{"product_id":"150-c60nbd-allen-bradley-smc-3-smart-motor-controller","title":"150-C60NBD | Allen-Bradley SMC-3 Smart Motor Controller","description":"\u003ch4\u003eDescription \u003c\/h4\u003e\n\u003cp data-end=\"451\" data-start=\"0\"\u003eThe Allen-Bradley 150-C60NBD is an SMC-3 Smart Motor Controller designed for 3-phase motor control applications requiring dependable soft-start functionality. Operating on a 480 V AC power system with a maximum operating current of 60 A, it provides controlled motor acceleration and deceleration for improved system performance. With a wide control voltage range of 100–240 V AC, the controller integrates easily into diverse industrial control architectures.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications \u003c\/h4\u003e\n\u003ctable style=\"width: 100%;\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 37.8496%;\"\u003e\u003cstrong\u003eCondition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.9311%;\"\u003eNew\/Never Used Surplus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 37.8496%;\"\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.9311%;\"\u003eAllen-Bradley\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 37.8496%;\"\u003e\u003cstrong\u003eCategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.9311%;\"\u003eDrives\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 37.8496%;\"\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.9311%;\"\u003e150-C60NBD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 37.8496%;\"\u003e\u003cstrong\u003eSubcategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.9311%;\"\u003eSoft Start\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 37.8496%;\"\u003e\u003cstrong\u003eVoltage Type for Actuating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.9311%;\"\u003eAC\/DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 37.8496%;\"\u003e\u003cstrong\u003eRated Operating Voltage (Ue)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.9311%;\"\u003e200 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 37.8496%;\"\u003e\u003cstrong\u003eRated Control Supply Voltage @ 50 Hz\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.9311%;\"\u003e100 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 37.8496%;\"\u003e\u003cstrong\u003eRated Control Supply Voltage @ 60 Hz\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.9311%;\"\u003e100 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 37.8496%;\"\u003e\u003cstrong\u003eOverload Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.9311%;\"\u003e20 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 37.8496%;\"\u003e\u003cstrong\u003eController Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.9311%;\"\u003eSMC-3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 37.8496%;\"\u003e\u003cstrong\u003eDV\/DT Protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.9311%;\"\u003e1000 V\/µs (power circuit)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 37.8496%;\"\u003e\u003cstrong\u003eRepetitive Peak Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.9311%;\"\u003e1400 V (UL\/CSA\/NEMA)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 37.8496%;\"\u003e\u003cstrong\u003eOperating Frequency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.9311%;\"\u003e50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 37.8496%;\"\u003e\u003cstrong\u003eLine-Connected Motor Power (Max)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.9311%;\"\u003e7.5–20 HP @ 230 V AC (60 Hz), 3-phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 37.8496%;\"\u003e\u003cstrong\u003eDelta-Connected Motor Power (Max)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.9311%;\"\u003e7.5–30 kW @ 230 V AC (50 Hz), 3-phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 37.8496%;\"\u003e\u003cstrong\u003eOvervoltage Category\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.9311%;\"\u003eIII (side-mount auxiliary contacts)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 37.8496%;\"\u003e\u003cstrong\u003eRated Impulse Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.9311%;\"\u003e6 kV (power circuit)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 37.8496%;\"\u003e\u003cstrong\u003eDielectric Withstand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.9311%;\"\u003e2500 V AC (power circuit)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 37.8496%;\"\u003e\u003cstrong\u003eLine-Connected Motor Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.9311%;\"\u003e20–60 A @ 380–460 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 37.8496%;\"\u003e\u003cstrong\u003eDelta-Connected Motor Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.9311%;\"\u003e34.6–104 A @ 380–460 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 37.8496%;\"\u003e\u003cstrong\u003eInsulation Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.9311%;\"\u003e600 V AC (UL\/CSA\/NEMA)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 37.8496%;\"\u003e\u003cstrong\u003eRated Operational Voltage (Aux Contacts)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.9311%;\"\u003e250 V AC \/ 30 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 37.8496%;\"\u003e\u003cstrong\u003eRated Control Power During Start (Fan)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.9311%;\"\u003e200 mA @ 120 V AC \/ 100 mA @ 240 V AC \/ 700 mA @ 24 V AC\/DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 37.8496%;\"\u003e\u003cstrong\u003eInput OFF-State Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.9311%;\"\u003e\u0026lt;10–12 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 37.8496%;\"\u003e\u003cstrong\u003eSCPD