{"product_id":"juniper-ex2300-c-12t-vc-switch-with-virtual-chassis-license-3s9d4","title":"Juniper EX2300-C-12T-VC Switch with Virtual Chassis License","description":"\u003cdiv class=\"short-hide\"\u003e[shortdesc]\n\u003cul\u003e\n\u003cli\u003e\n\u003c\/li\u003e\n\u003cli\u003eSwitch\u003c\/li\u003e\n\u003cli\u003eL3\u003c\/li\u003e\n\u003cli\u003emanaged\u003c\/li\u003e\n\u003cli\u003e12 x 10\/100\/1000 + 2 x Gigabit SFP \/ 10 Gigabit SFP+\u003c\/li\u003e\n\u003cli\u003erack-mountable\u003c\/li\u003e\n\u003cli\u003ewith‚ Virtual Chassis License\u003c\/li\u003e\n\u003c\/ul\u003e\n[\/shortdesc]\u003c\/div\u003e\n\u003cp\u003e[properties]\u003c\/p\u003e\n\u003ctable width=\"563\" data-mce-fragment=\"1\"\u003e\n\u003ctbody data-mce-fragment=\"1\"\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd width=\"253\" data-mce-fragment=\"1\"\u003eProperties\u003c\/td\u003e\n\u003ctd width=\"310\" data-mce-fragment=\"1\"\u003eJuniper EX2300-C-12T-VC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd width=\"253\" data-mce-fragment=\"1\"\u003eDescription\u003c\/td\u003e\n\u003ctd width=\"310\" data-mce-fragment=\"1\"\u003eEX2300 Compact Fanless 12-port 10\/100\/1000BASE-T, 2 x 1\/10GbE SFP\/SFP+ with Virtual Chassis License (optics sold separately)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd width=\"253\" data-mce-fragment=\"1\"\u003eProduct Family\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eEX2300-C Series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd width=\"253\" data-mce-fragment=\"1\"\u003eProduct Type\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eEthernet Switch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd width=\"253\" data-mce-fragment=\"1\"\u003eGbE Port Density\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e14 (12 access ports + 2 uplink ports)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd width=\"253\" data-mce-fragment=\"1\"\u003eDimensions (HxWxD) Inches\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e10.98 x 1.72 x 9.4 in (27.9 x 4.4 x 23.9 cm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd width=\"253\" data-mce-fragment=\"1\"\u003eWeight\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e5.45 lb (2.48 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd width=\"253\" data-mce-fragment=\"1\"\u003eCooling\u003c\/td\u003e\n\u003ctd width=\"310\" data-mce-fragment=\"1\"\u003eFanless Operation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd width=\"253\" data-mce-fragment=\"1\"\u003eBackplane\u003c\/td\u003e\n\u003ctd width=\"310\" data-mce-fragment=\"1\"\u003e40 Gbps Virtual Chassis interconnect to link up to four switches as a single logical device\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd width=\"253\" data-mce-fragment=\"1\"\u003eProduct Options\u003c\/td\u003e\n\u003ctd width=\"310\" data-mce-fragment=\"1\"\u003eAccess Port Configuration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd width=\"253\" data-mce-fragment=\"1\"\u003eAccess Port Configuration\u003c\/td\u003e\n\u003ctd width=\"310\" data-mce-fragment=\"1\"\u003e12-port 10\/100\/1000BASE-T\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd width=\"253\" data-mce-fragment=\"1\"\u003eUplink Ports\u003c\/td\u003e\n\u003ctd width=\"310\" data-mce-fragment=\"1\"\u003eTwo SFP\/SFP+ ports\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd width=\"253\" data-mce-fragment=\"1\"\u003ePoE+ Capable Ports\u003c\/td\u003e\n\u003ctd width=\"310\" data-mce-fragment=\"1\"\u003e0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd width=\"253\" data-mce-fragment=\"1\"\u003eHeight\u003c\/td\u003e\n\u003ctd width=\"310\" data-mce-fragment=\"1\"\u003e1 RU\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd width=\"253\" data-mce-fragment=\"1\"\u003ePoE+ Budget\u003c\/td\u003e\n\u003ctd width=\"310\" data-mce-fragment=\"1\"\u003eN\/A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd width=\"253\" data-mce-fragment=\"1\"\u003ePower Supply Rating\u003c\/td\u003e\n\u003ctd width=\"310\" data-mce-fragment=\"1\"\u003e40 W AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd width=\"563\" colspan=\"2\" data-mce-fragment=\"1\"\u003ePower Options\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd width=\"253\" data-mce-fragment=\"1\"\u003eMax. System Power Consumption (Input Power without