{"title":"Endress+Hauser Prowirl Vortex Flowmeters","description":"\u003cp\u003eGenuine Endress+Hauser \u003cstrong\u003eProwirl\u003c\/strong\u003e vortex flowmeters for steam, gas and liquid flow measurement. Factory-sealed, full warranty, shipped \u003cstrong\u003eDDP worldwide\u003c\/strong\u003e, POs accepted. Request a quote below.\u003c\/p\u003e","products":[{"product_id":"endress-hauser-7f2c-proline-prowirl-f200-vortex-flowmeter","title":"Endress+Hauser 7F2C Proline Prowirl F200 Vortex Flowmeter","description":"\u003ch1\u003eOverview\u003c\/h1\u003e\u003cp\u003eEndress+Hauser Proline Prowirl F200 Vortex Flowmeter is a versatile flowmeter with detection of wet steam conditions and best-in-class accuracy.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eSpecs at a glance\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e* Max. measurement error \u003cbr\u003eVolume flow (liquid): ±0.75 % \u003cbr\u003eVolume flow (optional): ±0.65 % \u003cbr\u003eVolume flow (steam, gas): ±1.00 % \u003cbr\u003eMass flow (saturated steam): ±1.7% (temperature compensated); ±1.5% (temperature\/pressure compensated) \u003cbr\u003eMass flow (superheated steam, gas): ±1.5 (temperature\/pressure compensated); ±1.7% (temperature compensated + external pressure \u003cbr\u003ecompensation) \u003cbr\u003eMass flow (liquid): ±0.85% \u003cbr\u003e* Measuring range \u003cbr\u003eLiquid: 0.076 to 2100 m³\/h (0.045 to 1300 ft³\/min) \u003cbr\u003edepending on medium: water with 1 bar a, 20 °C (14.5 psi a, 68° F) \u003cbr\u003eSteam, gas: 0.39 to 28000 m³\/h (0.23 to 17000 ft³\/min) \u003cbr\u003edepending on medium: steam with 180 °C, 10 bar a (356 °F, 145 psi a); air with 25 °C, 4.4 bar a (77 °F, 63.8 psi a) \u003cbr\u003e* Medium temperature range \u003cbr\u003eStandard: –40 to +260 °C (–40 to +500 °F) \u003cbr\u003eHigh\/low temperature (option): –200 to +400 °C (–328 to +752 °F) \u003cbr\u003e* Max. process pressure \u003cbr\u003ePN 100, Class 600, 20K \u003cbr\u003e* Wetted materials \u003cbr\u003eMeasuring tube: 1.4408 (CF3M); CX2MW similar to Alloy C22, 2.4602 \u003cbr\u003eDSC sensor: 1.4404 (316\/316L); UNS N06022 similar to Alloy C22, 2.4602 \u003cbr\u003eProcess connection: 1.4404\/F316\/F316L); 2.4602\u003c\/p\u003e\u003ch1\u003eField of application\u003c\/h1\u003e\u003cp\u003eProwirl F is the multivariable flowmeter with inline wet steam measurement. Its calibration option PremiumCal guarantees excellent measuring accuracy and highest plant availability at low flow rates of gas, steam and liquids. With genuine loop-powered technology, Prowirl F 200 enables cost-effective and seamless integration into existing infrastructures. It offers highest operational safety in hazardous areas. Heartbeat Technology enables process safety at all times.\u003cbr\u003e* Preferred measuring principle for wet\/saturated\/superheated steam, gases \u0026amp; liquids (also cryogenic)\u003cbr\u003e* Suitable for a wide range of applications; optimized for steam applications\u003cbr\u003eDevice properties\u003cbr\u003e* Wet steam capabilities for DN 25 to 300 (1 to 12\")\u003cbr\u003e* Flexible positioning of pressure cell\u003cbr\u003e* Industrial siphon design for pressure measurement\u003cbr\u003e* Display module with data transfer function\u003cbr\u003e* Robust dual-compartment housing\u003cbr\u003e* Plant safety: worldwide approvals (SIL, Haz. area)\u003c\/p\u003e\u003ch1\u003eBenefits\u003c\/h1\u003e\u003cp\u003e * Easy energy management – integrated temperature and pressure measurement for steam and gases\u003cbr\u003e* Reliable, secure measurement technology – compliance with international Vortex standard ISO 12764\u003cbr\u003e* Same accuracy down to Re 10 000 – most linear Vortex meter body\u003cbr\u003e* Long-term stability – robust drift-free capacitive sensor\u003cbr\u003e* Convenient device wiring – separate connection compartment, various Ethernet options\u003cbr\u003e* Safe operation – no need to open the device\u003cbr\u003e* Integrated verification – Heartbeat Technology\u003c\/p\u003e\u003ch1\u003eSpecification\u003c\/h1\u003e\u003cfigure class=\"table\"\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eitem\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003evalue\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eWarranty\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e1 Year\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eCustomized support\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eOEM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003ePlace of Origin\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eGermany\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eBrand Name\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eEndress+Hauser\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eModel Number\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eProwirl F200\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eType\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eVortex Flowmeter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eProduct Headline\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eVersatile flowmeter with detection of wet steam conditions and best-in-class accuracy. \u003cbr\u003eEasy energy management – integrated temperature and pressure measurement for steam and gases. \u003cbr\u003eSuitable for a wide range of applications; optimized for steam applications.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eSensor Features\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eSpace-saving engineering – inlet run compensation. Same accuracy down to Re 10 000 – most linear Vortex meter body. Long-term \u003cbr\u003estability – robust drift-free capacitive sensor. \u003cbr\u003eWet steam capabilities for DN 25 to 300 (1 to 12\"). Flexible positioning of pressure cell. Industrial siphon design for pressure \u003cbr\u003emeasurement.