{"product_id":"broadcom-bcm957508-p2100g-dual-port-100gbe-network-interface-card-kwnno","title":"Broadcom BCM957508-P2100G Dual-Port 100GbE Network Interface Card","description":"\u003cp\u003e[shortdesc] Dual-port 100GbE QSFP56, PCIe 4.0 x16, Broadcom BCM57508 controller, SR-IOV up to 1K VFs, RoCE support, Standard and low-profile brackets [\/shortdesc]\u003c\/p\u003e\n\u003cp\u003e[properties]\u003c\/p\u003e\n\u003ctable border=\"0\" cellpadding=\"0\" cellspacing=\"0\" width=\"512\" style=\"border-collapse: collapse; width: 512px;\"\u003e\n\u003ccolgroup\u003e \u003ccol width=\"172\" style=\"width: 172px;\"\u003e \u003ccol width=\"340\" style=\"width: 340px;\"\u003e \u003c\/colgroup\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eBroadcom\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003eBCM957508-P2100G\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eP2100G\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eEthernet Network Interface Card (NIC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePorts\u003c\/td\u003e\n\u003ctd\u003eDual-port\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePort Speed\u003c\/td\u003e\n\u003ctd\u003e100 Gb\/s per port\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnector Type\u003c\/td\u003e\n\u003ctd\u003eQSFP56\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupported Media\u003c\/td\u003e\n\u003ctd\u003eQSFP56\/QSFP28\/QSFP+ optical modules; copper direct-attach cables\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHost Interface\u003c\/td\u003e\n\u003ctd\u003ePCI Express 4.0 x16\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eController\u003c\/td\u003e\n\u003ctd\u003eBroadcom BCM57508 200GbE MAC controller\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTransceiver\u003c\/td\u003e\n\u003ctd\u003eIntegrated dual-channel 100GbE SFI transceiver\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSignaling Support\u003c\/td\u003e\n\u003ctd\u003e50G PAM-4, 25G NRZ, 10G NRZ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSR-IOV\u003c\/td\u003e\n\u003ctd\u003eUp to 1k virtual functions (VFs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eJumbo Frames\u003c\/td\u003e\n\u003ctd\u003eUp to 9 KB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNetwork Boot\u003c\/td\u003e\n\u003ctd\u003ePXE, UEFI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eiSCSI Boot\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRDMA Support\u003c\/td\u003e\n\u003ctd\u003eRDMA over Converged Ethernet (RoCE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDCB Support\u003c\/td\u003e\n\u003ctd\u003ePFC, ETS, QCN, DCBx\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVirtualization Offloads\u003c\/td\u003e\n\u003ctd\u003eVXLAN, NVGRE, Geneve, GRE encap\/decap\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eForm Factor\u003c\/td\u003e\n\u003ctd\u003ePCIe Low Profile, Half Length\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBracket\u003c\/td\u003e\n\u003ctd\u003eStandard and Low-Profile brackets included\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBoard Dimensions (W x H\u003c\/td\u003e\n\u003ctd\u003e167.64 mm x 68.91 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e167 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e0 to 55 Celsius\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e-40 to 70 Celsius\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Humidity\u003c\/td\u003e\n\u003ctd\u003eMaximum 90% at 35 Celsius (non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption (Typical\u003c\/td\u003e\n\u003ctd\u003e16.0W (Passive DAC, 21.0W (Optical Transceiver\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption (Max\u003c\/td\u003e\n\u003ctd\u003e17.1W (Passive DAC, 22.0W (Optical Transceiver\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e[\/properties]\u003c\/p\u003e\n\u003cp\u003e[specifications]\u003c\/p\u003e\n\u003ctable border=\"0\" cellpadding=\"0\" cellspacing=\"0\" width=\"512\" style=\"border-collapse: collapse; width: 512px;\"\u003e\n\u003ccolgroup\u003e \u003ccol width=\"172\" style=\"width: 172px;\"\u003e \u003ccol width=\"340\" style=\"width: 340px;\"\u003e \u003c\/colgroup\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eMedia Interface\u003c\/td\u003e\n\u003ctd\u003eDual-port pluggable