PoE)\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eTotal PoE Power Budget\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e20 W AC\u003c\/td\u003e\n\u003ctd width=\"310\" data-mce-fragment=\"1\"\u003e0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd width=\"253\" data-mce-fragment=\"1\"\u003eAcoustic Noise in DB\u003c\/td\u003e\n\u003ctd width=\"310\" data-mce-fragment=\"1\"\u003e0 DB (Fanless)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd width=\"253\" data-mce-fragment=\"1\"\u003e*EX2300-C Virtual Chassis configurations operate as highly resilient unified systems, providing simplified management using a single IP address, single telnet\/SSH session, single command-line interface (CLI), automatic version checking, and automatic configuration. The EX2300-C switches are also capable of local switching, so packets coming into a port destined for another port on the same switch do not have to traverse the Virtual Chassis, increasing forwarding capacities.\u003c\/td\u003e\n\u003ctd width=\"310\" data-mce-fragment=\"1\"\u003e*While EX2300-C switches can be interconnected over either of the two front panel 10GbE uplink ports, these ports can also be configured as 1GbE uplinks to aggregation devices by disabling the Virtual Chassis technology.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eVC Description\u003c\/td\u003e\n\u003ctd width=\"310\" data-mce-fragment=\"1\"\u003eThe EX2300-C supports Junipers unique Virtual Chassis technology, enabling up to four interconnected EX2300-C switches to be managed as a single logical device and delivering a scalable, pay-as-you-grow solution for expanding network environments. The EX2300-C can also be connected to an existing Virtual Chassis configuration composed of EX2300 switches.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e[\/properties]\u003cbr\u003e\u003cbr\u003e[specifications]\u003c\/p\u003e\n\u003ctable width=\"774\" data-mce-fragment=\"1\"\u003e\n\u003ctbody data-mce-fragment=\"1\"\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd width=\"395\" data-mce-fragment=\"1\"\u003eSpecifications\u003c\/td\u003e\n\u003ctd width=\"379\" data-mce-fragment=\"1\"\u003eEX2300-C-12T-VC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd width=\"395\" data-mce-fragment=\"1\"\u003eDRAM\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e2 GB with ECC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd width=\"395\" data-mce-fragment=\"1\"\u003eFlash Memory\u003c\/td\u003e\n\u003ctd width=\"379\" data-mce-fragment=\"1\"\u003e2 GB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd width=\"395\" data-mce-fragment=\"1\"\u003eCPU\u003c\/td\u003e\n\u003ctd width=\"379\" data-mce-fragment=\"1\"\u003e1.25GHz ARM CPU\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd width=\"395\" data-mce-fragment=\"1\"\u003ePhysical Layer\u003c\/td\u003e\n\u003ctd width=\"379\" data-mce-fragment=\"1\"\u003ePhysical port redundancy: Redundant trunk group (RTG) \u003cbr data-mce-fragment=\"1\"\u003eCable diagnostics for detecting cable breaks and shorts \u003cbr data-mce-fragment=\"1\"\u003eAuto medium-dependent interface\/medium-dependent interface crossover (MDI\/MDIX) support \u003cbr data-mce-fragment=\"1\"\u003ePort speed downshift\/setting maximum advertised speed on 10\/100\/1000BASE-T ports \u003cbr data-mce-fragment=\"1\"\u003eDigital optical monitoring for optical ports\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd width=\"395\" data-mce-fragment=\"1\"\u003ePacket-Switching Capacities\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e32 Gbps (unidirectional)\/64 Gbps (bidirectional)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd width=\"774\" colspan=\"2\" data-mce-fragment=\"1\"\u003eSoftware Specifications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd width=\"395\" data-mce-fragment=\"1\"\u003eLayer 2\/Layer 3 Throughput (Mpps) (Maximum with 64 Byte Packets)\u003c\/td\u003e\n\u003ctd width=\"379\" data-mce-fragment=\"1\"\u003e47 Mpps (wire speed)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd width=\"395\" data-mce-fragment=\"1\"\u003eLayer 2 Features\u003c\/td\u003e\n\u003ctd width=\"379\" data-mce-fragment=\"1\"\u003eMaximum MAC addresses in hardware: 16,000 \u003cbr data-mce-fragment=\"1\"\u003eJumbo frames: 9216 bytes \u003cbr data-mce-fragment=\"1\"\u003eNumber of VLANs