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eTransmitter Features\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eConvenient device wiring – separate connection compartment. Safe operation – no need to open the device due to display with touch \u003cbr\u003econtrol, background lighting. Integrated verification – Heartbeat Technology. \u003cbr\u003eDisplay module with data transfer function. Robust dual-compartment housing. Plant safety: worldwide approvals (SIL, Haz. area).\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eNominal Diameter Range\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eDN 15 to 300 (½ to 12\")\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eWetted Materials\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eMeasuring tube: 1.4408 (CF3M); CX2MW similar to Alloy C22, 2.4602 \u003cbr\u003eDSC sensor: 1.4404 (316\/316L); UNS N06022 similar to Alloy C22, 2.4602 \u003cbr\u003eProcess connection: 1.4404\/F316\/F316L); 2.4602\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eMeasured Variables\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eVolume flow, mass flow, corrected volume flow, energy flow, heat flow difference, temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eMax. Measurement Error\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eVolume flow (liquid): ±0.75 % \u003cbr\u003eVolume flow (optional): ±0.65 % \u003cbr\u003eVolume flow (steam, gas): ±1.00 % \u003cbr\u003eMass flow (saturated steam): ±1.7% (temperature compensated); ±1.5% (temperature\/pressure compensated) \u003cbr\u003eMass flow (superheated steam, gas): ±1.5 (temperature\/pressure compensated); ±1.7% (temperature compensated + external pressure \u003cbr\u003ecompensation) \u003cbr\u003eMass flow (liquid): ±0.85%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eMeasuring Range\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eLiquid: 0.076 to 2100 m³\/h (0.045 to 1300 ft³\/min) \u003cbr\u003edepending on medium: water with 1 bar a, 20 °C (14.5 psi a, 68° F) \u003cbr\u003eSteam, gas: 0.39 to 28000 m³\/h (0.23 to 17000 ft³\/min) \u003cbr\u003edepending on medium: steam with 180 °C, 10 bar a (356 °F, 145 psi a); air with 25 °C, 4.4 bar a (77 °F, 63.8 psi a)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eMax. Process Ppressure\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003ePN 100, Class 600, 20K\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eMedium Temperature Range\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eStandard: –40 to +260 °C (–40 to +500 °F) \u003cbr\u003eHigh\/low temperature (option): –200 to +400 °C (–328 to +752 °F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eAmbient Temperature Range\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eCompact version (standard): –40 to +80 °C (–40 to +176 °F) \u003cbr\u003eCompact version (option): –50 to +80 °C (–58 to +176 °F) \u003cbr\u003eRemote version (standard): –40 to +85 °C (–40 to +185 °F) \u003cbr\u003eRemote version (option): –50 to +85 °C (–58 to +185 °F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eSensor Housing Material\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eSensor connection housing: AlSi10Mg, coated; 1.4408 (CF3M)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eTransmitter Housing Material\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eAlSi10Mg, coated; 1.4404 (316L)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eDegree Of Protection\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eCompact version: IP66\/67, type 4X enclosure \u003cbr\u003eSensor remote version: IP66\/67, type 4X enclosure \u003cbr\u003eTransmitter remote version: IP66\/67, type 4X enclosure\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eDisplay\/Operation\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e4‐line backlit display with touch control (operation from outside) \u003cbr\u003eConfiguration via local display and operating tools possible \u003cbr\u003eRemote display available\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eOutputs\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e4‐20 mA HART (passive) \u003cbr\u003e4‐20 mA (passive) \u003cbr\u003ePulse\/frequency\/switch output (passive)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eInputs\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eCurrent Input 4‐20 mA (passive)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eDigital Communication\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eHART, PROFIBUS PA, FOUNDATION Fieldbus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003ePower Supply\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eDC 12 to 35 V (4‐20 mA HART with\/without pulse\/frequency\/switch output) \u003cbr\u003eDC 12 to 30 V (4‐20 mA HART, 4‐20 mA) \u003cbr\u003eDC 12 to 35 V (4‐20 mA HART, pulse\/frequency\/switch output, 4‐20 mA input) \u003cbr\u003eDC 9 to 32 V (PROFIBUS PA, pulse\/frequency\/switch output)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eHazardous Area Approvals\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eATEX, IECEx, cCSAus, JPN, EAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eProduct Safety\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eCE, C-TICK, EAC, UK Ex\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eFunctional Safety\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eFunctional safety according to IEC 61508, applicable in safety-relevant applications in accordance with IEC 61511\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eMetrological Approvals And Certificates\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eCalibration performed on accredited calibration facilities (acc. to ISO\/IEC 17025) \u003cbr\u003eHeartbeat Technology complies with the requirements for measurement traceability according to ISO 9001:2015 – Section 7.1.5.2 a \u003cbr\u003e(TÜV SÜD attestation)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eMarine aApprovals And Certificates\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eABS, LR, BV, DNV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003ePressure Approvals And Certificates\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003ePED, CRN, AD 2000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eMaterial Certificates\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e3.1 material \u003cbr\u003eNACE MR0175\/MR0103, PMI (on request); welding test acc. to ISO 15614‐1, similar to ASME IX (on request)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/figure\u003e\u003cp\u003e \u003c\/p\u003e","brand":"Endress+Hauser","offers":[{"title":"Default Title","offer_id":48020368228569,"sku":null,"price":3125.