{"product_id":"juniper-ex2300-24t-vc-switch-bpfn1","title":"Juniper EX2300-24T-VC Switch","description":"\u003cdiv class=\"short-hide\"\u003e[shortdesc]\n\u003cul\u003e\n\u003cli\u003eSwitch\u003c\/li\u003e\n\u003cli\u003eL3\u003c\/li\u003e\n\u003cli\u003eManaged\u003c\/li\u003e\n\u003cli\u003e24 x 10\/100\/1000 + 4 x Gigabit SFP \/ 10 Gigabit SFP+\u003c\/li\u003e\n\u003cli\u003eDesktop\u003c\/li\u003e\n\u003cli\u003eRack-mountable\u003c\/li\u003e\n\u003cli\u003ewith Virtual Chassis License\u003c\/li\u003e\n\u003c\/ul\u003e\n[\/shortdesc]\u003c\/div\u003e\n\u003cp\u003e[properties]\u003c\/p\u003e\n\u003ctable width=\"516\" data-mce-fragment=\"1\"\u003e\n\u003ctbody data-mce-fragment=\"1\"\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd width=\"206\" data-mce-fragment=\"1\"\u003eProperties\u003c\/td\u003e\n\u003ctd width=\"310\" data-mce-fragment=\"1\"\u003eJuniper EX2300-24T-VC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd width=\"206\" data-mce-fragment=\"1\"\u003eDescription\u003c\/td\u003e\n\u003ctd width=\"310\" data-mce-fragment=\"1\"\u003eEX2300 24-port non-PoE+ w\/ Virtual Chassis License\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd width=\"206\" data-mce-fragment=\"1\"\u003eProduct Family\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eEX2300 Series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd width=\"206\" data-mce-fragment=\"1\"\u003eProduct Type\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eEthernet Switch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd width=\"206\" data-mce-fragment=\"1\"\u003eGbE Port Density\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e28 (24 host ports + 4-port SFP\/SFP+ uplinks)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd width=\"206\" data-mce-fragment=\"1\"\u003eDimensions (HxWxD) Inches\u003c\/td\u003e\n\u003ctd width=\"310\" data-mce-fragment=\"1\"\u003eWidth:\u003cbr data-mce-fragment=\"1\"\u003e- 17.4 in (44.19 cm) for desktop installations\u003cbr data-mce-fragment=\"1\"\u003e- 17.5 in (44.6 cm) with rack-mount brackets\u003cbr data-mce-fragment=\"1\"\u003eHeight: 1.75 in (4.45 cm) for 1U installations\u003cbr data-mce-fragment=\"1\"\u003eDepth: 10.2 in (25.9 cm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd width=\"206\" data-mce-fragment=\"1\"\u003eWeight\u003c\/td\u003e\n\u003ctd width=\"310\" data-mce-fragment=\"1\"\u003e7.25 lb (3.29 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd width=\"206\" data-mce-fragment=\"1\"\u003eCooling\u003c\/td\u003e\n\u003ctd width=\"310\" data-mce-fragment=\"1\"\u003eAirflow: 25cfm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd width=\"206\" data-mce-fragment=\"1\"\u003eBackplane\u003c\/td\u003e\n\u003ctd width=\"310\" data-mce-fragment=\"1\"\u003e80 Gbps Virtual Chassis interconnect to link up to four switches as a single logical device\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd width=\"516\" colspan=\"2\" data-mce-fragment=\"1\"\u003ePower Options\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd width=\"206\" data-mce-fragment=\"1\"\u003eMax. System Power Consumption (Input Power without PoE)\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eTotal PoE Power Budget\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e55 W AC\u003c\/td\u003e\n\u003ctd width=\"310\" data-mce-fragment=\"1\"\u003e0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd width=\"206\" data-mce-fragment=\"1\"\u003eAcoustic Noise in DB\u003c\/td\u003e\n\u003ctd width=\"310\" data-mce-fragment=\"1\"\u003e34.2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd width=\"206\" data-mce-fragment=\"1\"\u003e*Virtual Chassis technology enables up to four interconnected EX2300 switches to\u003cbr data-mce-fragment=\"1\"\u003eform a single logical device\u003c\/td\u003e\n\u003ctd width=\"310\" data-mce-fragment=\"1\"\u003e*Uplink ports can be configured as Virtual Chassis interfaces and connected via\u003cbr data-mce-fragment=\"1\"\u003estandard 10GbE optics interfaces.