supported: 4093 (2044 active VLAN) \u003cbr data-mce-fragment=\"1\"\u003eRange of possible VLAN IDs: 1-4094 \u003cbr data-mce-fragment=\"1\"\u003ePort-based VLAN \u003cbr data-mce-fragment=\"1\"\u003eMAC-based VLAN \u003cbr data-mce-fragment=\"1\"\u003eVoice VLAN \u003cbr data-mce-fragment=\"1\"\u003eLayer 2 Protocol Tunneling (L2PT) \u003cbr data-mce-fragment=\"1\"\u003eIEEE 802.1ak: Multiple VLAN Registration Protocol (MVRP) \u003cbr data-mce-fragment=\"1\"\u003eCompatible with Per-VLAN Spanning Tree Plus (PVST+) \u003cbr data-mce-fragment=\"1\"\u003eRVI (Routed VLAN Interface) \u003cbr data-mce-fragment=\"1\"\u003eIEEE 802.1AB: Link Layer Discovery Protocol (LLDP) \u003cbr data-mce-fragment=\"1\"\u003eLLDP-MED with VoIP integration \u003cbr data-mce-fragment=\"1\"\u003eIEEE 802.1ad Q-in-Q tunneling \u003cbr data-mce-fragment=\"1\"\u003eIEEE 802.1br Bridge Port Extension \u003cbr data-mce-fragment=\"1\"\u003eIEEE 802.1D: Spanning Tree Protocol \u003cbr data-mce-fragment=\"1\"\u003eIEEE 802.1p: CoS Prioritization \u003cbr data-mce-fragment=\"1\"\u003eIEEE 802.1Q: VLAN Tagging\u003cbr data-mce-fragment=\"1\"\u003eIEEE 802.1Q-in-Q: VLAN Stacking\u003cbr data-mce-fragment=\"1\"\u003eIEEE 802.1s: Multiple Spanning Tree Protocol (MSTP)\u003cbr data-mce-fragment=\"1\"\u003eNumber of MST instances supported: 64\u003cbr data-mce-fragment=\"1\"\u003eIEEE 802.1w: Rapid Spanning Tree Protocol (RSTP)\u003cbr data-mce-fragment=\"1\"\u003eIEEE 802.1X: Port Access Control\u003cbr data-mce-fragment=\"1\"\u003eIEEE 802.3: 10BASE-T\u003cbr data-mce-fragment=\"1\"\u003eIEEE 802.3u: 100BASE-TX\u003cbr data-mce-fragment=\"1\"\u003eIEEE 802.3ab: 1000BASE-T\u003cbr data-mce-fragment=\"1\"\u003eIEEE 802.3z: 1000BASE-X\u003cbr data-mce-fragment=\"1\"\u003eIEEE 802.3af: PoE\u003cbr data-mce-fragment=\"1\"\u003eIEEE 802.3at: PoE+\u003cbr data-mce-fragment=\"1\"\u003eIEEE 802.3ad: Link Aggregation Control Protocol (LACP)\u003cbr data-mce-fragment=\"1\"\u003eIEEE 802.3x: Pause Frames\/Flow Control\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd width=\"395\" data-mce-fragment=\"1\"\u003eLayer 3 Features: IPv4\u003c\/td\u003e\n\u003ctd width=\"379\" data-mce-fragment=\"1\"\u003eMaximum number of ARP entries: 1,500\u003cbr data-mce-fragment=\"1\"\u003eMaximum number of IPv4 unicast routes in hardware: 512\u003cbr data-mce-fragment=\"1\"\u003eprefixes; 4,096 host routes\u003cbr data-mce-fragment=\"1\"\u003eMaximum number of IPv4 multicast routes in hardware: 2,048\u003cbr data-mce-fragment=\"1\"\u003egroups; 2,048 multicast routes\u003cbr data-mce-fragment=\"1\"\u003eRouting Protocols: RIP v1\/v2, OSPF v1\/v2\u003cbr data-mce-fragment=\"1\"\u003eStatic routing\u003cbr data-mce-fragment=\"1\"\u003eRouting policy\u003cbr data-mce-fragment=\"1\"\u003eBidirectional Forwarding Detection (BFD) with slow timers (\u0026gt; 3\u003cbr data-mce-fragment=\"1\"\u003esec)\u003cbr data-mce-fragment=\"1\"\u003eIP directed broadcast\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd width=\"395\" data-mce-fragment=\"1\"\u003eLayer 3 Features: IPv6\u003c\/td\u003e\n\u003ctd width=\"379\" data-mce-fragment=\"1\"\u003eMaximum number of Neighbor Discovery (ND) entries: 1,500\u003cbr data-mce-fragment=\"1\"\u003eMaximum number of IPv6 unicast routes in hardware: 512\u003cbr data-mce-fragment=\"1\"\u003eprefixes; 2,048 host routes\u003cbr data-mce-fragment=\"1\"\u003eMaximum number of IPv6 multicast routes in hardware: 1,024\u003cbr data-mce-fragment=\"1\"\u003egroups; 1,024 multicast routes\u003cbr data-mce-fragment=\"1\"\u003eNeighbor discovery, system logging, Telnet, SSH, SNMP,\u003cbr data-mce-fragment=\"1\"\u003eNetwork Time Protocol (NTP), Domain Name System (DNS)\u003cbr data-mce-fragment=\"1\"\u003eStatic routing\u003cbr data-mce-fragment=\"1\"\u003eRouting protocols: RIPng, OSPF v3\u003cbr data-mce-fragment=\"1\"\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd width=\"395\" data-mce-fragment=\"1\"\u003eAccess Control Lists (ACLs) (Junos OS Firewall Filters)\u003c\/td\u003e\n\u003ctd width=\"379\" data-mce-fragment=\"1\"\u003ePort-based ACL (PACL)256 ingress; 256 egress\u003cbr data-mce-fragment=\"1\"\u003eVLAN-based ACL (VACL)256 ingress; 256 egress\u003cbr data-mce-fragment=\"1\"\u003eRouter-based ACL (RACL)256 ingress; 512 egress\u003cbr data-mce-fragment=\"1\"\u003eACL entries (ACE) in hardware