media interface compatible with QSFP56\/QSFP28\/QSFP+ optical transceiver or copper direct-attach cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePCIe Compliance\u003c\/td\u003e\n\u003ctd\u003ePCI Express Base Specification Revision 4.0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePCIe Lane Width\u003c\/td\u003e\n\u003ctd\u003ex16\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMulti-Host Support\u003c\/td\u003e\n\u003ctd\u003eDual-Host x8 mode signaling compatible\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandards Compliance\u003c\/td\u003e\n\u003ctd\u003eFully compliant with SFF-8402\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOffloads\u003c\/td\u003e\n\u003ctd\u003eIPv4 and IPv6 offloads; TCP, UDP, and IP checksum offloads\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLarge Packet Offloads\u003c\/td\u003e\n\u003ctd\u003eLSO, LRO, TSO\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eScaling\u003c\/td\u003e\n\u003ctd\u003eRSS, TSS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVLAN\u003c\/td\u003e\n\u003ctd\u003eVLAN insertion\/removal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInterrupts\u003c\/td\u003e\n\u003ctd\u003eInterrupt coalescing; MSI and MSI-X\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVirtual Switching\u003c\/td\u003e\n\u003ctd\u003evSwitch acceleration; tunnel-aware stateless offloads\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFlow Processing\u003c\/td\u003e\n\u003ctd\u003eTruFlow flow processing engine\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCongestion Management\u003c\/td\u003e\n\u003ctd\u003eAdvanced congestion avoidance\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eQueue Features\u003c\/td\u003e\n\u003ctd\u003eMultiqueue, NetQueue, VMQ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSideband Management\u003c\/td\u003e\n\u003ctd\u003eNetwork Controller Sideband Interface (NC-SI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManagement Transport\u003c\/td\u003e\n\u003ctd\u003eMCTP over SMBus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSMBus\u003c\/td\u003e\n\u003ctd\u003eSMBus 2.0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFunction-Level Reset\u003c\/td\u003e\n\u003ctd\u003eFLR support\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFRU\u003c\/td\u003e\n\u003ctd\u003eFRU support\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAirflow Requirement (Hot Aisle\u003c\/td\u003e\n\u003ctd\u003e225 LFM (Passive DAC, 420 LFM (Optical Transceiver\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmbient Temperature (Hot Aisle\u003c\/td\u003e\n\u003ctd\u003e55 Celsius\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRegulatory Approvals\u003c\/td\u003e\n\u003ctd\u003eCE\/European Union EN 62368-1:2014; UL\/USA IEC 62368-1 (ed. 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEMC Compliance\u003c\/td\u003e\n\u003ctd\u003eEN 55032 Class A; EN 55024; EN 61000-3-2; EN 61000-3-3; FCC CFR47 Part 15 Subpart B Class A; ICES-003 Class A; AS\/NZS CISPR 22 Class A; CNS 13438 Class A; CNS 15663\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eESD Compliance\u003c\/td\u003e\n\u003ctd\u003eEN55035 (EN 61000-4-2 Air\/Direct discharge\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e[\/specifications]\u003c\/p\u003e\n\u003cp\u003e[accesories]\u003c\/p\u003e\n\u003ctable border=\"0\" cellpadding=\"0\" cellspacing=\"0\" width=\"512\" style=\"border-collapse: collapse; width: 512px;\"\u003e\n\u003ccolgroup\u003e \u003ccol width=\"172\" style=\"width: 172px;\"\u003e \u003ccol width=\"340\" style=\"width: 340px;\"\u003e \u003c\/colgroup\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eOptional\u003c\/td\u003e\n\u003ctd\u003eQSFP56\/QSFP28\/QSFP+ optical transceivers; copper direct-attach cables\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e[\/accesories]\u003c\/p\u003e\n\u003ch2\u003eHigh-Density 100GbE Server Networking with Broadcom Performance\u003c\/h2\u003e\n\u003cp\u003eThe Broadcom BCM957508-P2100G is a dual-port 100GbE PCI Express 4.0 x16 network interface card built for modern data center servers, virtualization stacks, and high-throughput storage fabrics. Based on the Broadcom BCM57508 200GbE MAC controller with an integrated dual-channel 100GbE SFI transceiver, it delivers reliable 100GbE connectivity while supporting advanced virtualization and tunneling acceleration.