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0016\/5327\/6707\/files\/Endress_Hauser_7F2C_Proline_Prowirl_F_200_Vortex_Flowmeter.png?v=1771970605"},{"product_id":"endress-hauser-7d2c-proline-prowirl-d200-vortex-flowmeter","title":"Endress+Hauser 7D2C Proline Prowirl D200 Vortex Flowmeter","description":"\u003ch1\u003eOverview\u003c\/h1\u003e\u003cp\u003eEndress+Hauser 7D2C Proline Prowirl D200 Vortex Flowmeter is a cost-effective wafer flowmeter, available as compact or remote version.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eSpecs at a glance\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e* Max. measurement error\u003cbr\u003eVolume flow (liquid): ±0.75 %\u003cbr\u003eVolume flow (steam, gas): ±1.00 %\u003cbr\u003eMass flow (liquid): ±0.85%\u003cbr\u003eMass flow (steam, gas): ±1.7 %\u003cbr\u003e* Measuring range\u003cbr\u003eLiquid: 0.16 to 625 m³\/h (0.09 to 368 ft³\/min)\u003cbr\u003edepending on medium: water with 1 bar a, 20 °C (14.5 psi a, 68° F)\u003cbr\u003eSteam, gas: 2 to 8342 m³\/h (1.18 to 4910 ft³\/min)\u003cbr\u003edepending on medium: steam with 180 °C, 10 bar a (356 °F, 145 psi a); air with 25 °C, 4.4 bar a (77 °F, 63.8 psi a)\u003cbr\u003e* Medium temperature range\u003cbr\u003eStandard: –40 to +260 °C (–40 to +500 °F)\u003cbr\u003eHigh\/low temperature (option): –200 to +400 °C (–328 to +752 °F)\u003cbr\u003eHigh\/low temperature (on request): –200 to +450 °C (–328 to +842 °F)\u003cbr\u003e* Max. process pressure\u003cbr\u003ePN 40, Class 300, 20K\u003cbr\u003e* Wetted materials\u003cbr\u003eMeasuring tube: 1.4408 (CF3M)\u003cbr\u003eDSC sensor: 1.4435 (316\/316L)\u003c\/p\u003e\u003ch1\u003eField of application\u003c\/h1\u003e\u003cp\u003eThe Prowirl D sensor can be installed directly between flanges and thus serves as the functional device for applications in ancillary processes at little installation cost. With genuine loop-powered technology, Prowirl D 200 enables cost-effective and seamless integration into existing infrastructures. It offers highest operational safety in hazardous areas. Heartbeat Technology enables process safety at all times.\u003cbr\u003e* Preferred measuring principle for wet\/saturated\/superheated steam, gases \u0026amp; liquids (also cryogenic)\u003cbr\u003e* For all basic applications and for 1-to-1 replacement of orifice plates.\u003cbr\u003eDevice properties\u003cbr\u003e* Face-to-face length of 65 mm (2.56 in)\u003cbr\u003e* No flanges\u003cbr\u003e* Low weight\u003cbr\u003e* Display module with data transfer function\u003cbr\u003e* Robust dual-compartment housing\u003cbr\u003e* Plant safety: worldwide approvals (SIL, Haz. area)\u003c\/p\u003e\u003ch1\u003eBenefits\u003c\/h1\u003e\u003cp\u003e * Integrated temperature measurement for mass\/energy flow of saturated steam\u003cbr\u003e* Easy alignment of the sensor – included centering rings\u003cbr\u003e* High availability – proven robustness, resistance to vibrations, temperature shocks \u0026amp; water hammer\u003cbr\u003e* Long-term stability – robust drift-free capacitive sensor\u003cbr\u003e* Convenient device wiring – separate connection compartment\u003cbr\u003e* Safe operation – no need to open the device due to display with touch control, background lighting\u003cbr\u003e* Integrated verification – Heartbeat Technology\u003c\/p\u003e\u003ch1\u003eSpecification\u003c\/h1\u003e\u003cfigure class=\"table\"\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eitem\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003evalue\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eWarranty\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e1 Year\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eCustomized support\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eOEM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003ePlace of Origin\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eGermany\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eBrand Name\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eEndress+Hauser\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eModel Number\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eProwirl D200\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eType\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eVortex Flowmeter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eProduct Headline\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eCost-effective wafer flowmeter, available as compact or remote version. \u003cbr\u003eIntegrated temperature measurement for mass\/energy flow of saturated steam. \u003cbr\u003eFor all basic applications and for 1-to-1 replacement of orifice plates.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eSensor Features\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eEasy alignment of the sensor – included centering rings. High availability – proven robustness, resistance to vibrations, \u003cbr\u003etemperature shocks \u0026amp; water hammer. Long-term stability – robust drift-free capacitive sensor. \u003cbr\u003eFace-to-face length of 65 mm (2.56 in). No flanges. Low weight.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eTransmitter Features\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eConvenient device wiring – separate connection compartment. Safe operation – no need to open the device due to display with touch \u003cbr\u003econtrol, background lighting. Integrated verification – Heartbeat Technology. \u003cbr\u003eDisplay module with data transfer function. Robust dual-compartment housing. Plant safety: worldwide approvals (SIL, Haz. area).