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd width=\"206\" data-mce-fragment=\"1\"\u003eVC Description\u003c\/td\u003e\n\u003ctd width=\"310\" data-mce-fragment=\"1\"\u003eThe EX2300 supports Junipers unique Virtual Chassis technology, enabling up to four interconnected EX2300 switches to be managed as a single logical device, delivering a scalable, pay-as-you grow solution for expanding network environments.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e[\/properties][specifications]\u003c\/p\u003e\n\u003ctable width=\"774\" data-mce-fragment=\"1\"\u003e\n\u003ctbody data-mce-fragment=\"1\"\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd width=\"395\" data-mce-fragment=\"1\"\u003eSpecifications\u003c\/td\u003e\n\u003ctd width=\"379\" data-mce-fragment=\"1\"\u003eEX2300-24T-VC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd width=\"395\" data-mce-fragment=\"1\"\u003eDRAM\u003c\/td\u003e\n\u003ctd width=\"379\" data-mce-fragment=\"1\"\u003e2 GB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd width=\"395\" data-mce-fragment=\"1\"\u003eFlash Memory\u003c\/td\u003e\n\u003ctd width=\"379\" data-mce-fragment=\"1\"\u003e2 GB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd width=\"395\" data-mce-fragment=\"1\"\u003eCPU\u003c\/td\u003e\n\u003ctd width=\"379\" data-mce-fragment=\"1\"\u003e1.25GHz ARM CPU\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd width=\"395\" data-mce-fragment=\"1\"\u003eSupported Optics\u003c\/td\u003e\n\u003ctd width=\"379\" data-mce-fragment=\"1\"\u003e10\/100\/1000BASE-T connector type RJ-45\u003cbr data-mce-fragment=\"1\"\u003eGbE SFP optic\/connector type: RJ-45, or LC SFP fiber\u003cbr data-mce-fragment=\"1\"\u003esupporting 1000BASE-T SFP, SX (multimode), LX (singlemode), or LH (single-mode)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd width=\"395\" data-mce-fragment=\"1\"\u003ePhysical Layer\u003c\/td\u003e\n\u003ctd width=\"379\" data-mce-fragment=\"1\"\u003ePhysical port redundancy: Redundant trunk group (RTG)\u003cbr data-mce-fragment=\"1\"\u003eCable diagnostics for detecting cable breaks and shorts\u003cbr data-mce-fragment=\"1\"\u003eAuto MDI\/MDIX (medium-dependent interface\/\u003cbr data-mce-fragment=\"1\"\u003emedium-dependent interface crossover) support\u003cbr data-mce-fragment=\"1\"\u003ePort speed downshift\/setting maximum advertised speed on 10\/100\/1000BASE-T ports\u003cbr data-mce-fragment=\"1\"\u003eDigital optical monitoring for optical ports\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd width=\"395\" data-mce-fragment=\"1\"\u003ePacket-Switching Capacities\u003c\/td\u003e\n\u003ctd width=\"379\" data-mce-fragment=\"1\"\u003e64 Gbps (unidirectional)\/128 Gbps (bidirectional)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd width=\"774\" colspan=\"2\" data-mce-fragment=\"1\"\u003eSoftware Specifications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd width=\"395\" data-mce-fragment=\"1\"\u003eLayer 2\/Layer 3 Throughput (Mpps) (Maximum with 64 Byte Packets)\u003c\/td\u003e\n\u003ctd width=\"379\" data-mce-fragment=\"1\"\u003e95 Mpps (wire speed)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd width=\"395\" data-mce-fragment=\"1\"\u003eLayer 2 Features\u003c\/td\u003e\n\u003ctd width=\"379\" data-mce-fragment=\"1\"\u003eMaximum MAC addresses in hardware: 16,000\u003cbr data-mce-fragment=\"1\"\u003eJumbo frames: 9216 bytes\u003cbr data-mce-fragment=\"1\"\u003eNumber of VLANs supported: 4093 (2044 active VLAN)\u003cbr data-mce-fragment=\"1\"\u003eRange of possible VLAN IDs: 1-4094\u003cbr data-mce-fragment=\"1\"\u003ePort-based VLAN\u003cbr