List\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.9311%;\"\u003eNon-time delay, Thermal magnetic, Class CC\/J\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 37.8496%;\"\u003e\u003cstrong\u003eNumber of Contacts (Aux\/Fault)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.9311%;\"\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 37.8496%;\"\u003e\u003cstrong\u003eFault Current Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.9311%;\"\u003e70 kA @ 600 V (Class J\/L fuse)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 37.8496%;\"\u003e\u003cstrong\u003eAux Contact Current (Ith)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.9311%;\"\u003e1 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 37.8496%;\"\u003e\u003cstrong\u003eAux Contact Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.9311%;\"\u003eN.O. (electromagnetic relay)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 37.8496%;\"\u003e\u003cstrong\u003eUtilization Category\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.9311%;\"\u003eC300\/R150\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 37.8496%;\"\u003e\u003cstrong\u003eRated Operational Current (Aux Contacts)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.9311%;\"\u003e0.6 A @ 120 V AC \/ 0.3 A @ 240 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 37.8496%;\"\u003e\u003cstrong\u003eStandard Controller Feature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.9311%;\"\u003eSoft stop\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 37.8496%;\"\u003e\u003cstrong\u003eStandard Fault Current Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.9311%;\"\u003e10 kA (max standard fuse 400 A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 37.8496%;\"\u003e\u003cstrong\u003eIntegrated Overload Protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.9311%;\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 37.8496%;\"\u003e\u003cstrong\u003eSCPD Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.9311%;\"\u003eType 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 37.8496%;\"\u003e\u003cstrong\u003eSelectable Overload Trip Class\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.9311%;\"\u003e10 \/ 15 \/ 20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 37.8496%;\"\u003e\u003cstrong\u003eSelectable Start Times\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.9311%;\"\u003e2, 5, 10, 15, 20, 25, 30 s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 37.8496%;\"\u003e\u003cstrong\u003eInput OFF-State Voltage (Max)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.9311%;\"\u003e40 V AC \/ 17 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 37.8496%;\"\u003e\u003cstrong\u003eSelectable Current Limit\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.9311%;\"\u003e150%, 250%, 350%, 450% of FLA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 37.8496%;\"\u003e\u003cstrong\u003eInput ON-State Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.9311%;\"\u003eMin 85 V AC \/ 19.2 V AC\/DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 37.8496%;\"\u003e\u003cstrong\u003eInput ON-State Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.9311%;\"\u003e9.8 mA @ 120 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003eInformation About 150-C60NBD\u003c\/h4\u003e\n\u003cp class=\"\" data-end=\"1074\" data-start=\"590\"\u003eThe 150-C60NBD is part of the Allen-Bradley SMC-3 series, a family of compact, solid-state motor controllers engineered for reliable soft-start and soft-stop operation. Its open-type construction and 3-wire configuration support straightforward installation while providing access for maintenance and system monitoring. Designed to handle demanding motor loads, it includes integrated overload protection, configurable trip classes, and selectable current limits to match application-specific requirements. This controller is commonly used in industrial equipment, pumping stations, and material-handling systems where controlled motor starting, reduced mechanical stress, and long-term durability are essential.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong data-end=\"1102\" data-start=\"1085\"\u003eKey Features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e60 A motor controller: Supports a wide range of 3-phase motor sizes.\u003c\/li\u003e\n\u003cli\u003e480 V AC operation: Designed for standard industrial power systems.\u003c\/li\u003e\n\u003cli\u003eWide control voltage range: Accepts 100–240 V AC for flexible integration.\u003c\/li\u003e\n\u003cli\u003eSMC-3 functionality: Provides soft start, soft stop, and current limiting.\u003c\/li\u003e\n\u003cli\u003eIntegrated motor overload protection: Includes selectable trip classes 10, 15, and 20.\u003c\/li\u003e\n\u003cli\u003eHigh voltage endurance: Rated 1400 V repetitive peak and 6 kV impulse withstand per UL\/IEC.\u003c\/li\u003e\n\u003cli\u003eAdjustable start times: Allows selection from 2 to 30 seconds.\u003c\/li\u003e\n\u003cli\u003eRobust fault handling: Supports auxiliary fault contacts and compatible SCPD protection devices.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe 150-C60NBD delivers the reliability and precision required for controlled motor starting and protection in demanding industrial applications.\u003c\/p\u003e\n\u003cul\u003e\u003c\/ul\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":51071507562713,"sku":"150-C60NBD","price":2954.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0016\/5327\/6707\/files\/shopping-2024-02-11T222702.648.webp?v=1793441138","url":"https:\/\/www.aloinfousa.com\/es\/products\/150-c60nbd-allen-bradley-smc-3-smart-motor-controller","provider":"aloinfousa.com","version":"1.0","type":"link"}