\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eNominal Diameter Range\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eDN 15 to 150 (½ to 6\")\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eWetted Materials\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eMeasuring tube: 1.4408 (CF3M) \u003cbr\u003eDSC sensor: 1.4435 (316\/316L)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eMeasured Variables\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eVolume flow, mass flow, corrected volume flow, energy flow, heat flow difference, temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eMax. Measurement Error\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eVolume flow (liquid): ±0.75 % \u003cbr\u003eVolume flow (steam, gas): ±1.00 % \u003cbr\u003eMass flow (liquid): ±0.85% \u003cbr\u003eMass flow (steam, gas): ±1.7 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eMeasuring Range\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eLiquid: 0.16 to 625 m³\/h (0.09 to 368 ft³\/min) \u003cbr\u003edepending on medium: water with 1 bar a, 20 °C (14.5 psi a, 68° F) \u003cbr\u003eSteam, gas: 2 to 8342 m³\/h (1.18 to 4910 ft³\/min) \u003cbr\u003edepending on medium: steam with 180 °C, 10 bar a (356 °F, 145 psi a); air with 25 °C, 4.4 bar a (77 °F, 63.8 psi a)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eMax. Process Ppressure\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003ePN 40, Class 300, 20K\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eMedium Temperature Range\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eStandard: –40 to +260 °C (–40 to +500 °F) \u003cbr\u003eHigh\/low temperature (option): –200 to +400 °C (–328 to +752 °F) \u003cbr\u003eHigh\/low temperature (on request): –200 to +450 °C (–328 to +842 °F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eAmbient Temperature Range\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eCompact version (standard): –40 to +80 °C (–40 to +176 °F) \u003cbr\u003eCompact version (option): –50 to +80 °C (–58 to +176 °F) \u003cbr\u003eRemote version (standard): –40 to +85 °C (–40 to +185 °F) \u003cbr\u003eRemote version (option): –50 to +85 °C (–58 to +185 °F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eSensor Housing Material\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eSensor connection housing: AlSi10Mg, coated; 1.4408 (CF3M)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eTransmitter Housing Material\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eAlSi10Mg, coated; 1.4404 (316L)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eDegree Of Protection\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eCompact version: IP66\/67, type 4X enclosure \u003cbr\u003eSensor remote version: IP66\/67, type 4X enclosure \u003cbr\u003eTransmitter remote version: IP66\/67, type 4X enclosure\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eDisplay\/Operation\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e4‐line backlit display with touch control (operation from outside) \u003cbr\u003eConfiguration via local display and operating tools possible \u003cbr\u003eRemote display available\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eOutputs\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e4‐20 mA HART (passive) \u003cbr\u003e4‐20 mA (passive) \u003cbr\u003ePulse\/frequency\/switch output (passive)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eInputs\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eCurrent input 4‐20 mA (passive)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eDigital Communication\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eHART, PROFIBUS PA, FOUNDATION Fieldbus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003ePower Supply\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eDC 12 to 35 V (4‐20 mA HART with\/without pulse\/frequency\/switch output) \u003cbr\u003eDC 12 to 30 V (4‐20 mA HART, 4‐20 mA) \u003cbr\u003eDC 12 to 35 V (4‐20 mA HART, pulse\/frequency\/switch output, 4‐20 mA input) \u003cbr\u003eDC 9 to 32 V (PROFIBUS PA, pulse\/frequency\/switch output)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eHazardous Area Approvals\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eATEX, IECEx, cCSAus, JPN, EAC, UK Ex\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eProduct Safety\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eCE, C-TICK, EAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eFunctional Safety\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eFunctional safety according to IEC 61508, applicable in safety-relevant applications in accordance with IEC 61511\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eMetrological Approvals And Certificates\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eCalibration performed on accredited calibration facilities (acc. to ISO\/IEC 17025) \u003cbr\u003eHeartbeat Technology complies with the requirements for measurement traceability according to ISO 9001:2015 – Section 7.1.5.2 a \u003cbr\u003e(TÜV SÜD attestation)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eMarine aApprovals And Certificates\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eABS, LR, BV, DNV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003ePressure Approvals And Certificates\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003ePED, CRN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eMaterial Certificates\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e3.1 material \u003cbr\u003eNACE MR0175\/MR0103, PMI (on request)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/figure\u003e\u003cp\u003e \u003c\/p\u003e","brand":"Endress+Hauser","offers":[{"title":"Default Title","offer_id":48020368195801,"sku":null,"price":2850.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0016\/5327\/6707\/files\/Endress_Hauser_7D2C_Proline_Prowirl_D_200_Vortex_Flowmeter.png?v=1771970606"},{"product_id":"endress-hauser-7o2c-proline-prowirl-o200-vortex-flowmeter","title":"Endress+Hauser 7O2C Proline Prowirl O200 Vortex Flowmeter","description":"\u003ch1\u003eOverview\u003c\/h1\u003e\u003cp\u003eEndress+Hauser Proline Prowirl O200 Vortex Flowmeter optimized for requirements of high-pressure mating pipes.