\u003c\/p\u003e\n\u003cp\u003eDesigned for QSFP56 environments, this NIC supports QSFP56, QSFP28, and QSFP+ optical modules as well as copper direct-attach cables, making it a flexible choice for upgrades, mixed-speed deployments, and scalable server builds.\u003c\/p\u003e\n\u003ch2\u003eKey Benefits \u0026amp; Features\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDual-port 100GbE connectivity:\u003c\/strong\u003e Built for high-throughput server uplinks using two QSFP56 ports for data center and cloud workloads.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBroadSAFE security technology:\u003c\/strong\u003e Designed as an industry-focused secure PCIe adapter solution leveraging Broadcom BroadSAFE technology.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSR-IOV virtualization at scale:\u003c\/strong\u003e Supports SR-IOV with up to 1K virtual functions (VFs to increase VM density and reduce CPU overhead.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTruFlow flow processing engine:\u003c\/strong\u003e Helps accelerate vSwitch and flow processing to improve efficiency in virtualized environments.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAdvanced tunnel and offload support:\u003c\/strong\u003e Supports VXLAN, NVGRE, Geneve, and GRE encapsulation\/decapsulation with tunnel-aware stateless offloads.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eIdeal Use Cases\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e100GbE server uplinks in enterprise and cloud data centers\u003c\/li\u003e\n\u003cli\u003eVirtualization hosts requiring SR-IOV and vSwitch acceleration\u003c\/li\u003e\n\u003cli\u003eHigh-performance computing and low-latency east-west traffic\u003c\/li\u003e\n\u003cli\u003eRoCE-enabled environments for RDMA-based workloads\u003c\/li\u003e\n\u003cli\u003eStorage and network fabrics using QSFP56 DAC or optical connectivity\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSKU:\u003c\/strong\u003e BCM957508-P2100G\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePorts:\u003c\/strong\u003e Dual-port QSFP56\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNetwork Speed:\u003c\/strong\u003e 2 x 100GbE (supports 50G PAM-4, 25G NRZ, 10G NRZ signaling\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHost Interface:\u003c\/strong\u003e PCI Express 4.0 x16\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eController:\u003c\/strong\u003e Broadcom BCM57508 200GbE MAC with integrated dual-channel 100GbE SFI transceiver\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSupported Media:\u003c\/strong\u003e QSFP56\/QSFP28\/QSFP+ optical modules and copper direct-attach cables\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVirtualization:\u003c\/strong\u003e SR-IOV up to 1K VFs, vSwitch acceleration, multiqueue, VMQ\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRDMA:\u003c\/strong\u003e RDMA over Converged Ethernet (RoCE\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eJumbo Frames:\u003c\/strong\u003e Up to 9 KB\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Consumption:\u003c\/strong\u003e 16.0W typical (passive DAC, up to 22.0W max (optical transceiver\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e 0 to 55 Celsius\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eForm Factor:\u003c\/strong\u003e PCIe add-in card, low-profile half-length (standard and low-profile brackets included\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eUpgrade to 100GbE Without Compromise\u003c\/h2\u003e\n\u003cp\u003eDeploy the Broadcom BCM957508-P2100G for scalable 100GbE performance, secure virtualization, and modern offload acceleration. \u003cstrong\u003eOrder today\u003c\/strong\u003e.\u003c\/p\u003e","brand":"Broadcom","offers":[{"title":"Default Title","offer_id":48012802851033,"sku":"BCM957508-P2100G-NEW","price":551.05,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0016\/5327\/6707\/files\/BCM957508-P2100G_3_1ce8632a-6a0a-4821-b458-2c720b349d3b.webp?v=1771845835","url":"https:\/\/www.aloinfousa.com\/es\/products\/broadcom-bcm957508-p2100g-dual-port-100gbe-network-interface-card-kwnno","provider":"aloinfousa.com","version":"1.0","type":"link"}