data-mce-fragment=\"1\"\u003eMAC-based VLAN\u003cbr data-mce-fragment=\"1\"\u003eVoice VLAN\u003cbr data-mce-fragment=\"1\"\u003eLayer 2 Protocol Tunneling (L2PT)\u003cbr data-mce-fragment=\"1\"\u003eIEEE 802.1ak: Multiple VLAN Registration Protocol (MVRP)\u003cbr data-mce-fragment=\"1\"\u003eCompatible with Per-VLAN Spanning Tree Plus (PVST+)\u003cbr data-mce-fragment=\"1\"\u003eRVI (Routed VLAN Interface)\u003cbr data-mce-fragment=\"1\"\u003eIEEE 802.1AB: Link Layer Discovery Protocol (LLDP)\u003cbr data-mce-fragment=\"1\"\u003eLLDP-MED with VoIP integration\u003cbr data-mce-fragment=\"1\"\u003eIEEE 802.1ad Q-in-Q tunneling\u003cbr data-mce-fragment=\"1\"\u003eIEEE 802.1br: Bridge Port Extension\u003cbr data-mce-fragment=\"1\"\u003eIEEE 802.1D: Spanning Tree Protocol\u003cbr data-mce-fragment=\"1\"\u003eIEEE 802.1p: CoS Prioritization\u003cbr data-mce-fragment=\"1\"\u003eIEEE 802.1Q: VLAN Tagging\u003cbr data-mce-fragment=\"1\"\u003eIEEE 802.1Q-in-Q: VLAN Stacking\u003cbr data-mce-fragment=\"1\"\u003eIEEE 802.1s: Multiple Spanning Tree Protocol (MSTP)\u003cbr data-mce-fragment=\"1\"\u003eNumber of MST instances supported: 64\u003cbr data-mce-fragment=\"1\"\u003eNumber of VSTP instances supported: 253\u003cbr data-mce-fragment=\"1\"\u003eIEEE 802.1w: Rapid Spanning Tree Protocol (RSTP)\u003cbr data-mce-fragment=\"1\"\u003eIEEE 802.1X: Port Access Control\u003cbr data-mce-fragment=\"1\"\u003eIEEE 802.3: 10BASE-T\u003cbr data-mce-fragment=\"1\"\u003eIEEE 802.3u: 100BASE-T\u003cbr data-mce-fragment=\"1\"\u003eIEEE 802.3ab: 1000BASE-T\u003cbr data-mce-fragment=\"1\"\u003eIEEE 802.3z: 1000BASE-X\u003cbr data-mce-fragment=\"1\"\u003eIEEE 802.3af: PoE\u003cbr data-mce-fragment=\"1\"\u003eIEEE 802.3at: PoE+\u003cbr data-mce-fragment=\"1\"\u003eIEEE 802.3ad: Link Aggregation Control Protocol (LACP)\u003cbr data-mce-fragment=\"1\"\u003eIEEE 802.3x: Pause Frames\/Flow Control\u003cbr data-mce-fragment=\"1\"\u003eIEEE 802.3az: Energy Efficient Ethernet\u003cbr data-mce-fragment=\"1\"\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd width=\"395\" data-mce-fragment=\"1\"\u003eLayer 3 Features: IPv4\u003c\/td\u003e\n\u003ctd width=\"379\" data-mce-fragment=\"1\"\u003eMaximum number of ARP entries: 1,500\u003cbr data-mce-fragment=\"1\"\u003eMaximum number of IPv4 unicast routes in hardware: 512\u003cbr data-mce-fragment=\"1\"\u003eprefixes; 4,096 host routes\u003cbr data-mce-fragment=\"1\"\u003eMaximum number of IPv4 multicast routes in hardware: 2,048\u003cbr data-mce-fragment=\"1\"\u003egroups; 2,048 multicast routes\u003cbr data-mce-fragment=\"1\"\u003eRouting Protocols: RIP v1\/v2, OSPF v1\/v2\u003cbr data-mce-fragment=\"1\"\u003eStatic routing\u003cbr data-mce-fragment=\"1\"\u003eRouting policy\u003cbr data-mce-fragment=\"1\"\u003eBidirectional Forwarding Detection (BFD) with slow timers (\u0026gt; 3\u003cbr data-mce-fragment=\"1\"\u003esec)\u003cbr data-mce-fragment=\"1\"\u003eIP-directed broadcast\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd width=\"395\" data-mce-fragment=\"1\"\u003eLayer 3 Features: IPv6\u003c\/td\u003e\n\u003ctd width=\"379\" data-mce-fragment=\"1\"\u003eMaximum number of Neighbor Discovery (ND) entries: 1,500\u003cbr data-mce-fragment=\"1\"\u003eMaximum number of IPv6 unicast routes in hardware: 512\u003cbr data-mce-fragment=\"1\"\u003eprefixes; 2,048 host routes\u003cbr data-mce-fragment=\"1\"\u003eMaximum number of IPv6 multicast routes in hardware: 1,024\u003cbr data-mce-fragment=\"1\"\u003egroups; 1,024 multicast routes\u003cbr data-mce-fragment=\"1\"\u003eNeighbor discovery, system logging, Telnet, SSH, SNMP,\u003cbr data-mce-fragment=\"1\"\u003eNetwork Time Protocol (NTP), Domain Name System (DNS)\u003cbr data-mce-fragment=\"1\"\u003eStatic routing\u003cbr data-mce-fragment=\"1\"\u003eRouting protocols: RIPng, OSPF v3, Multicast