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eSpecs at a glance\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e* Max. measurement error\u003cbr\u003eVolume flow (liquid): ±0.75 %\u003cbr\u003eVolume flow (steam, gas): ±1.00 %\u003cbr\u003eMass flow (saturated steam): ±1.7% (temperature compensated); ±1.5% (temperature\/pressure compensated)\u003cbr\u003eMass flow (superheated steam, gas): ±1.5 (temperature\/pressure compensated); ±1.7% (temperature compensated + external pressure\u003cbr\u003ecompensation)\u003cbr\u003eMass flow (liquid): ±0.85%\u003cbr\u003e* Measuring range\u003cbr\u003eLiquid: 0.1 to 1700 m³\/h (0.061 to 1000 ft³\/min)\u003cbr\u003edepending on medium: water with 1 bar a, 20 °C (14.5 psi a, 68° F)\u003cbr\u003eSteam, gas: 0.52 to 22000 m³\/h (0.31 to 13000 ft³\/min)\u003cbr\u003edepending on medium: steam with 180 °C, 10 bar a (356 °F, 145 psi a); air with 25 °C, 4.4 bar a (77 °F, 63.8 psi a)\u003cbr\u003e* Medium temperature range\u003cbr\u003eStandard: –40 to +260 °C (–40 to +500 °F)\u003cbr\u003eHigh\/low temperature (option): –200 to +400 °C (–328 to +752 °F)\u003cbr\u003e* Max. process pressure\u003cbr\u003ePN 250, Class 1500, 40K\u003cbr\u003e* Wetted materials\u003cbr\u003eMeasuring tube: 1.4408 (CF3M)\u003cbr\u003eDSC sensor: UNS N07718 similar to Alloy 718, 2.4668\u003cbr\u003eProcess connection: 1.4404\/F316\/F316L \u003c\/p\u003e\u003ch1\u003eField of application\u003c\/h1\u003e\u003cp\u003eProwirl O is ideally suited for reliable process control in demanding gas and steam applications with high process pressure.Moreover, its design ensures maximum safety in main and ancillary processes. With genuine loop-powered technology, Prowirl O 200 enables cost-effective and seamless integration into existing infrastructures. It offers highest operational safety in hazardous\u003cbr\u003eareas. Heartbeat Technology enables process safety at all times.\u003cbr\u003e* Preferred measuring principle for wet\/saturated\/superheated steam, gases \u0026amp; liquids (also cryogenic)\u003cbr\u003e* The specialist for applications with high process pressure\u003c\/p\u003e\u003cp\u003e\u003cbr\u003eDevice properties\u003cbr\u003e* Saturated steam mass flow up to PN 250 (Class 1500)\u003cbr\u003e* Full compliance with NACE (MR0175\/MR0103)\u003cbr\u003e* Flexible positioning of pressure cell\u003cbr\u003e* Display module with data transfer function\u003cbr\u003e* Robust dual-compartment housing\u003cbr\u003e* Plant safety: worldwide approvals (SIL, Haz. area)\u003c\/p\u003e\u003ch1\u003eBenefits\u003c\/h1\u003e\u003cp\u003e * Better process control – integrated temperature and pressure measurement for steam and gases\u003cbr\u003e* Increased mechanical integrity for flow measurement – special sensor design\u003cbr\u003e* Same accuracy down to Re 10 000 – most linear Vortex meter body\u003cbr\u003e* Long-term stability – robust drift-free capacitive sensor\u003cbr\u003e* Convenient device wiring – separate connection compartment, various Ethernet options\u003cbr\u003e* Safe operation – no need to open the device\u003cbr\u003e* Integrated verification – Heartbeat Technology\u003c\/p\u003e\u003ch1\u003eSpecification\u003c\/h1\u003e\u003cfigure class=\"table\"\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eitem\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003evalue\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eWarranty\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e1 Year\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eCustomized support\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eOEM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003ePlace of Origin\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eGermany\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eBrand Name\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eEndress+Hauser\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eModel Number\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eProwirl O200\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eType\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eVortex Flowmeter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eProduct Headline\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eFlowmeter optimized for requirements of high-pressure mating pipes. \u003cbr\u003eBetter process control – integrated temperature and pressure measurement for steam and gases. \u003cbr\u003eThe specialist for applications with high process pressure.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eSensor Features\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eIncreased mechanical integrity for flow measurement – special sensor design. Same accuracy down to Re 10 000 – most linear Vortex \u003cbr\u003emeter body. Long-term stability – robust drift-free capacitive sensor. \u003cbr\u003eSaturated steam mass flow up to PN 250 (Class 1500). Full compliance with NACE (MR0175\/MR0103). Flexible positioning of pressure \u003cbr\u003ecell.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eTransmitter Features\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eConvenient device wiring – separate connection compartment. Safe operation – no need to open the device due to display with touch \u003cbr\u003econtrol, background lighting. Integrated verification – Heartbeat Technology. \u003cbr\u003eDisplay module with data transfer function. Robust dual-compartment housing. Plant safety: worldwide approvals (SIL, Haz. area).