{"product_id":"dell-poweredge-r540-server-5bolm","title":"Dell PowerEdge R540 Server","description":"\u003cdiv class=\"head-content-set-outer\"\u003e\n\u003ch2 class=\"Dell_PowerEdge_R630_Specifications\"\u003eour Dell PowerEdge R540 Specifications\u003c\/h2\u003e\n\u003c!-- Chassis Section Order 1 --\u003e\n\u003cdiv class=\"head-content-set\"\u003e\n\u003ch3\u003eChassis\u003c\/h3\u003e\n\u003cdiv class=\"head-content-set-content\"\u003e\n\u003cp\u003eThe Dell PowerEdge R540 server is a flexible and capable system that is great for businesses of all sizes. This 2U rackmount server has two chassis options to choose from: 8 Bay LFF and 12 Bay LFF. The PowerEdge R540 does not have a 2.5\" option. There are also a handful of rear configurations to choose from.\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003e8 Bay LFF\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003eThe 8 Bay LFF chassis for the PowerEdge R540 has support for up to eight 3.5\" hot-swap SAS\/SATA hard drives. 2.5\" HDDs or SSDs can be installed via a 2.5\" to 3.5\" drive converter.\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003e12 Bay LFF\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003eThe R540's 12 Bay LFF chassis option can accept up to twelve 3.5\" hot-swap SAS\/SATA hard drives. Just like the 8 Bay LFF chassis, 2.5\" HDDs or SSDs can be used via a 2.5\" to 3.5\" drive adapter.\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eRear Configurations\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003eThere are three different rear configurations for the PowerEdge R540. The first configuration has two low-profile PCIe slots, and two 3.5\" rear drive bays. The second configuration has one full-height PCIe slot and two 3.5\" rear drive bays. The final rear configuration has one full height and four low-profile PCIe slots with no rear drive bays. Each chassis has a System ID button, CMA power port, two Type A USB 3.0 ports, a dedicated iDRAC port, two 1GbE RJ45 LAN ports, LOM riser slot, and two hot-swap power supply bays.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c!-- Processing Power Section Order 2 --\u003e\n\u003cdiv class=\"head-content-set\"\u003e\n\u003ch3\u003eProcessing Power\u003c\/h3\u003e\n\u003cdiv class=\"head-content-set-content\"\u003e\n\u003cp\u003eThe Dell PowerEdge R540 server has two LGA-3647 CPU sockets inside that supports 1st Generation or 2nd Generation Intel Xeon Scalable processors. A max of 20 cores per processor are supported.\u003c\/p\u003e\n\u003cdiv class=\"outercontainerOfTwoTable\"\u003e\n\u003cdiv class=\"outercontainerOfOneTable\"\u003e\n\u003ch4 class=\"sub-title\"\u003e1st Generation Intel Xeon Scalable\u003c\/h4\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eCPU\u003c\/th\u003e\n\u003cth\u003eStep Code\u003c\/th\u003e\n\u003cth\u003eCores\u003c\/th\u003e\n\u003cth\u003eFrequency\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eBronze 3104\u003c\/td\u003e\n\u003ctd\u003eSR3GM\u003c\/td\u003e\n\u003ctd\u003e6\u003c\/td\u003e\n\u003ctd\u003e1.7GHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBronze 3106\u003c\/td\u003e\n\u003ctd\u003eSR3GL\u003c\/td\u003e\n\u003ctd\u003e8\u003c\/td\u003e\n\u003ctd\u003e1.7GHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSilver 4106H\u003c\/td\u003e\n\u003ctd\u003eSR44Y\u003c\/td\u003e\n\u003ctd\u003e8\u003c\/td\u003e\n\u003ctd\u003e1.8GHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSilver 4108\u003c\/td\u003e\n\u003ctd\u003eSR3GJ\u003c\/td\u003e\n\u003ctd\u003e8\u003c\/td\u003e\n\u003ctd\u003e1.8GHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSilver 4109T\u003c\/td\u003e\n\u003ctd\u003eSR3GP\u003c\/td\u003e\n\u003ctd\u003e8\u003c\/td\u003e\n\u003ctd\u003e2.0 GHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSilver 4110\u003c\/td\u003e\n\u003ctd\u003eSR3GH\u003c\/td\u003e\n\u003ctd\u003e8\u003c\/td\u003e\n\u003ctd\u003e2.1GHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSilver 4112\u003c\/td\u003e\n\u003ctd\u003eSR3GN\u003c\/td\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003ctd\u003e2.6GHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSilver 4114\u003c\/td\u003e\n\u003ctd\u003eSR3GK\u003c\/td\u003e\n\u003ctd\u003e10\u003c\/td\u003e\n\u003ctd\u003e2.2GHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSilver 4114T\u003c\/td\u003e\n\u003ctd\u003eSR3MM\u003c\/td\u003e\n\u003ctd\u003e10\u003c\/td\u003e\n\u003ctd\u003e2.2GHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSilver 4116\u003c\/td\u003e\n\u003ctd\u003eSR3HQ\u003c\/td\u003e\n\u003ctd\u003e12\u003c\/td\u003e\n\u003ctd\u003e2.1GHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSilver 4116T\u003c\/td\u003e\n\u003ctd\u003eSR3MQ\u003c\/td\u003e\n\u003ctd\u003e12\u003c\/td\u003e\n\u003ctd\u003e2.1GHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSilver 4123\u003c\/td\u003e\n\u003ctd\u003eSR3VW\u003c\/td\u003e\n\u003ctd\u003e8\u003c\/td\u003e\n\u003ctd\u003e3.0GHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGold 5115\u003c\/td\u003e\n\u003ctd\u003eSR3GB\u003c\/td\u003e\n\u003ctd\u003e10\u003c\/td\u003e\n\u003ctd\u003e2.4GHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGold 5117\u003c\/td\u003e\n\u003ctd\u003eSR37S\u003c\/td\u003e\n\u003ctd\u003e14\u003c\/td\u003e\n\u003ctd\u003e2.0GHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGold 5117F\u003c\/td\u003e\n\u003ctd\u003eSR3KM\u003c\/td\u003e\n\u003ctd\u003e14\u003c\/td\u003e\n\u003ctd\u003e2.0GHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGold 5118\u003c\/td\u003e\n\u003ctd\u003eSR3GF\u003c\/td\u003e\n\u003ctd\u003e12\u003c\/td\u003e\n\u003ctd\u003e2.4GHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGold 5119T\u003c\/td\u003e\n\u003ctd\u003eSR3MN\u003c\/td\u003e\n\u003ctd\u003e14\u003c\/td\u003e\n\u003ctd\u003e1.9GHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGold 5120\u003c\/td\u003e\n\u003ctd\u003eSR3GD\u003c\/td\u003e\n\u003ctd\u003e14\u003c\/td\u003e\n\u003ctd\u003e2.2GHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGold 5120T\u003c\/td\u003e\n\u003ctd\u003eSR3GC\u003c\/td\u003e\n\u003ctd\u003e14\u003c\/td\u003e\n\u003ctd\u003e2.2GHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGold 5122\u003c\/td\u003e\n\u003ctd\u003eSR3AT\u003c\/td\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003ctd\u003e3.6GHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGold 6122\u003c\/td\u003e\n\u003ctd\u003eSRCKF\u003c\/td\u003e\n\u003ctd\u003e20\u003c\/td\u003e\n\u003ctd\u003e1.8GHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGold 6126\u003c\/td\u003e\n\u003ctd\u003eSR3B3\u003c\/td\u003e\n\u003ctd\u003e12\u003c\/td\u003e\n\u003ctd\u003e2.6GHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGold 6126F\u003c\/td\u003e\n\u003ctd\u003eSR3KE\u003c\/td\u003e\n\u003ctd\u003e12\u003c\/td\u003e\n\u003ctd\u003e2.6GHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGold 6126T\u003c\/td\u003e\n\u003ctd\u003eSR3J9\u003c\/td\u003e\n\u003ctd\u003e12\u003c\/td\u003e\n\u003ctd\u003e2.6GHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGold 6128\u003c\/td\u003e\n\u003ctd\u003eSR3J4\u003c\/td\u003e\n\u003ctd\u003e6\u003c\/td\u003e\n\u003ctd\u003e3.4GHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGold 6130\u003c\/td\u003e\n\u003ctd\u003eSR3B9\u003c\/td\u003e\n\u003ctd\u003e16\u003c\/td\u003e\n\u003ctd\u003e2.1GHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGold 6130F\u003c\/td\u003e\n\u003ctd\u003eSR3KD\u003c\/td\u003e\n\u003ctd\u003e16\u003c\/td\u003e\n\u003ctd\u003e2.1GHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGold 6130T\u003c\/td\u003e\n\u003ctd\u003eSR3J8\u003c\/td\u003e\n\u003ctd\u003e16\u003c\/td\u003e\n\u003ctd\u003e2.1GHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGold 6132\u003c\/td\u003e\n\u003ctd\u003eSR3J3\u003c\/td\u003e\n\u003ctd\u003e14\u003c\/td\u003e\n\u003ctd\u003e2.6GHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGold 6133\u003c\/td\u003e\n\u003ctd\u003eSR3M1\u003c\/td\u003e\n\u003ctd\u003e20\u003c\/td\u003e\n\u003ctd\u003e2.5GHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGold 6134\u003c\/td\u003e\n\u003ctd\u003eSR3AR\u003c\/td\u003e\n\u003ctd\u003e8\u003c\/td\u003e\n\u003ctd\u003e3.2GHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGold 6136\u003c\/td\u003e\n\u003ctd\u003eSR3B2\u003c\/td\u003e\n\u003ctd\u003e12\u003c\/td\u003e\n\u003ctd\u003e3.0GHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGold 6138\u003c\/td\u003e\n\u003ctd\u003eSR3B5\u003c\/td\u003e\n\u003ctd\u003e20\u003c\/td\u003e\n\u003ctd\u003e2.0GHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGold 6138F\u003c\/td\u003e\n\u003ctd\u003eSR3KK\u003c\/td\u003e\n\u003ctd\u003e20\u003c\/td\u003e\n\u003ctd\u003e2GHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGold 6138P\u003c\/td\u003e\n\u003ctd\u003eSRCUG\u003c\/td\u003e\n\u003ctd\u003e20\u003c\/td\u003e\n\u003ctd\u003e2.0GHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGold 6138T\u003c\/td\u003e\n\u003ctd\u003eSR3J7\u003c\/td\u003e\n\u003ctd\u003e20\u003c\/td\u003e\n\u003ctd\u003e2.0GHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGold 6140\u003c\/td\u003e\n\u003ctd\u003eSR3AX\u003c\/td\u003e\n\u003ctd\u003e18\u003c\/td\u003e\n\u003ctd\u003e2.3GHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGold 6142\u003c\/td\u003e\n\u003ctd\u003eSR3AY\u003c\/td\u003e\n\u003ctd\u003e16\u003c\/td\u003e\n\u003ctd\u003e2.6GHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGold 6142F\u003c\/td\u003e\n\u003ctd\u003eSR3KH\u003c\/td\u003e\n\u003ctd\u003e16\u003c\/td\u003e\n\u003ctd\u003e2.6GHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGold 6144\u003c\/td\u003e\n\u003ctd\u003eSR3MB\u003c\/td\u003e\n\u003ctd\u003e8\u003c\/td\u003e\n\u003ctd\u003e3.5GHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGold 6146\u003c\/td\u003e\n\u003ctd\u003eSR3MA\u003c\/td\u003e\n\u003ctd\u003e12\u003c\/td\u003e\n\u003ctd\u003e3.2GHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGold 6148\u003c\/td\u003e\n\u003ctd\u003eSR3B6\u003c\/td\u003e\n\u003ctd\u003e20\u003c\/td\u003e\n\u003ctd\u003e2.4GHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGold 6148F\u003c\/td\u003e\n\u003ctd\u003eSR3KJ\u003c\/td\u003e\n\u003ctd\u003e20\u003c\/td\u003e\n\u003ctd\u003e2.4GHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGold 6150\u003c\/td\u003e\n\u003ctd\u003eSR37K\u003c\/td\u003e\n\u003ctd\u003e18\u003c\/td\u003e\n\u003ctd\u003e2.7GHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGold 6154\u003c\/td\u003e\n\u003ctd\u003eSR3J5\u003c\/td\u003e\n\u003ctd\u003e18\u003c\/td\u003e\n\u003ctd\u003e3.0GHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePlatinum 8153\u003c\/td\u003e\n\u003ctd\u003eSR3BA\u003c\/td\u003e\n\u003ctd\u003e16\u003c\/td\u003e\n\u003ctd\u003e2.0GHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePlatinum 8156\u003c\/td\u003e\n\u003ctd\u003eSR3AV\u003c\/td\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003ctd\u003e3.6GHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePlatinum 8158\u003c\/td\u003e\n\u003ctd\u003eSR3B7\u003c\/td\u003e\n\u003ctd\u003e12\u003c\/td\u003e\n\u003ctd\u003e3.0GHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"outercontainerOfOneTable\"\u003e\n\u003ch4 class=\"sub-title\"\u003e2nd Generation Intel Xeon Scalable\u003c\/h4\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eCPU\u003c\/th\u003e\n\u003cth\u003eStep Code\u003c\/th\u003e\n\u003cth\u003eCores\u003c\/th\u003e\n\u003cth\u003eFrequency\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eBronze 3204\u003c\/td\u003e\n\u003ctd\u003eSRFBP\u003c\/td\u003e\n\u003ctd\u003e6\u003c\/td\u003e\n\u003ctd\u003e1.9GHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBronze 3206R\u003c\/td\u003e\n\u003ctd\u003eSRG25\u003c\/td\u003e\n\u003ctd\u003e8\u003c\/td\u003e\n\u003ctd\u003e1.9GHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSilver 4208\u003c\/td\u003e\n\u003ctd\u003eSRFBM\u003c\/td\u003e\n\u003ctd\u003e8\u003c\/td\u003e\n\u003ctd\u003e2.1GHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSilver 4209T\u003c\/td\u003e\n\u003ctd\u003eSRFBQ\u003c\/td\u003e\n\u003ctd\u003e8\u003c\/td\u003e\n\u003ctd\u003e2.2GHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSilver 4210\u003c\/td\u003e\n\u003ctd\u003eSRFBL\u003c\/td\u003e\n\u003ctd\u003e10\u003c\/td\u003e\n\u003ctd\u003e2.2GHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSilver 4210R\u003c\/td\u003e\n\u003ctd\u003eSRG24\u003c\/td\u003e\n\u003ctd\u003e10\u003c\/td\u003e\n\u003ctd\u003e2.4GHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSilver 4210T\u003c\/td\u003e\n\u003ctd\u003eSRGYH\u003c\/td\u003e\n\u003ctd\u003e10\u003c\/td\u003e\n\u003ctd\u003e2.3GHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSilver 4214\u003c\/td\u003e\n\u003ctd\u003eSRFB9\u003c\/td\u003e\n\u003ctd\u003e12\u003c\/td\u003e\n\u003ctd\u003e2.2GHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSilver 