{"product_id":"juniper-acx500-dc-router-i7mcn","title":"Juniper ACX500-DC Router","description":"\u003cdiv class=\"short-hide\"\u003e[shortdesc]\n\u003cul\u003e\n\n\u003cli\u003eACX500 Indoor Unit\u003c\/li\u003e\n\u003cli\u003e2 x 1GE (SFP)\u003c\/li\u003e\n\u003cli\u003e4 x 1GE (Combo)\u003c\/li\u003e\n\u003cli\u003ewith single DC power supply\u003c\/li\u003e\n\u003cli\u003e1 RU\u003c\/li\u003e\n\u003cli\u003eTemperature hardened\u003c\/li\u003e\n\u003cli\u003ePassive Cooling\u003c\/li\u003e\n\u003cli\u003eRack mounting options (mounting kits sold separately)\u003c\/li\u003e\n\u003cli\u003ePoE support\u003c\/li\u003e\n\u003cli\u003eJunos\u003c\/li\u003e\n\u003c\/ul\u003e\n[\/shortdesc]\u003c\/div\u003e\n\u003cp class=\"p1\"\u003e[properties]\u003cmeta charset=\"utf-8\"\u003e\u003c\/p\u003e\n\u003cstyle type=\"text\/css\"\u003e\u003c!--\ntd {border: 1px solid #cccccc;}br {mso-data-placement:same-cell;}\n--\u003e\u003c\/style\u003e\n\u003ctable border=\"1\" dir=\"ltr\" cellpadding=\"0\" cellspacing=\"0\" xmlns=\"http:\/\/www.w3.org\/1999\/xhtml\"\u003e\n\u003ccolgroup\u003e\n\u003ccol width=\"222\"\u003e\n\u003ccol width=\"364\"\u003e\n\u003c\/colgroup\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd data-sheets-numberformat='{\"1\":1}' data-sheets-value='{\"1\":2,\"2\":\"Properties\"}'\u003eProperties\u003c\/td\u003e\n\u003ctd data-sheets-numberformat='{\"1\":1}' data-sheets-value='{\"1\":2,\"2\":\"Juniper ACX500-DC\"}'\u003eJuniper ACX500-DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-sheets-numberformat='{\"1\":1}' data-sheets-value='{\"1\":2,\"2\":\"Description\"}'\u003eDescription\u003c\/td\u003e\n\u003ctd data-sheets-numberformat='{\"1\":1}' data-sheets-value='{\"1\":2,\"2\":\"ACX500 indoor unit 2x1GbE (SFP) + 4x1GbE (combo) with single DC power supply, 1 U, temperature hardened, passive cooling, rack mounting options, PoE support, Junos OS\"}'\u003eACX500 indoor unit 2x1GbE (SFP) + 4x1GbE (combo) with single DC power supply, 1 U, temperature hardened, passive cooling, rack mounting options, PoE support, Junos OS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-sheets-numberformat='{\"1\":1}' data-sheets-value='{\"1\":2,\"2\":\"Product Family\"}'\u003eProduct Family\u003c\/td\u003e\n\u003ctd data-sheets-numberformat='{\"1\":1}' data-sheets-value='{\"1\":2,\"2\":\"ACX500 Series\"}'\u003eACX500 Series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-sheets-numberformat='{\"1\":1}' data-sheets-value='{\"1\":2,\"2\":\"Product Type\"}'\u003eProduct Type\u003c\/td\u003e\n\u003ctd data-sheets-numberformat='{\"1\":1}' data-sheets-value='{\"1\":2,\"2\":\"Router\"}'\u003eRouter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-sheets-numberformat='{\"1\":1}' data-sheets-value='{\"1\":2,\"2\":\"Built-In Interface Options\"}' colspan=\"2\" rowspan=\"1\"\u003eBuilt-In Interface Options\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-sheets-numberformat='{\"1\":1}' data-sheets-value='{\"1\":2,\"2\":\"GbE (combo)\"}'\u003eGbE (combo)\u003c\/td\u003e\n\u003ctd data-sheets-numberformat='{\"1\":1}' data-sheets-value='{\"1\":2,\"2\":\"4 (PoE+ support on 3 ports)\"}'\u003e4 (PoE+ support on 3 ports)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-sheets-numberformat='{\"1\":1}' data-sheets-value='{\"1\":2,\"2\":\"GbE (SFP)\"}'\u003eGbE (SFP)\u003c\/td\u003e\n\u003ctd