Listener\u003cbr data-mce-fragment=\"1\"\u003eDiscovery, Multicast Listener Discovery v2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd width=\"395\" data-mce-fragment=\"1\"\u003eAccess Control Lists (ACLs) (Junos OS Firewall Filters)\u003c\/td\u003e\n\u003ctd width=\"379\" data-mce-fragment=\"1\"\u003ePort-based ACL (PACL)256 ingress; 256 egress\u003cbr data-mce-fragment=\"1\"\u003eVLAN-based ACL (VACL) 256 ingress; 256 egress\u003cbr data-mce-fragment=\"1\"\u003eRouter-based ACL (RACL)256 ingress; 512 egress\u003cbr data-mce-fragment=\"1\"\u003eACL entries (ACE) in hardware per system: 2,000\u003cbr data-mce-fragment=\"1\"\u003eACL counter for denied packets\u003cbr data-mce-fragment=\"1\"\u003eACL counter for permitted packets\u003cbr data-mce-fragment=\"1\"\u003eAbility to add\/remove\/change ACL entries in the middle of the list\u003cbr data-mce-fragment=\"1\"\u003e(ACL editing)\u003cbr data-mce-fragment=\"1\"\u003eL2-L4 ACL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd width=\"395\" data-mce-fragment=\"1\"\u003eAccess Security\u003c\/td\u003e\n\u003ctd width=\"379\" data-mce-fragment=\"1\"\u003eMAC limiting\u003cbr data-mce-fragment=\"1\"\u003eAllowed MAC addressesconfigurable per port\u003cbr data-mce-fragment=\"1\"\u003eSticky MAC (persistent MAC address learning)\u003cbr data-mce-fragment=\"1\"\u003eDynamic ARP inspection (DAI)\u003cbr data-mce-fragment=\"1\"\u003eProxy ARP\u003cbr data-mce-fragment=\"1\"\u003eStatic ARP support\u003cbr data-mce-fragment=\"1\"\u003eDHCP snooping\u003cbr data-mce-fragment=\"1\"\u003e802.1X port-based\u003cbr data-mce-fragment=\"1\"\u003e802.1X multiple supplicants\u003cbr data-mce-fragment=\"1\"\u003e802.1X with VLAN assignment\u003cbr data-mce-fragment=\"1\"\u003e802.1X with authentication bypass access (based on host MAC\u003cbr data-mce-fragment=\"1\"\u003eaddress)\u003cbr data-mce-fragment=\"1\"\u003e802.1X with VoIP VLAN support\u003cbr data-mce-fragment=\"1\"\u003e802.1X dynamic ACL based on RADIUS attributes\u003cbr data-mce-fragment=\"1\"\u003e802.1X Supported EAP types: Message Digest 5 (MD5),\u003cbr data-mce-fragment=\"1\"\u003eTransport Layer Security (TLS), Tunneled Transport Layer\u003cbr data-mce-fragment=\"1\"\u003eSecurity (TTLS), Protected Extensible Authentication Protocol\u003cbr data-mce-fragment=\"1\"\u003e(PEAP)\u003cbr data-mce-fragment=\"1\"\u003eIPv6 RA Guard\u003cbr data-mce-fragment=\"1\"\u003eIPv6 Neighbor Discovery Inspection\u003cbr data-mce-fragment=\"1\"\u003eCaptive Portal\u003cbr data-mce-fragment=\"1\"\u003eStatic MAC authentication\u003cbr data-mce-fragment=\"1\"\u003eMAC-RADIUS\u003cbr data-mce-fragment=\"1\"\u003eControl plane DoS protection\u003cbr data-mce-fragment=\"1\"\u003eFallback authentication\u003cbr data-mce-fragment=\"1\"\u003eTrusted Network Connect (TNC) certified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd width=\"395\" data-mce-fragment=\"1\"\u003eHigh Availability\u003c\/td\u003e\n\u003ctd width=\"379\" data-mce-fragment=\"1\"\u003eLink aggregation\u003cbr data-mce-fragment=\"1\"\u003e802.3ad (LACP) support:\u003cbr data-mce-fragment=\"1\"\u003e- Number of LAGs supported: 128\u003cbr data-mce-fragment=\"1\"\u003e- Maximum number of ports per LAG: 8\u003cbr data-mce-fragment=\"1\"\u003eTagged ports support in LAG\u003cbr data-mce-fragment=\"1\"\u003eUplink Failure Detection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd width=\"395\" data-mce-fragment=\"1\"\u003eQuality of Service (QoS)\u003c\/td\u003e\n\u003ctd width=\"379\" data-mce-fragment=\"1\"\u003eLayer 2 QoS\u003cbr data-mce-fragment=\"1\"\u003eLayer 3 QoS\u003cbr data-mce-fragment=\"1\"\u003eIngress policing: one-rate two-color; two-rate three-color\u003cbr data-mce-fragment=\"1\"\u003emarkers\u003cbr data-mce-fragment=\"1\"\u003eHardware queues per port: 8\u003cbr