4214R\u003c\/td\u003e\n\u003ctd\u003eSRG1W\u003c\/td\u003e\n\u003ctd\u003e12\u003c\/td\u003e\n\u003ctd\u003e2.4GHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSilver 4214Y\u003c\/td\u003e\n\u003ctd\u003eSRFDG\u003c\/td\u003e\n\u003ctd\u003e12\u003c\/td\u003e\n\u003ctd\u003e2.2GHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSilver 4215\u003c\/td\u003e\n\u003ctd\u003eSRFBA\u003c\/td\u003e\n\u003ctd\u003e8\u003c\/td\u003e\n\u003ctd\u003e2.5GHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSilver 4215R\u003c\/td\u003e\n\u003ctd\u003eSRGZE\u003c\/td\u003e\n\u003ctd\u003e8\u003c\/td\u003e\n\u003ctd\u003e3.2GHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSilver 4216\u003c\/td\u003e\n\u003ctd\u003eSRFBB\u003c\/td\u003e\n\u003ctd\u003e16\u003c\/td\u003e\n\u003ctd\u003e2.1GHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGold 5215\u003c\/td\u003e\n\u003ctd\u003eSRFBC\u003c\/td\u003e\n\u003ctd\u003e10\u003c\/td\u003e\n\u003ctd\u003e2.5GHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGold 5215L\u003c\/td\u003e\n\u003ctd\u003eSRFBE\u003c\/td\u003e\n\u003ctd\u003e10\u003c\/td\u003e\n\u003ctd\u003e2.5GHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGold 5217\u003c\/td\u003e\n\u003ctd\u003eSRFBF\u003c\/td\u003e\n\u003ctd\u003e8\u003c\/td\u003e\n\u003ctd\u003e3.0GHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGold 5218\u003c\/td\u003e\n\u003ctd\u003eSRF8T\u003c\/td\u003e\n\u003ctd\u003e16\u003c\/td\u003e\n\u003ctd\u003e2.3GHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGold 5218B\u003c\/td\u003e\n\u003ctd\u003eSRFDJ\u003c\/td\u003e\n\u003ctd\u003e16\u003c\/td\u003e\n\u003ctd\u003e2.3GHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGold 5218N\u003c\/td\u003e\n\u003ctd\u003eSRFD9\u003c\/td\u003e\n\u003ctd\u003e16\u003c\/td\u003e\n\u003ctd\u003e2.3GHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGold 5218R\u003c\/td\u003e\n\u003ctd\u003eSRGZ7\u003c\/td\u003e\n\u003ctd\u003e20\u003c\/td\u003e\n\u003ctd\u003e2.1GHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGold 5218T\u003c\/td\u003e\n\u003ctd\u003eSRFPM\u003c\/td\u003e\n\u003ctd\u003e16\u003c\/td\u003e\n\u003ctd\u003e2.1GHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGold 5220\u003c\/td\u003e\n\u003ctd\u003eSRFBJ\u003c\/td\u003e\n\u003ctd\u003e18\u003c\/td\u003e\n\u003ctd\u003e2.2GHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGold 5220S\u003c\/td\u003e\n\u003ctd\u003eSRFPT\u003c\/td\u003e\n\u003ctd\u003e18\u003c\/td\u003e\n\u003ctd\u003e2.7GHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGold 5220T\u003c\/td\u003e\n\u003ctd\u003eSRFPK\u003c\/td\u003e\n\u003ctd\u003e18\u003c\/td\u003e\n\u003ctd\u003e1.9GHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGold 5222\u003c\/td\u003e\n\u003ctd\u003eSRF8V\u003c\/td\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003ctd\u003e3.8GHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGold 6208U\u003c\/td\u003e\n\u003ctd\u003eSRGZD\u003c\/td\u003e\n\u003ctd\u003e16\u003c\/td\u003e\n\u003ctd\u003e2.9GHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGold 6209U\u003c\/td\u003e\n\u003ctd\u003eSRFQ3\u003c\/td\u003e\n\u003ctd\u003e20\u003c\/td\u003e\n\u003ctd\u003e2.1GHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGold 6210U\u003c\/td\u003e\n\u003ctd\u003eSRF9B\u003c\/td\u003e\n\u003ctd\u003e20\u003c\/td\u003e\n\u003ctd\u003e2.5GHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGold 6222V\u003c\/td\u003e\n\u003ctd\u003eSRFQ5\u003c\/td\u003e\n\u003ctd\u003e20\u003c\/td\u003e\n\u003ctd\u003e1.8GHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGold 6226\u003c\/td\u003e\n\u003ctd\u003eSRFPP\u003c\/td\u003e\n\u003ctd\u003e12\u003c\/td\u003e\n\u003ctd\u003e2.7GHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGold 6226R\u003c\/td\u003e\n\u003ctd\u003eSRGZC\u003c\/td\u003e\n\u003ctd\u003e16\u003c\/td\u003e\n\u003ctd\u003e2.9GHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGold 6230\u003c\/td\u003e\n\u003ctd\u003eSRF8W\u003c\/td\u003e\n\u003ctd\u003e20\u003c\/td\u003e\n\u003ctd\u003e2.1GHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGold 6230N\u003c\/td\u003e\n\u003ctd\u003eSRFPR\u003c\/td\u003e\n\u003ctd\u003e20\u003c\/td\u003e\n\u003ctd\u003e2.3GHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGold 6230T\u003c\/td\u003e\n\u003ctd\u003eSRFPS\u003c\/td\u003e\n\u003ctd\u003e20\u003c\/td\u003e\n\u003ctd\u003e2.1GHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGold 6234\u003c\/td\u003e\n\u003ctd\u003eSRFPN\u003c\/td\u003e\n\u003ctd\u003e8\u003c\/td\u003e\n\u003ctd\u003e3.3GHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGold 6240\u003c\/td\u003e\n\u003ctd\u003eSRF8X\u003c\/td\u003e\n\u003ctd\u003e18\u003c\/td\u003e\n\u003ctd\u003e2.6GHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGold 6240L\u003c\/td\u003e\n\u003ctd\u003eSRFQ0\u003c\/td\u003e\n\u003ctd\u003e18\u003c\/td\u003e\n\u003ctd\u003e2.6GHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGold 6240Y\u003c\/td\u003e\n\u003ctd\u003eSRF9D\u003c\/td\u003e\n\u003ctd\u003e18\u003c\/td\u003e\n\u003ctd\u003e2.6GHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGold 6242\u003c\/td\u003e\n\u003ctd\u003eSRF8Y\u003c\/td\u003e\n\u003ctd\u003e16\u003c\/td\u003e\n\u003ctd\u003e2.8GHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGold 6242R\u003c\/td\u003e\n\u003ctd\u003eSRGZJ\u003c\/td\u003e\n\u003ctd\u003e20\u003c\/td\u003e\n\u003ctd\u003e3.1GHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGold 6244\u003c\/td\u003e\n\u003ctd\u003eSRF8Z\u003c\/td\u003e\n\u003ctd\u003e8\u003c\/td\u003e\n\u003ctd\u003e3.6GHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGold 6246\u003c\/td\u003e\n\u003ctd\u003eSRFPJ\u003c\/td\u003e\n\u003ctd\u003e12\u003c\/td\u003e\n\u003ctd\u003e3.3GHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGold 6246R\u003c\/td\u003e\n\u003ctd\u003eSRGZL\u003c\/td\u003e\n\u003ctd\u003e16\u003c\/td\u003e\n\u003ctd\u003e3.4GHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGold 6248\u003c\/td\u003e\n\u003ctd\u003eSRF90\u003c\/td\u003e\n\u003ctd\u003e20\u003c\/td\u003e\n\u003ctd\u003e2.5GHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGold 6250\u003c\/td\u003e\n\u003ctd\u003eSRGTR\u003c\/td\u003e\n\u003ctd\u003e8\u003c\/td\u003e\n\u003ctd\u003e3.9GHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGold 6250L\u003c\/td\u003e\n\u003ctd\u003eSRH5D\u003c\/td\u003e\n\u003ctd\u003e8\u003c\/td\u003e\n\u003ctd\u003e3.9GHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGold 6254\u003c\/td\u003e\n\u003ctd\u003eSRF92\u003c\/td\u003e\n\u003ctd\u003e18\u003c\/td\u003e\n\u003ctd\u003e3.1GHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGold 6256\u003c\/td\u003e\n\u003ctd\u003eSRGTQ\u003c\/td\u003e\n\u003ctd\u003e12\u003c\/td\u003e\n\u003ctd\u003e3.6GHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePlatinum 8253\u003c\/td\u003e\n\u003ctd\u003eSRF93\u003c\/td\u003e\n\u003ctd\u003e16\u003c\/td\u003e\n\u003ctd\u003e2.2GHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePlatinum 8256\u003c\/td\u003e\n\u003ctd\u003eSRF94\u003c\/td\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003ctd\u003e3.8GHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c!-- Memory Section Order 3 --\u003e\n\u003cdiv class=\"head-content-set\"\u003e\n\u003ch3\u003eMemory\u003c\/h3\u003e\n\u003cdiv class=\"head-content-set-content\"\u003e\n\u003ch4\u003e\u003cstrong\u003eDIMM Slots \u0026amp; Channels\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003eThe Dell PowerEdge R540 has a total of 16 DIMM slots with a total of six memory channels. Each memory channel consist of two DIMM slots.\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eMemory Types \u0026amp; Module Capacities\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003eThe R540 accepts DDR4 memory. ECC Registered (RDIMMs) and Load Reduced (LRDIMMs) are supported by this server, but the two types cannot be mixed. Mixing memory types can lead to boot failure. With load reduced memory, an overall greater capacity can be achieved when compared to ECC registered. Module capacities of 8GB, 16GB, 32GB, and 64GB can be used. It is important to note that 64GB modules can only be installed as an LRDIMM.\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eMax Configurations\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003eWith load reduced memory, a maximum configuration of 1024GB can be achieved via 16 x 64GB modules. With ECC Registered, 512GB is the max that you can achieve with a configuration of 16 x 32GB modules.