data-sheets-numberformat='{\"1\":1}' data-sheets-value='{\"1\":2,\"2\":\"2\"}'\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-sheets-numberformat='{\"1\":1}' data-sheets-value='{\"1\":2,\"2\":\"Console port\"}'\u003eConsole port\u003c\/td\u003e\n\u003ctd data-sheets-numberformat='{\"1\":1}' data-sheets-value='{\"1\":2,\"2\":\"RJ-45 connector\"}'\u003eRJ-45 connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-sheets-numberformat='{\"1\":1}' data-sheets-value='{\"1\":2,\"2\":\"Management Ethernet port\"}'\u003eManagement Ethernet port\u003c\/td\u003e\n\u003ctd data-sheets-numberformat='{\"1\":1}' data-sheets-value='{\"1\":2,\"2\":\"RJ-45 connector\"}'\u003eRJ-45 connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-sheets-numberformat='{\"1\":1}' data-sheets-value='{\"1\":2,\"2\":\"Dimension (WxHxD)\"}'\u003eDimension (WxHxD)\u003c\/td\u003e\n\u003ctd data-sheets-numberformat='{\"1\":1}' data-sheets-value='{\"1\":2,\"2\":\"17.5 x 1.75 x 9.4 in (44.5 x 4.4 x 24 cm)\"}'\u003e17.5 x 1.75 x 9.4 in (44.5 x 4.4 x 24 cm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-sheets-numberformat='{\"1\":1}' data-sheets-value='{\"1\":2,\"2\":\"Weight (lb\/kg) fully configured\"}'\u003eWeight (lb\/kg) fully configured\u003c\/td\u003e\n\u003ctd data-sheets-numberformat='{\"1\":1}' data-sheets-value='{\"1\":2,\"2\":\"8.6 lb (3.9 kg)\"}'\u003e8.6 lb (3.9 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-sheets-numberformat='{\"1\":1}' data-sheets-value='{\"1\":2,\"2\":\"Power\"}'\u003ePower\u003c\/td\u003e\n\u003ctd data-sheets-numberformat='{\"1\":1}' data-sheets-value='{\"1\":2,\"2\":\"-48 V nominal or -60 V telco nominal or +24 VDC nominal\"}'\u003e-48 V nominal or -60 V telco nominal or +24 VDC nominal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-sheets-numberformat='{\"1\":1}' data-sheets-value='{\"1\":2,\"2\":\"Maximum power draw\"}'\u003eMaximum power draw\u003c\/td\u003e\n\u003ctd data-sheets-numberformat='{\"1\":1}' data-sheets-value='{\"1\":2,\"2\":\"65 W + PoE power (80 W)\"}'\u003e65 W + PoE power (80 W)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-sheets-numberformat='{\"1\":1}' data-sheets-value='{\"1\":2,\"2\":\"Rack Unit\"}'\u003eRack Unit\u003c\/td\u003e\n\u003ctd data-sheets-numberformat='{\"1\":1}' data-sheets-value='{\"1\":2,\"2\":\"1 U\"}'\u003e1 U\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp class=\"p1\"\u003e[\/properties][specifications]\u003cmeta charset=\"utf-8\"\u003e\u003c\/p\u003e\n\u003cstyle type=\"text\/css\"\u003e\u003c!--\ntd {border: 1px solid #cccccc;}br {mso-data-placement:same-cell;}\n--\u003e\u003c\/style\u003e\n\u003ctable border=\"1\" dir=\"ltr\" cellpadding=\"0\" cellspacing=\"0\" xmlns=\"http:\/\/www.w3.org\/1999\/xhtml\"\u003e\n\u003ccolgroup\u003e\n\u003ccol width=\"383\"\u003e\n\u003ccol width=\"393\"\u003e\n\u003c\/colgroup\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd data-sheets-numberformat='{\"1\":1}' data-sheets-value='{\"1\":2,\"2\":\"Specifications\"}'\u003eSpecifications\u003c\/td\u003e\n\u003ctd data-sheets-numberformat='{\"1\":1}' data-sheets-value='{\"1\":2,\"2\":\"ACX500-DC\"}'\u003eACX500-DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-sheets-numberformat='{\"1\":1}' data-sheets-value='{\"1\":2,\"2\":\"System Throughput\"}'\u003eSystem Throughput\u003c\/td\u003e\n\u003ctd data-sheets-numberformat='{\"1\":1}' data-sheets-value='{\"1\":2,\"2\":\"Up