data-mce-fragment=\"1\"\u003eScheduling methods (egress): Strict Priority (SP), shapeddeficit\u003cbr data-mce-fragment=\"1\"\u003eweighted round-robin (SDWRR)\u003cbr data-mce-fragment=\"1\"\u003e802.1p, DSCP \/IP precedence trust and marking\u003cbr data-mce-fragment=\"1\"\u003eL2-L4 classification criteria: Interface, MAC address, EtherType,\u003cbr data-mce-fragment=\"1\"\u003e802.1p, VLAN, IP address, DSCP\/IP precedence, TCP\/UDP\u003cbr data-mce-fragment=\"1\"\u003eport numbers\u003cbr data-mce-fragment=\"1\"\u003eCongestion avoidance capabilities: Tail drop and WRED\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd width=\"395\" data-mce-fragment=\"1\"\u003eMulticast\u003c\/td\u003e\n\u003ctd width=\"379\" data-mce-fragment=\"1\"\u003eIGMP snooping entries: 2,000\u003cbr data-mce-fragment=\"1\"\u003eIGMP: v1, v2, v3\u003cbr data-mce-fragment=\"1\"\u003eIGMP snooping\u003cbr data-mce-fragment=\"1\"\u003ePIM-SM, PIM-SSM, PIM-DM\u003cbr data-mce-fragment=\"1\"\u003eMLD snooping\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd width=\"395\" data-mce-fragment=\"1\"\u003eDevice Management and Operations\u003c\/td\u003e\n\u003ctd width=\"379\" data-mce-fragment=\"1\"\u003eJunos OS CLI\u003cbr data-mce-fragment=\"1\"\u003eJunos Web interface (J-Web)\u003cbr data-mce-fragment=\"1\"\u003eOut-of-band management: Serial, 10\/100BASE-T Ethernet\u003cbr data-mce-fragment=\"1\"\u003eASCII configuration\u003cbr data-mce-fragment=\"1\"\u003eRescue configuration\u003cbr data-mce-fragment=\"1\"\u003eConfiguration rollback\u003cbr data-mce-fragment=\"1\"\u003eImage rollback\u003cbr data-mce-fragment=\"1\"\u003eSimple Network Management Protocol (SNMP): v1, v2c, v3\u003cbr data-mce-fragment=\"1\"\u003eRemote monitoring (RMON) (RFC 2819) Groups 1, 2, 3, 9\u003cbr data-mce-fragment=\"1\"\u003eNetwork Time Protocol (NTP)\u003cbr data-mce-fragment=\"1\"\u003eDHCP server\u003cbr data-mce-fragment=\"1\"\u003eDHCP client and DHCP proxy\u003cbr data-mce-fragment=\"1\"\u003eDHCP relay and helper\u003cbr data-mce-fragment=\"1\"\u003eRADIUS authentication\u003cbr data-mce-fragment=\"1\"\u003eTACACS+ authentication\u003cbr data-mce-fragment=\"1\"\u003eSSHv2\u003cbr data-mce-fragment=\"1\"\u003eSecure copy\u003cbr data-mce-fragment=\"1\"\u003eHTTP\/HTTPs\u003cbr data-mce-fragment=\"1\"\u003eDNS resolver\u003cbr data-mce-fragment=\"1\"\u003eSystem log logging\u003cbr data-mce-fragment=\"1\"\u003eTemperature sensor\u003cbr data-mce-fragment=\"1\"\u003eConfiguration backup via FTP\/secure copy\u003cbr data-mce-fragment=\"1\"\u003eInterface range\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eOperating temperature\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e32° to 113° F (0° to 45° C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eStorage temperature\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e-40° to 158° F (-40° to 70° C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eOperating altitude\u003c\/td\u003e\n\u003ctd width=\"379\" data-mce-fragment=\"1\"\u003eup to 13,000 ft (3962 m) at 40° C according to GR-63\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eNon-operating altitude\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eup to 15,000 ft (4572 m)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eRelative humidity operating\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e10% to 85% (noncondensing)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eRelative humidity non-operating\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e0% to 95% (noncondensing)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd width=\"395\" data-mce-fragment=\"1\"\u003eSafety Certifications\u003c\/td\u003e\n\u003ctd width=\"379\" data-mce-fragment=\"1\"\u003eUL-UL60950-1 (Second Edition)\u003cbr data-mce-fragment=\"1\"\u003eC-UL to