\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSupported Memory Speeds\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003eThe Dell PowerEdge accepts memory speeds of 2133MT\/s, 2400MT\/s, 2666MT\/s, 2933MT\/s, and 3200MT\/s. Do note, that 2666MT\/s is the fastest possible speed for this system, meaning that 2933MT\/s and 3200MT\/s will clock down. Another factor that affects the max memory speed of the system, is the processor that is installed. For example, if the installed processor supports a max speed of 2400MT\/s and a 2666MT\/s module is installed, the module will operate at 2400MT\/s.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c!-- Storage Section Order 4 --\u003e\n\u003cdiv class=\"head-content-set\"\u003e\n\u003ch3\u003eStorage\u003c\/h3\u003e\n\u003cdiv class=\"head-content-set-content\"\u003e\n\u003ch4 class=\"sub-title\"\u003e\u003cstrong\u003eSupported Drives\u003c\/strong\u003e\u003c\/h4\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eType\u003c\/th\u003e\n\u003cth\u003eSpeeds\u003c\/th\u003e\n\u003cth\u003eMax Capacity (Per Drive) 2.5\"\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSAS\u003c\/td\u003e\n\u003ctd\u003e7.2K, 10K, 15K\u003c\/td\u003e\n\u003ctd\u003e2.4TB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSATA\u003c\/td\u003e\n\u003ctd\u003e7.2K\u003c\/td\u003e\n\u003ctd\u003e2TB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSSD\u003c\/td\u003e\n\u003ctd\u003e6GB\/s, 12GB\/s\u003c\/td\u003e\n\u003ctd\u003e7.68TB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eType\u003c\/th\u003e\n\u003cth\u003eSpeeds\u003c\/th\u003e\n\u003cth\u003eMax Capacity (Per Drive) 3.5\"\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSAS\u003c\/td\u003e\n\u003ctd\u003e7.2K\u003c\/td\u003e\n\u003ctd\u003e18TB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSATA\u003c\/td\u003e\n\u003ctd\u003e7.2K\u003c\/td\u003e\n\u003ctd\u003e16TB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSSD\u003c\/td\u003e\n\u003ctd\u003e6GB\/s, 12GB\/s\u003c\/td\u003e\n\u003ctd\u003e3.84TB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c!-- Storage Section Order 4 --\u003e \u003c!--\u003cdiv class=\"head-content-set\"\u003e\n \u003ch2\u003e\u003cspan data-mce-fragment=\"1\"\u003eNVMe Options \u0026amp; Upgrades\u003c\/span\u003e\u003c\/h2\u003e\n \u003cdiv class=\"head-content-set-content\"\u003e\n \u003cp\u003e\n NVMe is an amazing storage technology that has a ton of benefits. It is blazing fast which is desirable\n in certain enterprise environments. NVMe drives are much faster compared to traditional drives.\n Unfortunately there isn’t much NVMe support for the PowerEdge R540 server. There is only one option\n which is: PCIe NVMe. Neither U.2 or M.2 will work with this server.\n \u003c\/p\u003e\n \n \u003ch6\u003e\u003cstrong\u003ePCIe NVMe\u003c\/strong\u003e\u003c\/h6\u003e\n \u003cp\u003e\n The only NVMe solution for the PowerEdge R540 is to use a PCIe NVMe drive. Even though this will work,\n there are quite a few limitations. First of all, you cannot use any PCIe NVMe drive of your choice. You can\n only use drives that have Dell firmware. A non-Dell, OEM drive will not work. Even with a PCIe NVMe\n drive with Dell firmware, you are still restricted. You cannot use the drive to install an operating\n system or to create a virtual machine. The only thing that this NVMe solution can be used for is\n additional storage. One thing to check is to make sure that the slot disablement setting in the BIOS is\n enabled. If it is disabled, the drive will not be recognized by the server.\n \u003c\/p\u003e\n \u003c\/div\u003e\n \u003c\/div\u003e\n --\u003e \u003c!-- Systems Management Solutions Section Order 7 --\u003e\n\u003cdiv class=\"head-content-set\"\u003e\n\u003ch3\u003ePower Supplies\u003c\/h3\u003e\n\u003cdiv class=\"head-content-set-content\"\u003e\n\u003ch4\u003e\u003cstrong\u003ePower Supplies Overview\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003eThe Dell PowerEdge R540 server supports up to two hot-swap power supplies. Hot-swap power supplies can be installed or removed, if one power supply unit remains plugged into the system. Power supply options for the R540 are: 450W AC Cabled, 495W AC, 750W AC, 750W Mixed Mode HVDC (China Only), 750W Mixed Mode (DC input for China Only), 1100W AC, 1100W Mixed Mode HVDC.