\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eNominal Diameter Range\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eDN 15 to 300 (½ to 12\")\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eWetted Materials\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eMeasuring tube: 1.4408 (CF3M) \u003cbr\u003eDSC sensor: UNS N07718 similar to Alloy 718, 2.4668 \u003cbr\u003eProcess connection: 1.4404\/F316\/F316L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eMeasured Variables\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eVolume flow, mass flow, corrected volume flow, energy flow, heat flow difference, temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eMax. Measurement Error\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eVolume flow (liquid): ±0.75 % \u003cbr\u003eVolume flow (steam, gas): ±1.00 % \u003cbr\u003eMass flow (saturated steam): ±1.7% (temperature compensated); ±1.5% (temperature\/pressure compensated) \u003cbr\u003eMass flow (superheated steam, gas): ±1.5 (temperature\/pressure compensated); ±1.7% (temperature compensated + external pressure \u003cbr\u003ecompensation) \u003cbr\u003eMass flow (liquid): ±0.85%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eMeasuring Range\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eLiquid: 0.1 to 1700 m³\/h (0.061 to 1000 ft³\/min) \u003cbr\u003edepending on medium: water with 1 bar a, 20 °C (14.5 psi a, 68° F) \u003cbr\u003eSteam, gas: 0.52 to 22000 m³\/h (0.31 to 13000 ft³\/min) \u003cbr\u003edepending on medium: steam with 180 °C, 10 bar a (356 °F, 145 psi a); air with 25 °C, 4.4 bar a (77 °F, 63.8 psi a)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eMax. Process Ppressure\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003ePN 250, Class 1500, 40K\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eMedium Temperature Range\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eStandard: –40 to +260 °C (–40 to +500 °F) \u003cbr\u003eHigh\/low temperature (option): –200 to +400 °C (–328 to +752 °F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eAmbient Temperature Range\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eCompact version (standard): –40 to +80 °C (–40 to +176 °F) \u003cbr\u003eCompact version (option): –50 to +80 °C (–58 to +176 °F) \u003cbr\u003eRemote version (standard): –40 to +85 °C (–40 to +185 °F) \u003cbr\u003eRemote version (option): –50 to +85 °C (–58 to +185 °F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eSensor Housing Material\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eSensor connection housing: AlSi10Mg, coated; 1.4408 (CF3M)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eTransmitter Housing Material\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eAlSi10Mg, coated; 1.4404 (316L)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eDegree Of Protection\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eCompact version: IP66\/67, type 4X enclosure \u003cbr\u003eSensor remote version: IP66\/67, type 4X enclosure \u003cbr\u003eTransmitter remote version: IP66\/67, type 4X enclosure\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eDisplay\/Operation\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e4‐line backlit display with touch control (operation from outside) \u003cbr\u003eConfiguration via local display and operating tools possible \u003cbr\u003eRemote display available\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eOutputs\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e4‐20 mA HART (passive) \u003cbr\u003e4‐20 mA (passive) \u003cbr\u003ePulse\/frequency\/switch output (passive)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eInputs\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e4‐20 mA (passive)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eDigital Communication\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eHART, PROFIBUS PA, FOUNDATION Fieldbus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003ePower Supply\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eDC 12 to 35 V (4‐20 mA HART with\/without pulse\/frequency\/switch output) \u003cbr\u003eDC 12 to 30 V (4‐20 mA HART, 4‐20 mA) \u003cbr\u003eDC 12 to 35 V (4‐20 mA HART, pulse\/frequency\/switch output, 4‐20 mA input) \u003cbr\u003eDC 9 to 32 V (PROFIBUS PA, pulse\/frequency\/switch output)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eHazardous Area Approvals\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eATEX, IECEx, cCSAus, JPN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eProduct Safety\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eCE, C-TICK, EAC, UK Ex\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eFunctional Safety\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eFunctional safety according to IEC 61508, applicable in safety-relevant applications in accordance with IEC 61511\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eMetrological Approvals And Certificates\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eCalibration performed on accredited calibration facilities (acc. to ISO\/IEC 17025) \u003cbr\u003eHeartbeat Technology complies with the requirements for measurement traceability according to ISO 9001:2015 – Section 7.1.5.2 a \u003cbr\u003e(TÜV SÜD attestation)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eMarine aApprovals And Certificates\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eABS, LR, BV, DNV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003ePressure Approvals And Certificates\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003ePED, CRN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eMaterial Certificates\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e3.1 material \u003cbr\u003eNACE MR0175\/MR0103, PMI (on request); only Class 900\/1500: welding test acc. to ISO 15614‐1, similar to ASME IX (on request)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/figure\u003e\u003cp\u003e \u003c\/p\u003e","brand":"Endress+Hauser","offers":[{"title":"Default Title","offer_id":48020369047769,"sku":null,"price":3062.5,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0016\/5327\/6707\/files\/Endress_Hauser_7O2C_Proline_Prowirl_O_200_Vortex_Flowmeter.png?v=1771970621"},{"product_id":"endress-hauser-7r2c-proline-prowirl-r200-vortex-flowmeter","title":"Endress+Hauser 7R2C Proline Prowirl R200 Vortex Flowmeter","description":"\u003ch1\u003eoverview\u003c\/h1\u003e\u003cp\u003eEndress+Hauser 7R2C Proline Prowirl R200 Vortex Flowmeter with best-in-class accuracy despite pipe reduction.