per system: 2,000\u003cbr data-mce-fragment=\"1\"\u003eACL counter for denied packets\u003cbr data-mce-fragment=\"1\"\u003eACL counter for permitted packets\u0026gt;\u003cbr data-mce-fragment=\"1\"\u003eAbility to add\/remove\/change ACL entries in middle of list\u003cbr data-mce-fragment=\"1\"\u003e(ACL editing)\u003cbr data-mce-fragment=\"1\"\u003eL2-L4 ACL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd width=\"395\" data-mce-fragment=\"1\"\u003eAccess Security\u003c\/td\u003e\n\u003ctd width=\"379\" data-mce-fragment=\"1\"\u003eMAC limiting\u003cbr data-mce-fragment=\"1\"\u003eAllowed MAC addressesconfigurable per port\u003cbr data-mce-fragment=\"1\"\u003eMAC limiting\u003cbr data-mce-fragment=\"1\"\u003eAllowed MAC addressesconfigurable per port\u003cbr data-mce-fragment=\"1\"\u003eSticky MAC (persistent MAC address learning)\u003cbr data-mce-fragment=\"1\"\u003eDynamic ARP inspection (DAI)\u003cbr data-mce-fragment=\"1\"\u003eProxy ARP\u003cbr data-mce-fragment=\"1\"\u003eStatic ARP support\u003cbr data-mce-fragment=\"1\"\u003eDHCP snooping\u003cbr data-mce-fragment=\"1\"\u003e802.1X port-based\u003cbr data-mce-fragment=\"1\"\u003e802.1X multiple supplicants\u003cbr data-mce-fragment=\"1\"\u003e802.1X with VLAN assignment\u003cbr data-mce-fragment=\"1\"\u003e802.1X with authentication bypass access (based on host MAC\u003cbr data-mce-fragment=\"1\"\u003eaddress)\u003cbr data-mce-fragment=\"1\"\u003e802.1X with VoIP VLAN support\u003cbr data-mce-fragment=\"1\"\u003e802.1X dynamic access control list (ACL) based on RADIUS\u003cbr data-mce-fragment=\"1\"\u003eattributes\u003cbr data-mce-fragment=\"1\"\u003e802.1X Supported EAP types: Message Digest 5 (MD5),\u003cbr data-mce-fragment=\"1\"\u003eTransport Layer Security (TLS), Tunneled Transport Layer\u003cbr data-mce-fragment=\"1\"\u003eSecurity (TTLS), Protected Extensible Authentication Protocol\u003cbr data-mce-fragment=\"1\"\u003e(PEAP)\u003cbr data-mce-fragment=\"1\"\u003eIPv6 RA Guard\u003cbr data-mce-fragment=\"1\"\u003eIPv6 Neighbor Discovery Inspection\u003cbr data-mce-fragment=\"1\"\u003eCaptive Portal\u003cbr data-mce-fragment=\"1\"\u003eStatic MAC authentication\u003cbr data-mce-fragment=\"1\"\u003eMAC-RADIUS\u003cbr data-mce-fragment=\"1\"\u003eControl plane DoS protection\u003cbr data-mce-fragment=\"1\"\u003eFallback Authentication\u003cbr data-mce-fragment=\"1\"\u003eTrusted Network Connect (TNC) certified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd width=\"395\" data-mce-fragment=\"1\"\u003eHigh Availability\u003c\/td\u003e\n\u003ctd width=\"379\" data-mce-fragment=\"1\"\u003eLink Aggregation\u003cbr data-mce-fragment=\"1\"\u003e802.3ad (LACP) support:\u003cbr data-mce-fragment=\"1\"\u003e- Number of LAGs supported: 128\u003cbr data-mce-fragment=\"1\"\u003e- Maximum number of ports per LAG: 8\u003cbr data-mce-fragment=\"1\"\u003eTagged ports support in LAG\u003cbr data-mce-fragment=\"1\"\u003eUplink failure detection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd width=\"395\" data-mce-fragment=\"1\"\u003eQuality of Service (QoS)\u003c\/td\u003e\n\u003ctd width=\"379\" data-mce-fragment=\"1\"\u003eLayer 2 QoS\u003cbr data-mce-fragment=\"1\"\u003eLayer 3 QoS\u003cbr data-mce-fragment=\"1\"\u003eIngress policing: 2 rate 3 color\u003cbr data-mce-fragment=\"1\"\u003eHardware queues per port: 8\u003cbr data-mce-fragment=\"1\"\u003eScheduling methods (egress): Strict Priority (SP), shaped-deficit\u003cbr data-mce-fragment=\"1\"\u003eweighted round-robin (SDWRR)\u003cbr data-mce-fragment=\"1\"\u003e802.1p: DSCP\/IP precedence trust and marking\u003cbr data-mce-fragment=\"1\"\u003eL2-L4 classification criteria: Interface, MAC address, Ethertype,\u003cbr data-mce-fragment=\"1\"\u003e802.1p, VLAN, IP address, DSCP\/IP precedence, TCP\/UDP\u003cbr data-mce-fragment=\"1\"\u003eport numbers\u003cbr data-mce-fragment=\"1\"\u003eCongestion avoidance capabilities: Tail drop and WRED\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd width=\"395\" data-mce-fragment=\"1\"\u003eMulticast\u003c\/td\u003e\n\u003ctd width=\"379\" data-mce-fragment=\"1\"\u003eInternet Group Management Protocol (IGMP) snooping\u003cbr data-mce-fragment=\"1\"\u003eentries: 2,000\u003cbr data-mce-fragment=\"1\"\u003eIGMP: v1, v2, v3\u003cbr data-mce-fragment=\"1\"\u003eIGMP snooping\u003cbr data-mce-fragment=\"1\"\u003ePIM