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c!-- Storage Section Order 5 --\u003e\n\u003cdiv class=\"head-content-set\"\u003e\n\u003ch3\u003eRAID Options\u003c\/h3\u003e\n\u003cdiv class=\"head-content-set-content\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eRAID Options\u003c\/th\u003e\n\u003cth\u003eRAID Levels\u003c\/th\u003e\n\u003cth\u003eCache\u003c\/th\u003e\n\u003cth\u003eDrive Speeds\u003c\/th\u003e\n\u003cth\u003ePCIe Generation\u003c\/th\u003e\n\u003cth\u003eRAID Hardware\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eS140 onboard software\u003c\/td\u003e\n\u003ctd\u003e0,1,5,10\u003c\/td\u003e\n\u003ctd\u003eNone\u003c\/td\u003e\n\u003ctd\u003e6 Gb\/s SATA\u003cbr\u003e12 Gb\/s SAS\u003c\/td\u003e\n\u003ctd\u003ePCIe 3.0\u003c\/td\u003e\n\u003ctd\u003eSoftware\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHBA330\u003c\/td\u003e\n\u003ctd\u003ePassthrough\u003c\/td\u003e\n\u003ctd\u003eNone\u003c\/td\u003e\n\u003ctd\u003e6 Gb\/s SATA\u003cbr\u003e12 Gb\/s SAS\u003c\/td\u003e\n\u003ctd\u003ePCIe 3.0\u003c\/td\u003e\n\u003ctd\u003eHardware\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHBA350i\u003c\/td\u003e\n\u003ctd\u003ePassthrough\u003c\/td\u003e\n\u003ctd\u003eNone\u003c\/td\u003e\n\u003ctd\u003e3 Gb\/s SAS\u003cbr\u003e6 Gb\/s SAS\/SATA\u003cbr\u003e12 Gb\/s\u003c\/td\u003e\n\u003ctd\u003ePCIe 4.0\u003c\/td\u003e\n\u003ctd\u003eHardware\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHBA355e\u003c\/td\u003e\n\u003ctd\u003ePassthrough\u003c\/td\u003e\n\u003ctd\u003eNone\u003c\/td\u003e\n\u003ctd\u003e3 Gb\/s SAS\/SATA\u003cbr\u003e6 Gb\/s SAS\/SATA\u003cbr\u003e12 Gb\/s SAS\u003c\/td\u003e\n\u003ctd\u003ePCIe 4.0\u003c\/td\u003e\n\u003ctd\u003eHardware\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e12 Gb\/s Ext SAS HBA\u003c\/td\u003e\n\u003ctd\u003ePassthrough\u003c\/td\u003e\n\u003ctd\u003eNone\u003c\/td\u003e\n\u003ctd\u003e12 Gb\/s SAS\u003c\/td\u003e\n\u003ctd\u003ePCIe 3.0\u003c\/td\u003e\n\u003ctd\u003eHardware\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eH330\u003c\/td\u003e\n\u003ctd\u003e0,1,5,10,50\u003c\/td\u003e\n\u003ctd\u003eNone\u003c\/td\u003e\n\u003ctd\u003e6 Gb\/s SATA\u003cbr\u003e12 Gb\/s SAS\u003c\/td\u003e\n\u003ctd\u003ePCIe 3.0\u003c\/td\u003e\n\u003ctd\u003eHardware\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eH730P\u003c\/td\u003e\n\u003ctd\u003e0,1,5,6,10,50,60\u003c\/td\u003e\n\u003ctd\u003e2GB\u003c\/td\u003e\n\u003ctd\u003e6 Gb\/s SATA \u003cbr\u003e 12 Gb\/s SAS\u003c\/td\u003e\n\u003ctd\u003ePCIe 3.0\u003c\/td\u003e\n\u003ctd\u003eHardware\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eH740P\u003c\/td\u003e\n\u003ctd\u003e0,1,5,6,10,50,60\u003c\/td\u003e\n\u003ctd\u003e8GB\u003c\/td\u003e\n\u003ctd\u003e6 Gb\/s SATA\u003cbr\u003e12 Gb\/s SAS\u003c\/td\u003e\n\u003ctd\u003ePCIe 3.1\u003c\/td\u003e\n\u003ctd\u003eHardware\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eH840\u003c\/td\u003e\n\u003ctd\u003e0,1,5,6,10,50,60\u003c\/td\u003e\n\u003ctd\u003e8GB\u003c\/td\u003e\n\u003ctd\u003e6 Gb\/s SATA\u003cbr\u003e12 Gb\/s SAS\u003c\/td\u003e\n\u003ctd\u003ePCIe 3.1\u003c\/td\u003e\n\u003ctd\u003eHardware\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eH350\u003c\/td\u003e\n\u003ctd\u003e0,1,10\u003c\/td\u003e\n\u003ctd\u003eNone\u003c\/td\u003e\n\u003ctd\u003e6 Gb\/s SATA\u003cbr\u003e12 Gb\/s SAS\u003c\/td\u003e\n\u003ctd\u003ePCIe 4.0\u003c\/td\u003e\n\u003ctd\u003eHardware\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eH750\u003c\/td\u003e\n\u003ctd\u003e0,1,5,6,10,50,60\u003c\/td\u003e\n\u003ctd\u003e8GB\u003c\/td\u003e\n\u003ctd\u003e3 Gb\/s SAS\/SATA\u003cbr\u003e6 Gb\/s SAS\/SATA\u003cbr\u003e12 Gb\/s SAS\u003c\/td\u003e\n\u003ctd\u003ePCIe 4.0\u003c\/td\u003e\n\u003ctd\u003eHardware\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c!-- Network Interface Card Options Section Order 6 --\u003e\n\u003cdiv class=\"head-content-set\"\u003e\n\u003ch3\u003eNetwork Interface Card Options\u003c\/h3\u003e\n\u003cdiv class=\"head-content-set-content\"\u003e\n\u003cp\u003eThe Dell PowerEdge R540 has two 1GbE RJ45 ports that are built into the server's motherboard. For additional networking capabilities, the PowerEdge R540 supports a single LOM riser card as well as PCIe network cards that can be installed in any of the system's PCIe slots.