CAN\/CSA 22.2 No.60950-1 (Second Edition)\u003cbr data-mce-fragment=\"1\"\u003eTUV\/GS to EN 60950-1 (Second Edition)\u003cbr data-mce-fragment=\"1\"\u003eCB-IEC60950-1 (Second Edition with all country deviations)\u003cbr data-mce-fragment=\"1\"\u003eEN 60825-1 (Second Edition)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd width=\"395\" data-mce-fragment=\"1\"\u003eElectromagnetic Compatibility Certifications\u003c\/td\u003e\n\u003ctd width=\"379\" data-mce-fragment=\"1\"\u003eFCC 47CFR Part 15 Class A\u003cbr data-mce-fragment=\"1\"\u003eEN 55022 Class A\u003cbr data-mce-fragment=\"1\"\u003eICES-003 Class A\u003cbr data-mce-fragment=\"1\"\u003eVCCI Class A\u003cbr data-mce-fragment=\"1\"\u003eAS\/NZS CISPR 22 Class A\u003cbr data-mce-fragment=\"1\"\u003eCISPR 22 Class A\u003cbr data-mce-fragment=\"1\"\u003eEN 55024\u003cbr data-mce-fragment=\"1\"\u003eEN 300386\u003cbr data-mce-fragment=\"1\"\u003eCE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd width=\"395\" data-mce-fragment=\"1\"\u003eTelecom Quality Management\u003c\/td\u003e\n\u003ctd width=\"379\" data-mce-fragment=\"1\"\u003eTL9000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd width=\"395\" data-mce-fragment=\"1\"\u003eEnvironmental\u003c\/td\u003e\n\u003ctd width=\"379\" data-mce-fragment=\"1\"\u003eReduction of Hazardous Substances (ROHS) 6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd width=\"395\" data-mce-fragment=\"1\"\u003eTelco\u003c\/td\u003e\n\u003ctd width=\"379\" data-mce-fragment=\"1\"\u003eCLEI code\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e[\/specifications][accesories]\u003c\/p\u003e\n\u003ctable width=\"434\" data-mce-fragment=\"1\"\u003e\n\u003ctbody data-mce-fragment=\"1\"\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd colspan=\"2\" width=\"434\" data-mce-fragment=\"1\"\u003eAccessories and License Upgrade PIDs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eEX-RMK\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eRack-mount kit for EX2300\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eEX-4PST-RMK\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eAdjustable 4-post rack-mount kit for EX2300\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eEX-WMK\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eWall-mount kit for EX2300\u003cbr data-mce-fragment=\"1\"\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd colspan=\"2\" data-mce-fragment=\"1\"\u003eSubscription Licenses\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eS-EX-A-C2-3\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eSoftware, EX Series Advanced license, Class 2 (24 ports), includes\u003cbr data-mce-fragment=\"1\"\u003eWired Assurance subscription for EX Series 24-port switches, 3\u003cbr data-mce-fragment=\"1\"\u003eyear\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eS-EX-A-C2-5\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eSoftware, EX Series Advanced license, Class 2 (24 ports), includes\u003cbr data-mce-fragment=\"1\"\u003eWired Assurance subscription for EX Series 24-port switches, 5\u003cbr data-mce-fragment=\"1\"\u003eyear\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eS-EX-A-C2-3-COR\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eSoftware, EX Series Advanced license, Class 2 (24 ports), includes Wired Assurance subscription for EX Series 24-port switches with SVC CORE support, 3 year\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eS-EX-A-C2-5-COR\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eSoftware, EX Series Advanced license, Class 2 (24 ports), includes Wired Assurance subscription for EX Series 24-port switches with SVC CORE support, 5 year\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd colspan=\"2\" data-mce-fragment=\"1\"\u003ePerpetual