sparse mode (PIM SM), PIM source-specific multicast (PIM\u003cbr data-mce-fragment=\"1\"\u003eSSM), PIM dense mode (PIM DM)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd width=\"395\" data-mce-fragment=\"1\"\u003eDevice Management and Operations\u003c\/td\u003e\n\u003ctd width=\"379\" data-mce-fragment=\"1\"\u003eJunos OS CLI\u003cbr data-mce-fragment=\"1\"\u003eDevice Management and Operations\u003cbr data-mce-fragment=\"1\"\u003eJunos OS CLI\u003cbr data-mce-fragment=\"1\"\u003eJunos Web interface (J-Web)\u003cbr data-mce-fragment=\"1\"\u003eOut-of-band management: Serial, 10\/100BASE-T Ethernet\u003cbr data-mce-fragment=\"1\"\u003eASCII configuration\u003cbr data-mce-fragment=\"1\"\u003eRescue configuration\u003cbr data-mce-fragment=\"1\"\u003eConfiguration rollback\u003cbr data-mce-fragment=\"1\"\u003eImage rollback\u003cbr data-mce-fragment=\"1\"\u003eSimple Network Management Protocol (SNMP): v1, v2c, v3\u003cbr data-mce-fragment=\"1\"\u003eRemote monitoring (RMON) (RFC 2819) Groups 1, 2, 3, 9\u003cbr data-mce-fragment=\"1\"\u003eNetwork Time Protocol (NTP)\u003cbr data-mce-fragment=\"1\"\u003eDHCP server\u003cbr data-mce-fragment=\"1\"\u003eDHCP client and DHCP proxy\u003cbr data-mce-fragment=\"1\"\u003eDHCP relay and helper\u003cbr data-mce-fragment=\"1\"\u003eRADIUS authentication\u003cbr data-mce-fragment=\"1\"\u003eTACACS+ authentication\u003cbr data-mce-fragment=\"1\"\u003eSSHv2\u003cbr data-mce-fragment=\"1\"\u003eSecure copy\u003cbr data-mce-fragment=\"1\"\u003eHTTP\/HTTPs\u003cbr data-mce-fragment=\"1\"\u003eDNS resolver\u003cbr data-mce-fragment=\"1\"\u003eSystem log logging\u003cbr data-mce-fragment=\"1\"\u003eTemperature sensor\u003cbr data-mce-fragment=\"1\"\u003eConfiguration backup via FTP\/secure copy\u003cbr data-mce-fragment=\"1\"\u003eInterface range\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eManagement and Analytics Platforms\u003c\/td\u003e\n\u003ctd width=\"379\" data-mce-fragment=\"1\"\u003eJuniper Mist Wired Assurance for Campus \u003cbr data-mce-fragment=\"1\"\u003eJunos Space® Network Director for Campus \u003cbr data-mce-fragment=\"1\"\u003eJunos Space® Management\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eOperating temperature\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e32° to 104° F (0° to 40° C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eStorage temperature\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e-40° to 158° F (-40° to 70° C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eOperating altitude\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eup to 5.000 ft (1524 m)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eNon-operating altitude\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eup to 16,000 ft (4877 m)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eRelative humidity operating\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e10% to 85% (noncondensing)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eRelative humidity non-operating\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e0% to 95% (noncondensing)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eSafety Certifications\u003c\/td\u003e\n\u003ctd width=\"379\" data-mce-fragment=\"1\"\u003eUL-UL60950-1 (Second Edition)\u003cbr data-mce-fragment=\"1\"\u003eC-UL to CAN\/CSA 22.2 No.60950-1 (Second Edition)\u003cbr data-mce-fragment=\"1\"\u003eTUV\/GS to EN 60950-1 (Second Edition)\u003cbr data-mce-fragment=\"1\"\u003eCB-IEC60950-1 (Second Edition with all country deviations)\u003cbr data-mce-fragment=\"1\"\u003eEN 60825-1 (Second Edition)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eElectromagnetic Compatibility Certifications\u003c\/td\u003e\n\u003ctd width=\"379\" data-mce-fragment=\"1\"\u003eFCC 47CFR Part 15 Class A\u003cbr data-mce-fragment=\"1\"\u003eEN 55022 Class A\u003cbr data-mce-fragment=\"1\"\u003eICES-003 Class A\u003cbr data-mce-fragment=\"1\"\u003eVCCI Class A\u003cbr data-mce-fragment=\"1\"\u003eAS\/NZS CISPR 22 Class A\u003cbr data-mce-fragment=\"1\"\u003eCISPR 22 Class A\u003cbr data-mce-fragment=\"1\"\u003eEN 55024\u003cbr data-mce-fragment=\"1\"\u003eEN 300386\u003cbr data-mce-fragment=\"1\"\u003eCE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eTelecom Quality Management\u003c\/td\u003e\n\u003ctd