\u003c\/p\u003e\n\u003cdiv class=\"outercontainerOfTwoTable\"\u003e\n\u003cdiv class=\"outercontainerOfOneTable\"\u003e\n\u003ch4 class=\"sub-title\"\u003eMezzanine Cards\u003c\/h4\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eBroadcom 5720 Dual Port 2x1GbE RJ45\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBroadcom 57414 Dual Port 2x10\/25GbE SFP28\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBroadcom 57416 Dual Port 2x10GbE RJ45\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBroadcom 57416 Dual Port 2x10GbE SFP+\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"outercontainerOfOneTable\"\u003e\n\u003ch4 class=\"sub-title\"\u003ePCIe Cards\u003c\/h4\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eBroadcom 5719 Quad Port 4x1GbE RJ45 Low Profile\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBroadcom 5720 Dual Port 2x1GbE RJ45 Low Profile\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBroadcom 57412 Dual Port 2x10GbE SFP+ Low Profile\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBroadcom 57414 Dual Port 2x10\/25GbE SFP28 Low Profile\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBroadcom 57416 Dual Port 2x10GbE RJ45 Low Profile\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eQLogic 2690 Single Port 1x16Gb FC HBA Low Profile V2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eQLogic 2692 Dual Port 2x16Gb FC HBA Low Profile V2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c!-- Systems Management Solutions Section Order 7 --\u003e\n\u003cdiv class=\"head-content-set\"\u003e\n\u003ch3\u003eSystems Management Solutions\u003c\/h3\u003e\n\u003cp class=\"head-content-set-content\"\u003eThe Dell PowerEdge R540 Server utilizes the Integrated Dell Remote Access Controller 9 (iDRAC9), which allows you to easily manage your Dell server. The iDRAC9 web interface provides a variety of useful information and features, that make managing your Dell server an easy task. Features include, but are not limited to hardware monitoring, power control, remote console, control over system settings, firmware update control, storage management, and much more. You can access the iDRAC9 web interface, by setting this iDRAC IP in system setup and searching the IP in a web browser.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c!-- Systems Management Solutions Section Order 8 --\u003e\n\u003cdiv class=\"head-content-set\"\u003e\n\u003ch3\u003eSupported Operating Systems:\u003c\/h3\u003e\n\u003cp class=\"head-content-set-content\"\u003eThe Dell PowerEdge R540 Server supports a wide variety of operating systems which ranges from different distributions of Linux, VMware, and Windows Server. The operating systems include, but are not limited to:\u003c\/p\u003e\n\u003cul class=\"custom_dots\"\u003e\n\u003cli\u003e⦿ Citrix XenServer 6.5\u003c\/li\u003e\n\u003cli\u003e⦿ Citrix XenServer 7.0\u003c\/li\u003e\n\u003cli\u003e⦿ Novell SuSE Linux ES 11\u003c\/li\u003e\n\u003cli\u003e⦿ Red Hat® Enterprise Linux 6\u003c\/li\u003e\n\u003cli\u003e⦿ Red Hat® Enterprise Linux 7\u003c\/li\u003e\n\u003cli\u003e⦿ Red Hat® Enterprise Linux 8\u003c\/li\u003e\n\u003cli\u003e⦿ SUSE Linux ES 12\u003c\/li\u003e\n\u003cli\u003e⦿ SUSE Linux ES 15\u003c\/li\u003e\n\u003cli\u003e⦿ VMware ESXi 5.1\u003c\/li\u003e\n\u003cli\u003e⦿ VMware ESXi 5.5\u003c\/li\u003e\n\u003cli\u003e⦿ VMware ESXi 6.0\u003c\/li\u003e\n\u003cli\u003e⦿ VMware ESXi 6.5\u003c\/li\u003e\n\u003cli\u003e⦿ VMware ESXi 6.7\u003c\/li\u003e\n\u003cli\u003e⦿ Window Server 2008 R2\u003c\/li\u003e\n\u003cli\u003e⦿ Window Server 2012\u003c\/li\u003e\n\u003cli\u003e⦿ Window Server 2012 R2\u003c\/li\u003e\n\u003cli\u003e⦿ Window Server 2016\u003c\/li\u003e\n\u003cli\u003e⦿ Window Server 2019 LTSC\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Dell","offers":[{"title":"8 Bay LFF","offer_id":49102946697433,"sku":"Dell-R540-8B-LFF","price":1020.6,"currency_code":"USD","in_stock":true},{"title":"12 Bay LFF","offer_id":49102946730201,"sku":"Dell-R540-12B-LFF","price":1134.0,"currency_code":"USD","in_stock":true}],"url":"https:\/\/www.aloinfousa.com\/products\/dell-poweredge-r540-server-5bolm","provider":"aloinfousa.com","version":"1.0","type":"link"}