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eSpecs at a glance\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e* Max. measurement error \u003cbr\u003eVolume flow (liquid): ±0.75 % \u003cbr\u003eVolume flow (steam, gas): ±1.00 % \u003cbr\u003eMass flow (saturated steam): ±1.7% (temperature compensated); ±1.5% (temperature\/pressure compensated) \u003cbr\u003eMass flow (superheated steam, gas): ±1.5 (temperature\/pressure compensated); ±1.7% (temperature compensated + external pressure \u003cbr\u003ecompensation) \u003cbr\u003eMass flow (liquid): ±0.85% \u003cbr\u003e* Measuring range \u003cbr\u003eLiquid: 0.1 to 540 m³\/h (0.061 to 320 ft³\/min) \u003cbr\u003edepending on medium: water with 1 bar a, 20 °C (14.5 psi a, 68° F) \u003cbr\u003eSteam, gas: 0.52 to 7300 m³\/h (0.31 to 4300 ft³\/min) \u003cbr\u003edepending on medium: steam with 180 °C, 10 bar a (356 °F, 145 psi a); air with 25 °C, 4.4 bar a (77 °F, 63.8 psi a) \u003cbr\u003e* Medium temperature range \u003cbr\u003eStandard: –40 to +260 °C (–40 to +500 °F) \u003cbr\u003eHigh\/low temperature (option): –200 to +400 °C (–328 to +752 °F) \u003cbr\u003eHigh\/low temperature (on request): –200 to +450 °C (–328 to +842 °F) \u003cbr\u003e* Max. process pressure \u003cbr\u003ePN 40, Class 300, 20K \u003cbr\u003e* Wetted materials \u003cbr\u003eMeasuring tube: 1.4408 (CF3M) \u003cbr\u003eDSC sensor: 1.4404\/F316\/F316L \u003cbr\u003eProcess connection: 1.4404\/F316\/F316L\u003c\/p\u003e\u003ch1\u003eField of application\u003c\/h1\u003e\u003cp\u003eProwirl R was designed for low flows and is thus the particularly dependable solution for energy management. Additionally its calibration option PremiumCal guarantees excellent measuring accuracy for maximum plant availability. With genuine loop-powered technology, Prowirl R 200 enables cost-effective and seamless integration into existing infrastructures. It offers highest operational safety in hazardous areas. Heartbeat Technology enables process safety at all times.\u003cbr\u003e* Preferred measuring principle for wet\/saturated\/superheated steam, gases \u0026amp; liquids (also cryogenic)\u003cbr\u003e* Dedicated to applications with very low or reduced flow Device properties\u003cbr\u003e* Integrated diameter reduction by 1 or 2 line sizes\u003cbr\u003e* Nominal diameter (mating pipe) up to DN 250 (10\")\u003cbr\u003e* Flexible positioning of pressure cell\u003cbr\u003e* Display module with data transfer function\u003cbr\u003e* Robust dual-compartment housing\u003cbr\u003e* Plant safety: worldwide approvals (SIL, Haz. area)\u003c\/p\u003e\u003ch1\u003eBenefits\u003c\/h1\u003e\u003cp\u003e * Easy energy management – integrated temperature and pressure measurement for steam and gases\u003cbr\u003e* Cost and time savings – no pipework modifications needed for line size reduction\u003cbr\u003e* Same accuracy down to Re 10 000 – most linear Vortex meter body\u003cbr\u003e* Long-term stability – robust drift-free capacitive sensor\u003cbr\u003e* Convenient device wiring – separate connection compartment, various Ethernet options\u003cbr\u003e* Safe operation – no need to open the device\u003cbr\u003e* Integrated verification – Heartbeat Technology\u003c\/p\u003e\u003ch1\u003eSpecification\u003c\/h1\u003e\u003cfigure class=\"table\"\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eitem\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003evalue\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eWarranty\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e1 Year\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eCustomized support\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eOEM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003ePlace of Origin\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eGermany\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eBrand Name\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eEndress+Hauser\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eModel Number\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eProwirl R200\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eType\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eVortex Flowmeter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eProduct Headline\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eFlowmeter with best-in-class accuracy despite pipe reduction. \u003cbr\u003eEasy energy management – integrated temperature and pressure measurement for steam and gases. \u003cbr\u003eDedicated to applications with very low flow or reduced flow.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eSensor Features\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eCost and time savings – no pipework modifications needed for line size reduction. Same accuracy down to Re 10 000 – most linear \u003cbr\u003eVortex meter body. Long-term stability – robust drift-free capacitive sensor. Integrated diameter reduction by 1 or 2 line sizes. \u003cbr\u003eNominal diameter (mating pipe) up to DN 250 (10\").\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eTransmitter Features\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eCost and time savings – no pipework modifications needed for line size reduction. Same accuracy down to Re 10 000 – most linear \u003cbr\u003eVortex meter body. Long-term stability – robust drift-free capacitive sensor. \u003cbr\u003eIntegrated diameter reduction by 1 or 2 line sizes. Nominal diameter (mating pipe) up to DN 250 (10\"). Flexible positioning of \u003cbr\u003epressure cell.