to 60 Gbps\"}'\u003eUp to 60 Gbps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-sheets-numberformat='{\"1\":1}' data-sheets-value='{\"1\":2,\"2\":\"Operating temperature\"}'\u003eOperating temperature\u003c\/td\u003e\n\u003ctd data-sheets-numberformat='{\"1\":1}' data-sheets-value='{\"1\":2,\"2\":\"-40° to 149° F (-40° to 65° C)\"}'\u003e-40° to 149° F (-40° to 65° C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-sheets-numberformat='{\"1\":1}' data-sheets-value='{\"1\":2,\"2\":\"Humidity\"}'\u003eHumidity\u003c\/td\u003e\n\u003ctd data-sheets-numberformat='{\"1\":1}' data-sheets-value='{\"1\":2,\"2\":\"95% RH noncondensing\"}'\u003e95% RH noncondensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-sheets-numberformat='{\"1\":1}' data-sheets-value='{\"1\":2,\"2\":\"Platform Features\"}' colspan=\"2\" rowspan=\"1\"\u003ePlatform Features\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-sheets-numberformat='{\"1\":1}' data-sheets-value='{\"1\":2,\"2\":\"Layer 2\"}'\u003eLayer 2\u003c\/td\u003e\n\u003ctd data-sheets-numberformat='{\"1\":1}' data-sheets-value='{\"1\":2,\"2\":\"IEEE 802.3 bridging\\nIEEE 802.1q\\nIEEE 802.1ad (Q-in-Q)\\nVLAN id manipulation for outer\/inner: swap\/pop\/push\\nRapid Spanning Tree Protocol (RSTP)\/VLAN Spanning Tree Protocol (VSTP)\/Multiple Spanning Tree Protocol (MSTP)\\nLink Aggregation Control Protocol (LACP)\\nEnhanced load balancing based on L2-L4 header info\\nLink Layer Discovery Protocol (LLDP)\\nLayer 2 bridge protocol data unit (BPDU) tunneling\/MAC rewrite\"}'\u003eIEEE 802.3 bridging\u003cbr\u003eIEEE 802.1q\u003cbr\u003eIEEE 802.1ad (Q-in-Q)\u003cbr\u003eVLAN id manipulation for outer\/inner: swap\/pop\/push\u003cbr\u003eRapid Spanning Tree Protocol (RSTP)\/VLAN Spanning Tree Protocol (VSTP)\/Multiple Spanning Tree Protocol (MSTP)\u003cbr\u003eLink Aggregation Control Protocol (LACP)\u003cbr\u003eEnhanced load balancing based on L2-L4 header info\u003cbr\u003eLink Layer Discovery Protocol (LLDP)\u003cbr\u003eLayer 2 bridge protocol data unit (BPDU) tunneling\/MAC rewrite\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-sheets-numberformat='{\"1\":1}' data-sheets-value='{\"1\":2,\"2\":\"Layer 3\"}'\u003eLayer 3\u003c\/td\u003e\n\u003ctd data-sheets-numberformat='{\"1\":1}' data-sheets-value='{\"1\":2,\"2\":\"IPv4\\nIPv6\\nRPF\\nEqual-cost multipath (ECMP)\\nEnhanced load balancing based on L2-L4 header info\\nOSPF\\nIS-IS\\nBGP\\nIndirect\/composite next hop\"}'\u003eIPv4\u003cbr\u003eIPv6\u003cbr\u003eRPF\u003cbr\u003eEqual-cost multipath (ECMP)\u003cbr\u003eEnhanced load balancing based on L2-L4 header info\u003cbr\u003eOSPF\u003cbr\u003eIS-IS\u003cbr\u003eBGP\u003cbr\u003eIndirect\/composite next hop\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-sheets-numberformat='{\"1\":1}' data-sheets-value='{\"1\":2,\"2\":\"MPLS and Seamless MPLS\"}'\u003eMPLS and Seamless MPLS\u003c\/td\u003e\n\u003ctd data-sheets-numberformat='{\"1\":1}' data-sheets-value='{\"1\":2,\"2\":\"RSVP\\nLDP\\nPath Computation Element Protocol (PCEP)\\nRSVP-TE\\nBGP-LU \\nLDP-RSVP\\nRSVP fast reroute (FRR)\"}'\u003eRSVP\u003cbr\u003eLDP\u003cbr\u003ePath Computation Element Protocol (PCEP)\u003cbr\u003eRSVP-TE\u003cbr\u003eBGP-LU \u003cbr\u003eLDP-RSVP\u003cbr\u003eRSVP fast reroute (FRR)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-sheets-numberformat='{\"1\":1}' data-sheets-value='{\"1\":2,\"2\":\"Services\"}'\u003eServices\u003c\/td\u003e\n\u003ctd data-sheets-numberformat='{\"1\":1}' data-sheets-value='{\"1\":2,\"2\":\"IEEE 802.3 bridge domain\\nPWE (T-LDP)\\nL2VPN (BGP)\\nLayer 3 VPN\\nIntegrated routing and bridging (IRB)\\nStateless filters L2-L4\"}'\u003eIEEE 802.3 bridge domain\u003cbr\u003ePWE (T-LDP)\u003cbr\u003eL2VPN (BGP)\u003cbr\u003eLayer 3 VPN\u003cbr\u003eIntegrated routing and bridging (IRB)\u003cbr\u003eStateless filters L2-L4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-sheets-numberformat='{\"1\":1}' data-sheets-value='{\"1\":2,\"2\":\"Class of Service (CoS)\"}'\u003eClass of Service (CoS)\u003c\/td\u003e\n\u003ctd data-sheets-numberformat='{\"1\":1}' data-sheets-value='{\"1\":2,\"2\":\"8 queues per port with schedulers and shaping\\nClassification based on 802.1p, DiffServ code point(DSCP), IP-precedence, Exp bit\\nSingle-rate policer ingress\/egress\\nTwo-rate three-color policer ingress\/egress\\nPer-Port Egress Shaping\"}'\u003e8 queues per port with schedulers and shaping\u003cbr\u003eClassification based on 802.1p, DiffServ code point(DSCP), IP-precedence, Exp bit\u003cbr\u003eSingle-rate policer ingress\/egress\u003cbr\u003eTwo-rate three-color policer ingress\/egress\u003cbr\u003ePer-Port Egress Shaping\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-sheets-numberformat='{\"1\":1}' data-sheets-value='{\"1\":2,\"2\":\"OAM and SLA Management\"}'\u003eOAM and SLA Management\u003c\/td\u003e\n\u003ctd data-sheets-numberformat='{\"1\":1}' data-sheets-value='{\"1\":2,\"2\":\"Bidirectional Forwarding Detection (BFD)\\nConnectivity fault management (CFM)\\nY.1731\\nRFC2544\\nTWAMP\"}'\u003eBidirectional Forwarding Detection (BFD)\u003cbr\u003eConnectivity fault management (CFM)\u003cbr\u003eY.1731\u003cbr\u003eRFC2544\u003cbr\u003eTWAMP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-sheets-numberformat='{\"1\":1}' data-sheets-value='{\"1\":2,\"2\":\"Multicast\"}'\u003eMulticast\u003c\/td\u003e\n\u003ctd data-sheets-numberformat='{\"1\":1}' data-sheets-value='{\"1\":2,\"2\":\"Protocol Independent Multicast (PIM)\\nInternet Group Management Protocol (IGMP)\\nIGMP snooping\"}'\u003eProtocol Independent Multicast (PIM)\u003cbr\u003eInternet Group Management Protocol (IGMP)\u003cbr\u003eIGMP snooping\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-sheets-numberformat='{\"1\":1}' data-sheets-value='{\"1\":2,\"2\":\"Timing and Sync\"}'\u003eTiming and Sync\u003c\/td\u003e\n\u003ctd data-sheets-numberformat='{\"1\":1}' data-sheets-value='{\"1\":2,\"2\":\"BITS\/1pps\/10MHz\\n1588v2 BC\\n1588v2 over IP\\n1588v2 over Ethernet\\nSynchronous Ethernet\\nHybrid mode\\nEmbedded GM\"}'\u003eBITS\/1pps\/10MHz\u003cbr\u003e1588v2 BC\u003cbr\u003e1588v2 over IP\u003cbr\u003e1588v2 over Ethernet\u003cbr\u003eSynchronous Ethernet\u003cbr\u003eHybrid mode\u003cbr\u003eEmbedded GM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-sheets-numberformat='{\"1\":1}' data-sheets-value='{\"1\":2,\"2\":\"Security\"}'\u003eSecurity\u003c\/td\u003e\n\u003ctd data-sheets-numberformat='{\"1\":1}' data-sheets-value='{\"1\":2,\"2\":\"L2 storm control\\nIPsec    \\nNAT\"}'\u003eL2 storm control\u003cbr\u003eIPsec \u003cbr\u003eNAT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-sheets-numberformat='{\"1\":1}' data-sheets-value='{\"1\":2,\"2\":\"Configuration, Management