width=\"379\" data-mce-fragment=\"1\"\u003eTL9000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eTelco\u003c\/td\u003e\n\u003ctd width=\"379\" data-mce-fragment=\"1\"\u003eCLEI code\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e[\/specifications]\u003cbr\u003e\u003cbr\u003e[accesories]\u003c\/p\u003e\n\u003ctable width=\"434\" data-mce-fragment=\"1\"\u003e\n\u003ctbody data-mce-fragment=\"1\"\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd width=\"434\" colspan=\"2\" data-mce-fragment=\"1\"\u003eAccessories and License Upgrade PIDs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd width=\"154\" data-mce-fragment=\"1\"\u003eEX-CBL-CON-USB\u003c\/td\u003e\n\u003ctd width=\"280\" data-mce-fragment=\"1\"\u003eConsole cable with USB Type A and mini-B connectors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd width=\"154\" data-mce-fragment=\"1\"\u003eEX2300-C-CBL-GRD\u003c\/td\u003e\n\u003ctd width=\"280\" data-mce-fragment=\"1\"\u003eCable guard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd width=\"154\" data-mce-fragment=\"1\"\u003eEX2300-C-MGNT-MNT\u003c\/td\u003e\n\u003ctd width=\"280\" data-mce-fragment=\"1\"\u003eMagnet mount\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd width=\"154\" data-mce-fragment=\"1\"\u003eEX2300-C-RMK\u003c\/td\u003e\n\u003ctd width=\"280\" data-mce-fragment=\"1\"\u003eRack-mount kit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd colspan=\"2\" data-mce-fragment=\"1\"\u003eSubscription Licenses\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd width=\"154\" data-mce-fragment=\"1\"\u003eS-EX-A-C1-3\u003c\/td\u003e\n\u003ctd width=\"280\" data-mce-fragment=\"1\"\u003eSoftware, EX Series Advanced license, Class 1 (12 ports), includes Wired Assurance subscription for EX Series 12-port switches, 3 year\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd width=\"154\" data-mce-fragment=\"1\"\u003eS-EX-A-C1-5\u003c\/td\u003e\n\u003ctd width=\"280\" data-mce-fragment=\"1\"\u003eSoftware, EX Series Advanced license, Class 1 (12 ports), includes Wired Assurance subscription for EX Series 12-port switches, 5 year\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd width=\"154\" data-mce-fragment=\"1\"\u003eS-EX-A-C1-3-COR\u003c\/td\u003e\n\u003ctd width=\"280\" data-mce-fragment=\"1\"\u003eSoftware, EX Series Advanced license, Class 1 (12 ports), includes Wired Assurance subscription for EX Series 12-port switches with SVC CORE support, 3 year\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd width=\"154\" data-mce-fragment=\"1\"\u003eS-EX-A-C1-5-COR\u003c\/td\u003e\n\u003ctd width=\"280\" data-mce-fragment=\"1\"\u003eSoftware, EX Series Advanced license, Class 1 (12 ports), includes Wired Assurance subscription for EX Series 12-port switches with SVC CORE support, 5 year\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd colspan=\"2\" data-mce-fragment=\"1\"\u003ePerpetual Licenses\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd width=\"154\" data-mce-fragment=\"1\"\u003eS-EX-A-C2-P\u003c\/td\u003e\n\u003ctd width=\"280\" data-mce-fragment=\"1\"\u003eSoftware, EX Series Advanced license, Class 2 Perpetual license for 12-port switches\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd width=\"154\" data-mce-fragment=\"1\"\u003eEX-12-EFL\u003c\/td\u003e\n\u003ctd width=\"280\" data-mce-fragment=\"1\"\u003eEnhanced Feature License for EX2300 12 port switches\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd width=\"434\" colspan=\"2\" data-mce-fragment=\"1\"\u003eOptics\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd width=\"154\" data-mce-fragment=\"1\"\u003eEX-SFP-10GE-USR\u003c\/td\u003e\n\u003ctd width=\"280\" data-mce-fragment=\"1\"\u003eSFP+ 10-Gigabit Ethernet Ultra Short Reach Optics, 850 nm for 10m on OM1, 20m on OM2, 100m on OM3 multimode fiber\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd width=\"154\" data-mce-fragment=\"1\"\u003eEX-SFP-10GE-DAC-1M\u003c\/td\u003e\n\u003ctd width=\"280\" data-mce-fragment=\"1\"\u003eSFP+ 10-Gigabit Ethernet Direct Attach Copper (twinax copper cable), 1m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd width=\"154\" data-mce-fragment=\"1\"\u003eEX-SFP-10GE-SR\u003c\/td\u003e\n\u003ctd width=\"280\" data-mce-fragment=\"1\"\u003eSFP+ 10GBASE-LR; LC connector; 1310 nm; 10km reach on single-mode fiber\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd width=\"154\" data-mce-fragment=\"1\"\u003eEX-SFP-10GE-LR\u003c\/td\u003e\n\u003ctd width=\"280\" data-mce-fragment=\"1\"\u003eSFP+ 10GBASE-LR; LC connector; 1310 nm; 10km reach on single-mode fiber\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd width=\"154\" data-mce-fragment=\"1\"\u003eEX-SFP-10GE-DAC-3M\u003c\/td\u003e\n\u003ctd width=\"280\" data-mce-fragment=\"1\"\u003eSFP+ 10-Gigabit Ethernet Direct Attach Copper (twinax copper cable), 3m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd width=\"154\" data-mce-fragment=\"1\"\u003eEX-SFP-10GE-DAC-5M\u003c\/td\u003e\n\u003ctd width=\"280\" data-mce-fragment=\"1\"\u003eSFP+ 10-Gigabit Ethernet Direct Attach Copper (twinax copper cable), 5m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd width=\"154\" data-mce-fragment=\"1\"\u003eEX-SFP-1GE-SX\u003c\/td\u003e\n\u003ctd width=\"280\" data-mce-fragment=\"1\"\u003eSFP 1000BASE-SX; LC connector; 850 nm; 550m reach on multimode fiber\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd width=\"154\" data-mce-fragment=\"1\"\u003eEX-SFP-1GE-SX-ET\u003c\/td\u003e\n\u003ctd width=\"280\" data-mce-fragment=\"1\"\u003eExtended Temperature SFP 1000BASE-SX; LC connector; 850 nm; 550m reach on multimode fiber\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd width=\"154\" data-mce-fragment=\"1\"\u003eEX-SFP-1GE-LX\u003c\/td\u003e\n\u003ctd width=\"280\" data-mce-fragment=\"1\"\u003eSFP 1000BASE-LX; LC connector; 1310 nm; 10 km reach on single-mode fiber\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd width=\"154\" data-mce-fragment=\"1\"\u003eEX-SFP-1GE-LH\u003c\/td\u003e\n\u003ctd width=\"280\" data-mce-fragment=\"1\"\u003eSFP 1000BASE-LH Gigabit Ethernet Optics, 1550 nm for 70 km transmission on single-mode fiber\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd width=\"154\" data-mce-fragment=\"1\"\u003eEX-SFP-1GE-T\u003c\/td\u003e\n\u003ctd width=\"280\" data-mce-fragment=\"1\"\u003eSFP 10\/100\/1000BASE-T Copper Transceiver Module for up to 100m transmission on Category\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd width=\"154\" data-mce-fragment=\"1\"\u003eEX-SFP-1GE-LX40K\u003c\/td\u003e\n\u003ctd width=\"280\" data-mce-fragment=\"1\"\u003eSFP 1000BASE-LX Gigabit Ethernet Optics, 1310 nm for 40 km transmission on single-mode fiber\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd width=\"154\" data-mce-fragment=\"1\"\u003eEX-SFP-GE10KT13R14\u003c\/td\u003e\n\u003ctd width=\"280\" data-mce-fragment=\"1\"\u003eSFP 1000BASE-BX Gigabit Ethernet Optics, Tx 1310 nm\/Rx 1490 nm for 10 km transmission on single strand of single-mode fiber\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd width=\"154\" data-mce-fragment=\"1\"\u003eEX-SFP-GE10KT14R13\u003c\/td\u003e\n\u003ctd width=\"280\" data-mce-fragment=\"1\"\u003eSFP 1000BASE-BX Gigabit Ethernet Optics, Tx 1490 nm\/Rx 1310 nm for 10 km transmission on single strand of single-mode fiber\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd width=\"154\" data-mce-fragment=\"1\"\u003eEX-SFP-GE10KT13R15\u003c\/td\u003e\n\u003ctd width=\"280\" data-mce-fragment=\"1\"\u003eSFP 1000BASE-BX Gigabit Ethernet Optics, Tx 1310 nm\/Rx 1550 nm for 10 km transmission on single strand of single-mode fiber\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd width=\"154\" data-mce-fragment=\"1\"\u003eEX-SFP-GE10KT15R13\u003c\/td\u003e\n\u003ctd width=\"280\" data-mce-fragment=\"1\"\u003eSFP 1000BASE-BX Gigabit Ethernet Optics, Tx 1550 nm\/Rx 1310 nm for 10 km transmission on single strand of single-mode fiber\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd width=\"154\" data-mce-fragment=\"1\"\u003eEX-SFP-GE40KT13R15\u003c\/td\u003e\n\u003ctd width=\"280\" data-mce-fragment=\"1\"\u003eSFP 1000BASE-BX Gigabit Ethernet Optics, Tx 1310 nm\/Rx 1550 nm for 40 km transmission on single strand of single-mode fiber\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd width=\"154\" data-mce-fragment=\"1\"\u003eEX-SFP-GE40KT15R13\u003c\/td\u003e\n\u003ctd width=\"280\" data-mce-fragment=\"1\"\u003eSFP 1000BASE-BX Gigabit Ethernet Optics, Tx 1550 nm\/Rx 1310 nm for 40 km transmission on single strand of single-mode fiber\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd width=\"154\" data-mce-fragment=\"1\"\u003eEX-SFP-GE80KCW1470\u003c\/td\u003e\n\u003ctd