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eNominal Diameter Range\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eDN 25 to 250 (1 to 10\")\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eWetted Materials\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eMeasuring tube: 1.4408 (CF3M) \u003cbr\u003eDSC sensor: 1.4404\/F316\/F316L \u003cbr\u003eProcess connection: 1.4404\/F316\/F316L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eMeasured Variables\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eVolume flow, mass flow, corrected volume flow, energy flow, heat flow difference, temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eMax. Measurement Error\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eVolume flow (liquid): ±0.75 % \u003cbr\u003eVolume flow (steam, gas): ±1.00 % \u003cbr\u003eMass flow (saturated steam): ±1.7% (temperature compensated); ±1.5% (temperature\/pressure compensated) \u003cbr\u003eMass flow (superheated steam, gas): ±1.5 (temperature\/pressure compensated); ±1.7% (temperature compensated + external pressure \u003cbr\u003ecompensation) \u003cbr\u003eMass flow (liquid): ±0.85%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eMeasuring Range\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eLiquid: 0.1 to 540 m³\/h (0.061 to 320 ft³\/min) \u003cbr\u003edepending on medium: water with 1 bar a, 20 °C (14.5 psi a, 68° F) \u003cbr\u003eSteam, gas: 0.52 to 7300 m³\/h (0.31 to 4300 ft³\/min) \u003cbr\u003edepending on medium: steam with 180 °C, 10 bar a (356 °F, 145 psi a); air with 25 °C, 4.4 bar a (77 °F, 63.8 psi a)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eMax. Process Ppressure\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003ePN 40, Class 300, 20K\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eMedium Temperature Range\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eStandard: –40 to +260 °C (–40 to +500 °F) \u003cbr\u003eHigh\/low temperature (option): –200 to +400 °C (–328 to +752 °F) \u003cbr\u003eHigh\/low temperature (on request): –200 to +450 °C (–328 to +842 °F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eAmbient Temperature Range\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eCompact version (standard): –40 to +80 °C (–40 to +176 °F) \u003cbr\u003eCompact version (option): –50 to +80 °C (–58 to +176 °F) \u003cbr\u003eRemote version (standard): –40 to +85 °C (–40 to +185 °F) \u003cbr\u003eRemote version (option): –50 to +85 °C (–58 to +185 °F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eSensor Housing Material\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eSensor connection housing: AlSi10Mg, coated; 1.4408 (CF3M)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eTransmitter Housing Material\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eAlSi10Mg, coated; 1.4404 (316L)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eDegree Of Protection\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eCompact version: IP66\/67, type 4X enclosure \u003cbr\u003eSensor remote version: IP66\/67, type 4X enclosure \u003cbr\u003eTransmitter remote version: IP66\/67, type 4X enclosure\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eDisplay\/Operation\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e4‐line backlit display with touch control (operation from outside) \u003cbr\u003eConfiguration via local display and operating tools possible \u003cbr\u003eRemote display available\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eOutputs\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e4‐20 mA HART (passive) \u003cbr\u003e4‐20 mA (passive) \u003cbr\u003ePulse\/frequency\/switch output (passive)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eInputs\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e4‐20 mA (passive)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eDigital Communication\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eHART, PROFIBUS PA, FOUNDATION Fieldbus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003ePower Supply\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eDC 12 to 35 V (4‐20 mA HART with\/without pulse\/frequency\/switch output) \u003cbr\u003eDC 12 to 30 V (4‐20 mA HART, 4‐20 mA) \u003cbr\u003eDC 12 to 35 V (4‐20 mA HART, pulse\/frequency\/switch output, 4‐20 mA input) \u003cbr\u003eDC 9 to 32 V (PROFIBUS PA, pulse\/frequency\/switch output)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eHazardous Area Approvals\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eATEX, IECEx, cCSAus, JPN, EAC, UK Ex\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eProduct Safety\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eCE, C-tick, EAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eFunctional Safety\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eFunctional safety according to IEC 61508, applicable in safety-relevant applications in accordance with IEC 61511\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eMetrological Approvals And Certificates\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eCalibration performed on accredited calibration facilities (acc. to ISO\/IEC 17025) \u003cbr\u003eHeartbeat Technology complies with the requirements for measurement traceability according to ISO 9001:2015 – Section 7.1.5.2 a \u003cbr\u003e(TÜV SÜD attestation)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eMarine aApprovals And Certificates\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eABS, LR, BV, DNV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003ePressure Approvals And Certificates\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003ePED, CRN, AD 2000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eMaterial Certificates\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e3.1 material \u003cbr\u003eNACE MR0175\/MR0103, PMI (on request); welding test acc. to ISO 15614‐1, similar to ASME IX (on request)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/figure\u003e\u003cp\u003e \u003c\/p\u003e","brand":"Endress+Hauser","offers":[{"title":"Default Title","offer_id":48020369178841,"sku":null,"price":3375.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0016\/5327\/6707\/files\/Endress_Hauser_7R2C_Proline_Prowirl_R_200_Vortex_Flowmeter.png?v=1771970623"}],"url":"https:\/\/www.aloinfousa.com\/ja\/collections\/endress-hauser-prowirl.oembed","provider":"aloinfousa.com","version":"1.0","type":"link"}