and Automation\"}'\u003eConfiguration, Management and Automation\u003c\/td\u003e\n\u003ctd data-sheets-numberformat='{\"1\":1}' data-sheets-value='{\"1\":2,\"2\":\"CLI\\nNETCONF\\nNMP v2\/v3\\nSLAX\/Python on-box scripting tools\\nZTD\\nYANG\"}'\u003eCLI\u003cbr\u003eNETCONF\u003cbr\u003eNMP v2\/v3\u003cbr\u003eSLAX\/Python on-box scripting tools\u003cbr\u003eZTD\u003cbr\u003eYANG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-sheets-numberformat='{\"1\":1}' data-sheets-value='{\"1\":2,\"2\":\"Safety Approvals\"}'\u003eSafety Approvals\u003c\/td\u003e\n\u003ctd data-sheets-numberformat='{\"1\":1}' data-sheets-value='{\"1\":2,\"2\":\"CAN\/CSA-C22.2 No. 60950-1\\nUL 60950-1\\nEN 60950-1\\nIEC 60950-1CB Scheme\\nEN 60825-1\"}'\u003eCAN\/CSA-C22.2 No. 60950-1\u003cbr\u003eUL 60950-1\u003cbr\u003eEN 60950-1\u003cbr\u003eIEC 60950-1CB Scheme\u003cbr\u003eEN 60825-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-sheets-numberformat='{\"1\":1}' data-sheets-value='{\"1\":2,\"2\":\"EMC\"}'\u003eEMC\u003c\/td\u003e\n\u003ctd data-sheets-numberformat='{\"1\":1}' data-sheets-value='{\"1\":2,\"2\":\"AS\/NZS CISPR22 Class A\\nEN55022 Class A\\nVCCI Class A\\nFCC Part 15 Class A\\nIECS-003 Issue 4\\nBSMI CNS 13438 and NCC C6357 Taiwan Radiated Emissions\\nKN 22, Class A\\nCISPR 32\/EN55032: 2012 European Radiated Emissions Class A\\nEN-61000-4-6 Low Frequency Common Immunity\\nEN-61000-4-11 Voltage Dips and Sags\\nCISPR 24\/EN55024 Information Technology Equipment Immunity Characteristics\"}'\u003eAS\/NZS CISPR22 Class A\u003cbr\u003eEN55022 Class A\u003cbr\u003eVCCI Class A\u003cbr\u003eFCC Part 15 Class A\u003cbr\u003eIECS-003 Issue 4\u003cbr\u003eBSMI CNS 13438 and NCC C6357 Taiwan Radiated Emissions\u003cbr\u003eKN 22, Class A\u003cbr\u003eCISPR 32\/EN55032: 2012 European Radiated Emissions Class A\u003cbr\u003eEN-61000-4-6 Low Frequency Common Immunity\u003cbr\u003eEN-61000-4-11 Voltage Dips and Sags\u003cbr\u003eCISPR 24\/EN55024 Information Technology Equipment Immunity Characteristics\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-sheets-numberformat='{\"1\":1}' data-sheets-value='{\"1\":2,\"2\":\"ETSI (European Telecommunications Standardization Institute)\"}'\u003eETSI (European Telecommunications Standardization Institute)\u003c\/td\u003e\n\u003ctd data-sheets-numberformat='{\"1\":1}' data-sheets-value='{\"1\":2,\"2\":\"EN 300 386 V1.6.1 Telecommunication Network Equipment, Electromagnetic Compatibility Requirements\\nETSI EN 300 019-2-1 (2000) Storage, Class T1.2\\nETSI EN 300 019-2-2 (1999) Transportation, Class T2.3\\nETSI EN 300 019-2-3 (2003) Stationary Use at Weather Protected Locations, Class T3.2\\nETSI 300753 (1997) Acoustic Noise Emitted by Telecommunications Equipment\"}'\u003eEN 300 386 V1.6.1 Telecommunication Network Equipment, Electromagnetic Compatibility Requirements\u003cbr\u003eETSI EN 300 019-2-1 (2000) Storage, Class T1.2\u003cbr\u003eETSI EN 300 019-2-2 (1999) Transportation, Class T2.3\u003cbr\u003eETSI EN 300 019-2-3 (2003) Stationary Use at Weather Protected Locations, Class T3.2\u003cbr\u003eETSI 300753 (1997) Acoustic Noise Emitted by Telecommunications Equipment\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-sheets-numberformat='{\"1\":1}' data-sheets-value='{\"1\":2,\"2\":\"Other EMC Requirements\"}'\u003eOther