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003ctd\u003eBroadcom 57414 Dual Port 2x10\/25GbE SFP28\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003ctd\u003e\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003ctd\u003eIntel i350\/X550 Quad Port 2x1GbE RJ45 + 2x10GbE RJ45\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003ctd\u003eIntel X550 Quad Port 4x10GbE RJ45\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003ctd\u003eIntel X710 Quad Port 4x10GbE SFP+\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003ctd\u003e\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003ctd\u003eMellanox ConnectX-4 Lx Dual Port 10\/25GbE SFP28 V2\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003ctd\u003eMellanox ConnectX-4 Lx Dual Port 10\/25GbE SFP28\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003c\/tbody\u003e\n \u003c\/table\u003e\n \u003c\/div\u003e\n \u003cdiv class=\"outercontainerOfOneTable\"\u003e\n \u003ch4 class=\"sub-title\"\u003ePCIe Cards\u003c\/h4\u003e\n \u003ctable\u003e\n \u003ctbody\u003e\n \u003ctr\u003e\n \u003ctd\u003eBroadcom 5719 Quad Port 4x1GbE RJ45\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003ctd\u003eBroadcom 5720 Dual Port 2x1GbE RJ45\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003ctd\u003eBroadcom 57412 Dual Port 2x10GbE SFP+\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003ctd\u003eBroadcom 57414 Dual Port 2x10\/25GbE SFP28\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003ctd\u003eBroadcom 57416 Dual Port 2x10GbE RJ45\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003ctd\u003eBroadcom 57508 Dual Port 2x100GbE QSFP\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003ctd\u003e\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003ctd\u003eIntel X550 Dual Port 2x10GbE RJ45\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003ctd\u003eIntel X710-T2L Dual Port 2x10GbE RJ45\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003ctd\u003eIntel X710-T4L Quad Port 4x10GbE RJ45\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003ctd\u003eIntel E810-XXV Dual Port 2x10\/25GbE SFP28\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003ctd\u003e\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003ctd\u003eMellanox ConnectX-4 LX Dual Port 2x10\/25GbE SFP28 V2\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003ctd\u003eMellanox ConnectX-4 LX Dual Port 2x10\/25GbE SFP28\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003ctd\u003eMellanox ConnectX-5 Dual Port 2x10\/25GbE SFP28 V2\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003ctd\u003e\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003ctd\u003eEmulex LPE 35002 Dual Port 2x32Gb FC HBA\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003ctd\u003eEmulex LPE 35000 Single Port 1x32Gb FC HBA\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003ctd\u003eEmulex LPe31002 Dual Port 2x16Gb FC HBA V2\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003ctd\u003eEmulex LPe31000 Single Port 1x16Gb FC HBA V2\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003ctd\u003e\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003ctd\u003eQLogic 2690 Single Port 1x16Gb FC HBA V2\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003ctd\u003eQLogic 2772 Dual Port 2x32Gb FC HBA V2\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003c\/tbody\u003e\n \u003c\/table\u003e\n \u003c\/div\u003e\n \u003c\/div\u003e\n \u003c\/div\u003e\n \u003c\/div\u003e\n \u003c!-- Systems Management Solutions Section Order 7 --\u003e\n\u003cdiv class=\"head-content-set\"\u003e\n\u003ch3\u003eSystems Management Solutions\u003c\/h3\u003e\n\u003cp class=\"head-content-set-content\"\u003eThe Dell PowerEdge R340 Server utilizes the Integrated Dell Remote Access Controller 9 (iDRAC9), which allows you to easily manage your Dell server. The iDRAC9 web interface provides a variety of useful information and features, that make managing your Dell server an easy task. Features include, but are not limited to hardware monitoring, power control, remote console, control over system settings, firmware update control, storage management, and much more. You can access the iDRAC9 web interface, by setting the iDRAC IP in system setup, and searching the IP in a web browser.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c!-- Systems Management Solutions Section Order 8 --\u003e\n\u003cdiv class=\"head-content-set\"\u003e\n\u003ch3\u003eSupported Operating Systems:\u003c\/h3\u003e\n\u003cp class=\"head-content-set-content\"\u003eThe PowerEdge R340 supports a wide variety of operating systems which ranges from different distributions of Linux, VMware, and Windows Server. These operating systems are:\u003c\/p\u003e\n\u003cul class=\"custom_dots\"\u003e\n\u003cli\u003e⦿ Citrix XenServer 7.1\u003c\/li\u003e\n\u003cli\u003e⦿ Red Hat® Enterprise Linux 7\u003c\/li\u003e\n\u003cli\u003e⦿ Red Hat® Enterprise Linux 8\u003c\/li\u003e\n\u003cli\u003e⦿ Red Hat® Enterprise Linux 9\u003c\/li\u003e\n\u003cli\u003e⦿ SUSE Linux ES 15\u003c\/li\u003e\n\u003cli\u003e⦿ Ubuntu Server 18.04 LTS\u003c\/li\u003e\n\u003cli\u003e⦿ Ubuntu Server 20.04 LTS\u003c\/li\u003e\n\u003cli\u003e⦿ VMware ESXi 6.5\u003c\/li\u003e\n\u003cli\u003e⦿ VMware ESXi 6.7\u003c\/li\u003e\n\u003cli\u003e⦿ VMware ESXi 7.0\u003c\/li\u003e\n\u003cli\u003e⦿ VMware ESXi 8.0\u003c\/li\u003e\n\u003cli\u003e⦿ Window Server 2012 R2\u003c\/li\u003e\n\u003cli\u003e⦿ Window Server 2016\u003c\/li\u003e\n\u003cli\u003e⦿ Window Server 2019 LTSC\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\n\u003c\/div\u003e","brand":"Dell","offers":[{"title":"4 Bay LFF","offer_id":49102946107609,"sku":"Dell-R340-4B-LFF","price":769.49,"currency_code":"USD","in_stock":true},{"title":"8 Bay SFF","offer_id":49102946140377,"sku":"Dell-R340-8B-SFF","price":755.99,"currency_code":"USD","in_stock":true}],"url":"https:\/\/www.aloinfousa.com\/es-br\/products\/dell-poweredge-r340-server-zssb1","provider":"aloinfousa.com","version":"1.0","type":"link"}