width=\"280\" data-mce-fragment=\"1\"\u003eSFP Gigabit Ethernet CWDM, LC connector; 1470 nm, 80 km reach on single-mode fiber\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd width=\"154\" data-mce-fragment=\"1\"\u003eEX-SFP-GE80KCW1490\u003c\/td\u003e\n\u003ctd width=\"280\" data-mce-fragment=\"1\"\u003eSFP Gigabit Ethernet CWDM, LC connector; 1490 nm, 80 km reach on single-mode fiber\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd width=\"154\" data-mce-fragment=\"1\"\u003eEX-SFP-GE80KCW1510\u003c\/td\u003e\n\u003ctd width=\"280\" data-mce-fragment=\"1\"\u003eSFP Gigabit Ethernet CWDM, LC connector; 1510 nm, 80 km reach on single-mode fiber\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd width=\"154\" data-mce-fragment=\"1\"\u003eEX-SFP-GE80KCW1530\u003c\/td\u003e\n\u003ctd width=\"280\" data-mce-fragment=\"1\"\u003eSFP Gigabit Ethernet CWDM, LC connector; 1530 nm, 80 km reach on single-mode fiber\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd width=\"154\" data-mce-fragment=\"1\"\u003eEX-SFP-GE80KCW1550\u003c\/td\u003e\n\u003ctd width=\"280\" data-mce-fragment=\"1\"\u003eSFP Gigabit Ethernet CWDM, LC connector; 1550 nm, 80 km reach on single-mode fiber\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd width=\"154\" data-mce-fragment=\"1\"\u003eEX-SFP-GE80KCW1570\u003c\/td\u003e\n\u003ctd width=\"280\" data-mce-fragment=\"1\"\u003eSFP Gigabit Ethernet CWDM, LC connector; 1570 nm, 80 km reach on single-mode fiber\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd width=\"154\" data-mce-fragment=\"1\"\u003eEX-SFP-GE80KCW1590\u003c\/td\u003e\n\u003ctd width=\"280\" data-mce-fragment=\"1\"\u003eSFP Gigabit Ethernet CWDM, LC connector; 1590 nm, 80 km reach on single-mode fiber\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd width=\"154\" data-mce-fragment=\"1\"\u003eEX-SFP-GE80KCW1610\u003c\/td\u003e\n\u003ctd width=\"280\" data-mce-fragment=\"1\"\u003eSFP Gigabit Ethernet CWDM, LC connector; 1610 nm, 80 km reach on single-mode fiber\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e[\/accesories]\u003c\/p\u003e\n\u003ch2 data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003eJuniper EX2300-C-12T-VC Switch with Virtual Chassis License\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003eThe Juniper Networks EX2300-C-12T-VC Ethernet Switch provides a cost-effective, introductory-level solution in a small, fanless design for access layer deployments in branch, retail, and workgroup settings. The EX2300-C is compatible with Juniper's distinctive Virtual Chassis technology, allowing for the management of up to four interconnected EX2300-C switches as a unified logical device. This feature provides a scalable, incremental solution for expanding network environments. The EX2300-C-12T-VC model is equipped with 12 ports of 10\/100\/1000BASE-T, along with 2 x 1\/10GbE SFP\/SFP+ and includes a Virtual Chassis License (optics are sold separately)\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003eQuick Specs:\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\n\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003cspan data-mce-fragment=\"1\"\u003e12x 10\/100\/1000BASE-T\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\n\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003cspan data-mce-fragment=\"1\"\u003e2x 1\/10GbE SFP\/SFP+ ports uplink (optics sold separately)\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\n\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003cspan data-mce-fragment=\"1\"\u003e2 GB with ECC RAM\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\n\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003cspan data-mce-fragment=\"1\"\u003eVirtual Chassis License\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003ePlease see the related tabs for the EX2300-C-12T-VC datasheet and compatible accessories.\u003c\/span\u003e\u003c\/p\u003e","brand":"Juniper","offers":[{"title":"Default Title","offer_id":48013263864025,"sku":"EX2300-C-12T-VC-NEW","price":826.9,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0016\/5327\/6707\/files\/ex2300-c-12t-vc_1_56751a1d-ff46-4310-a903-250e6b81d89c.webp?v=1771852915","url":"https:\/\/www.aloinfousa.com\/es\/products\/juniper-ex2300-c-12t-vc-switch-with-virtual-chassis-license-3s9d4","provider":"aloinfousa.com","version":"1.0","type":"link"}