EMC Requirements\u003c\/td\u003e\n\u003ctd data-sheets-numberformat='{\"1\":1}' data-sheets-value='{\"1\":2,\"2\":\"IEEE 1613 Class 2 Environmental and Testing Requirements for Communications Networking\\nDevices in Electric Power Substations\\nIEC 61850-3 Communication networks and systems for power utility automation\\nEN50121-4 Railway applications\\nETSI EN 300 440-1\/-2 GPS spurious emission\\nDeutsche Telekom 1TR9 (2008) EMC Specification\\nBritish Telecom EMC Immunity Requirements (2007)\\nITU-T K.21 (2011) Resistibility of telecommunication equipment installed in customer premises to overvoltages and overcurrents\\nITU-T K.20 (2011) Resistibility of telecommunication equipment installed in telecom centers to overvoltages and overcurrents\"}'\u003eIEEE 1613 Class 2 Environmental and Testing Requirements for Communications Networking\u003cbr\u003eDevices in Electric Power Substations\u003cbr\u003eIEC 61850-3 Communication networks and systems for power utility automation\u003cbr\u003eEN50121-4 Railway applications\u003cbr\u003eETSI EN 300 440-1\/-2 GPS spurious emission\u003cbr\u003eDeutsche Telekom 1TR9 (2008) EMC Specification\u003cbr\u003eBritish Telecom EMC Immunity Requirements (2007)\u003cbr\u003eITU-T K.21 (2011) Resistibility of telecommunication equipment installed in customer premises to overvoltages and overcurrents\u003cbr\u003eITU-T K.20 (2011) Resistibility of telecommunication equipment installed in telecom centers to overvoltages and overcurrents\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-sheets-numberformat='{\"1\":1}' data-sheets-value='{\"1\":2,\"2\":\"NEBS\"}'\u003eNEBS\u003c\/td\u003e\n\u003ctd data-sheets-numberformat='{\"1\":1}' data-sheets-value='{\"1\":2,\"2\":\"SR-3580 NEBS Criteria Levels (Level 3 Compliance)\\nGR-63-CORE: NEBS, Physical Protection\\nGR-1089-CORE: EMC and Electrical Safety for Network Telecommunications Equipment (Issue 6 compliant)\\nGR-3108-CORE: Generic Requirements for Network Equipment in the Outside Plant (OSP)\"}'\u003eSR-3580 NEBS Criteria Levels (Level 3 Compliance)\u003cbr\u003eGR-63-CORE: NEBS, Physical Protection\u003cbr\u003eGR-1089-CORE: EMC and Electrical Safety for Network Telecommunications Equipment (Issue 6 compliant)\u003cbr\u003eGR-3108-CORE: Generic Requirements for Network Equipment in the Outside Plant (OSP)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-sheets-numberformat='{\"1\":1}' data-sheets-value='{\"1\":2,\"2\":\"Telecomm Compliance\"}'\u003eTelecomm Compliance\u003c\/td\u003e\n\u003ctd data-sheets-numberformat='{\"1\":1}' data-sheets-value='{\"1\":2,\"2\":\"Device management: NETCONF, CLI, SNMP v1\/v2\/v3\\nEnd-to-end provisioning of E-Line, emulated LAN (ELAN), Layer 3 VPN (L3VPN), OAM, class of service (CoS)\\nDevice and service-level fault management\\nDevice and service-level performance management\"}'\u003eDevice management: NETCONF, CLI, SNMP v1\/v2\/v3\u003cbr\u003eEnd-to-end provisioning of E-Line, emulated LAN (ELAN), Layer 3 VPN (L3VPN), OAM, class of service (CoS)\u003cbr\u003eDevice and service-level fault management\u003cbr\u003eDevice and service-level performance management\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-sheets-numberformat='{\"1\":1}' data-sheets-value='{\"1\":2,\"2\":\"Metro Ethernet Forum (MEF)\"}'\u003eMetro Ethernet Forum (MEF)\u003c\/td\u003e\n\u003ctd data-sheets-numberformat='{\"1\":1}' data-sheets-value='{\"1\":2,\"2\":\"MEF CE2.0 compliant\"}'\u003eMEF CE2.0 compliant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp class=\"p1\"\u003e[\/specifications][accesories]\u003cmeta charset=\"utf-8\"\u003e\u003c\/p\u003e\n\u003cstyle type=\"text\/css\"\u003e\u003c!