Licenses\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eEX2300-VC\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eEX2300 Virtual Chassis License for EX2300 24- 48-port switches\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eS-EX-A-C2-P\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eSoftware, EX Series Advanced license, Class 2 Perpetual license for 24 port switches\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eEX-24-EFL\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eEnhanced Feature License for EX2300 24-port switches\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd colspan=\"2\" data-mce-fragment=\"1\"\u003ePluggable Optics\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eEX-SFP-1GE-T\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eSFP 10\/100\/1000BASE-T copper; RJ-45 connector; 100m reach on UTP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eEX-SFP-1GE-SX\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eSFP 1000BASE-SX; LC connector; 850 nm; 550m reach on multimode fiber\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eEX-SFP-1GE-SX-ET\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eSFP 1000BASE-SX; LC connector; 850 nm; 550m reach on multimode fiber, extended temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eEX-SFP-1GE-LX\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eSFP 1000BASE-LX; LC connector; 1310 nm; 10 km reach on single-mode fiber\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eEX-SFP-1GE-LH\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eSFP 1000BASE-LH; LC connector; 1550 nm; 70 km reach on single-mode fiber\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eEX-SFP-1GE-LX40K\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eSFP 1000BASE-LX; LC connector; 1310 nm; 40 km reach on single-mode fiber\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eEX-SFP-GE10KT13R14\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eSFP 1000BASE-BX; TX 1310 nm\/RX 1490 nm for 10 km transmission on single-strand, single-mode fiber\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eEX-SFP-GE10KT13R15\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eSFP 1000BASE-BX; TX 1310 nm\/RX 1550 nm for 10 km transmission on single-strand, single-mode fiber\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eEX-SFP-GE10KT14R13\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eSFP 1000BASE-BX; TX 1490 nm\/RX 1310 nm for 10 km transmission on single-strand, single-mode fiber\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eEX-SFP-GE10KT15R13\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eSFP 1000BASE-BX; TX 1550 nm\/RX 1310 nm for 10 km transmission on single-strand, single-mode fiber\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eEX-SFP-GE40KT13R15\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eSFP 1000BASE-BX; TX 1310 nm\/RX 1550 nm for 40 km transmission on single-strand, single-mode fiber\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eEX-SFPGE80KCW1470\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eSFP Gigabit Ethernet CWDM, LC connector; 1470 nm, 80 km reach on single-mode fiber\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eEX-SFPGE80KCW1490\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eSFP Gigabit Ethernet CWDM, LC connector; 1490 nm, 80 km reach on single-mode fiber\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eEX-SFPGE80KCW1510\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eSFP Gigabit Ethernet CWDM, LC connector; 1510 nm, 80 km reach on single-mode fiber\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eEX-SFPGE80KCW1530\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eSFP Gigabit Ethernet CWDM, LC connector; 1530 nm, 80 km reach on single-mode