--\ntd {border: 1px solid #cccccc;}br {mso-data-placement:same-cell;}\n--\u003e\u003c\/style\u003e\n\u003ctable border=\"1\" dir=\"ltr\" cellpadding=\"0\" cellspacing=\"0\" xmlns=\"http:\/\/www.w3.org\/1999\/xhtml\"\u003e\n\u003ccolgroup\u003e\n\u003ccol width=\"149\"\u003e\n\u003ccol width=\"271\"\u003e\n\u003c\/colgroup\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"Accessories\"}' colspan=\"2\" rowspan=\"1\"\u003eAccessories\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"PKG-1U-ACXS\"}'\u003ePKG-1U-ACXS\u003c\/td\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"Package Spare for ACX 1RU Chassis\"}'\u003ePackage Spare for ACX 1RU Chassis\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"RACK-MNT-1RU-19-S\"}'\u003eRACK-MNT-1RU-19-S\u003c\/td\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"ACX Series 1 RU 19\\\" Mounting Bracket\\\"\"}'\u003eACX Series 1 RU 19\" Mounting Bracket\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"RACK-MNT-1RU-23-S\"}'\u003eRACK-MNT-1RU-23-S\u003c\/td\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"ACX Series 1 RU 23\\\" Mounting Bracket\\\"\"}'\u003eACX Series 1 RU 23\" Mounting Bracket\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"CBL-PWR-C15M-HITEMP-US\"}'\u003eCBL-PWR-C15M-HITEMP-US\u003c\/td\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"Power Cord, AC, C15M\"}'\u003ePower Cord, AC, C15M\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"Licenses\"}' colspan=\"2\" rowspan=\"1\"\u003eLicenses\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"ACX500-LIC-GPS\"}'\u003eACX500-LIC-GPS\u003c\/td\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"ACX500 license to activate GPS receiver\"}'\u003eACX500 license to activate GPS receiver\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"ACX500-LIC-SEC\"}'\u003eACX500-LIC-SEC\u003c\/td\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"ACX500 license to activate IPsec and NAT features\"}'\u003eACX500 license to activate IPsec and NAT features\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp class=\"p1\"\u003e[\/accesories]\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eJuniper ACX500 is a small form factor, hardened fanless router that delivers up to 6 Gbps throughput. It comes with an integrated software-enabled GPS receiver and supports a rich set of security, timing, and synchronization features. Additionally, ACX500 has been certified for indoor and outdoor use for utilities and railways. It is ideal for small cell, LTE-Advanced mobile backhaul deployments, as well as use cases in the industrial environment.\u003c\/span\u003e\u003c\/p\u003e","brand":"Juniper","offers":[{"title":"Default Title","offer_id":48013240041689,"sku":"ACX500-DC-NEW","price":7219.29,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0016\/5327\/6707\/files\/ACX500_a8e9fdbb-9858-4256-a61c-fef1b5cfeffb.jpg?v=1771852499","url":"https:\/\/www.aloinfousa.com\/ja\/products\/juniper-acx500-dc-router-i7mcn","provider":"aloinfousa.com","version":"1.0","type":"link"}