fiber\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eEX-SFPGE80KCW1550\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eSFP Gigabit Ethernet CWDM, LC connector; 1550 nm, 80 km reach on single-mode fiber\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eEX-SFPGE80KCW1570\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eSFP Gigabit Ethernet CWDM, LC connector; 1570 nm, 80 km reach on single-mode fiber\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eEX-SFPGE80KCW1590\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eSFP Gigabit Ethernet CWDM, LC connector; 1590 nm, 80 km reach on single-mode fiber\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eEX-SFPGE80KCW1610\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eSFP Gigabit Ethernet CWDM, LC connector; 1610 nm, 80 km reach on single-mode fiber\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eEX-SFP-10GE-USR\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eSFP+ 10 Gigabit Ethernet Ultra Short Reach Optics, 850 nm for 10m on OM1, 20m on OM2, 100m on OM3 multimode fiber\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eEX-SFP-10GE-SR\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eSFP+ 10GBASE-SR; LC connector; 850 nm; 300m reach on 50 microns multimode fiber; 33m on 62.5 microns multimode fiber\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eEX-SFP-10GE-LR\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eSFP+ 10GBASE-LR; LC connector; 1310 nm; 10 km reach on single-mode fiber\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eEX-SFP-10GE-ER\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eSFP+ 10GBASE-ER 10 Gigabit Ethernet Optics, 1550 nm for 40 km transmission on single-mode fiber\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eEX-SFP-10GE-ZR\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eSFP+ 10GBASE-ZR; LC connector; 1550nm; 80 km reach on single-mode fiber\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eEX-SFP-10GE-DAC1M\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eSFP+ 10 Gigabit Ethernet Direct Attach Copper (twinax copper cable) 1-meter length\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eEX-SFP-10GE-DAC3M\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eSFP+ 10 Gigabit Ethernet Direct Attach Copper (twinax copper cable) 3-meter length\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eEX-SFP-10GE-DAC5M\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eSFP+ 10 Gigabit Ethernet Direct Attach Copper (twinax copper cable) 5-meter length\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e[\/accesories]\u003c\/p\u003e\n\u003ch2\u003eJuniper EX2300 24T VC Switch\u003c\/h2\u003e\n\u003cp\u003eThe Juniper EX2300 VC switch offers advanced virtualization features, such as Virtual Chassis technology, allowing multiple switches to be managed as a single logical device. This simplifies network management, reduces complexity, and improves scalability for growing networks.\u003c\/p\u003e\n\u003ch3\u003eSome key specs are:\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e24-port non-PoE+\u003c\/li\u003e\n\u003cli\u003eL2 and L3 capabilities\u003c\/li\u003e\n\u003cli\u003eFixed-configuration\u003c\/li\u003e\n\u003cli\u003eVirtual Chassis License\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003ePlease check the specifications tab above for the EX2300 24T VC datasheet and compatible accessories.\u003c\/p\u003e","brand":"Juniper","offers":[{"title":"Default Title","offer_id":48013264978137,"sku":"EX2300-24T-VC-NEW","price":1479.17,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0016\/5327\/6707\/files\/EX2300-24T-VC_1_7a77d4b5-7197-4cca-bd73-7104a63b7f65.webp?v=1771852941","url":"https:\/\/www.aloinfousa.com\/es\/products\/juniper-ex2300-24t-vc-switch-bpfn1","provider":"aloinfousa.com","version":"1.0","type":"link"}