{"product_id":"cisco-iem-3300-8p-expansion-module-acdhr","title":"Cisco IEM-3300-8P Expansion Module","description":"\u003ch2\u003eCisco IEM-3300-8P Expansion Module\u003c\/h2\u003e\n\u003cp\u003e\u003cspan data-preserver-spaces=\"true\"\u003eThe Cisco Catalyst IE3300 Rugged Series expansion modules are designed for harsh industrial environments such as manufacturing, energy, transportation, mining, smart cities, and oil and gas. It is fanless, convection-cooled, and hardened for vibration, shock, surge, and electrical noise immunity. The Cisco IEM-3300-8P= has 8 PoE\/PoE+100\/1000Mbps ports, expanding the switch to 18 ports.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e\u003cspan data-preserver-spaces=\"true\"\u003eKey Features:\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan data-preserver-spaces=\"true\"\u003eUp to 480 Watts total PoE budget \u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan data-preserver-spaces=\"true\"\u003eFor IE3300 and IE3400 base switch\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan data-preserver-spaces=\"true\"\u003eIPv6 Ready Logo Certified\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan data-preserver-spaces=\"true\"\u003e\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003eProduct Details\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eProperties\u003c\/td\u003e\n\u003ctd\u003eCisco IEM-3300-8P=\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDescription\u003c\/td\u003e\n\u003ctd\u003eCatalyst IE3300 w\/ 8 GE PoE\/PoE+ Copper ports, Expansion Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Family\u003c\/td\u003e\n\u003ctd\u003eIndustrial Ethernet 3300\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eEthernet Switch Expansion Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003eSwitches\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTotal ports on expansion module\u003c\/td\u003e\n\u003ctd\u003e8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCopper (RJ45)\u003cbr\u003e10\/100\/1000Mbps\u003c\/td\u003e\n\u003ctd\u003e8 (PoE\/PoE+)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSFP\u003cbr\u003e100\/1000Mbps\u003c\/td\u003e\n\u003ctd\u003e-\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCopper (RJ45)\u003cbr\u003e1GE\/2.5G (with up to 802.3bt type 4 PoE)\u003c\/td\u003e\n\u003ctd\u003e-\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTotal system ports (including expansion module)\u003c\/td\u003e\n\u003ctd\u003e18\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePoE \/ PoE (+) budget\u003c\/td\u003e\n\u003ctd\u003eSupported with IE3300 PoE base modules to provide a total PoE budget of 360W with the all GE base and up to 480Watts with IE3300 10G base and IE3400 PoE base\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (HxWxD) Inches\u003c\/td\u003e\n\u003ctd\u003e6 in. X 2.6 in. X 5.3 in.\u003cbr\u003e15.2 cm. X 6.6 cm. X 13.5 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e2.0 lbs (0.91 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003eDIN Rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSpecifications\u003c\/td\u003e\n\u003ctd\u003eIE-3300-8P=\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e14W (Power consumption for non PoE supported model is measured at 12V and for the PoE supported model is measured at 54V.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-40°C to +70°C (40 LFM vented enclosure)\u003cbr\u003e-40°C to +60°C (sealed enclosure)\u003cbr\u003e-34°C to +75°C (Min. 200 LFM fan or blower-equipped enclosure)\u003cbr\u003e+85°C (type tested for 16 hours)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e-40 C to +85 C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Altitude\u003c\/td\u003e\n\u003ctd\u003eUp to 15,000 feet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Altitude\u003c\/td\u003e\n\u003ctd\u003e15,000 feet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMean Time Between Failures (MTBF)\u003c\/td\u003e\n\u003ctd\u003e2,931,233\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIndustrial Automation Control\u003cbr\u003eSystem\u003c\/td\u003e\n\u003ctd\u003eIEC 62443-4-1\u003cbr\u003eIEC 62443-4-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectromagnetic emissions\u003c\/td\u003e\n\u003ctd\u003eFCC 47 CFR Part 15 subpart B Class A\u003cbr\u003eEN 55032\/CISPR 32 Class A\u003cbr\u003eVCCI Class A\u003cbr\u003eAS\/NZS CISPR 32 Class A\u003cbr\u003eCISPR 11 Class A\u003cbr\u003eICES 003 Class A\u003cbr\u003eCNS 13438 Class A\u003cbr\u003eKN 32 Class A\u003cbr\u003eEN 300 386\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectromagnetic immunity\u003c\/td\u003e\n\u003ctd\u003eCISPR 24\u003cbr\u003eEN 55024\u003cbr\u003eKN 35\u003cbr\u003eEN 61000-4-2 Electro Static Discharge (air 15kV, contact 8kV)\u003cbr\u003eEN 61000-4-3 Radiated RF (10V\/m UTP, 20V\/m STP)\u003cbr\u003eEN 61000-4-4 Electromagnetic Fast Transients (4kV)\u003cbr\u003eEN 61000-4-5 Surge (2KV\/1KV Power, 4KV STP)\u003cbr\u003eEN 61000-4-6 Conducted RF (10Vrms UTP)\u003cbr\u003eEN 61000-4-10 Damped Oscillatory Magnetic Field (100 A\/m)\u003cbr\u003eEN 61000-4-16 Conducted CM Disturbances (30V, Cont\/300V, 1 sec)\u003cbr\u003eEN 61000-4-17 Ripple Immunity DC Power (10%)\u003cbr\u003eEN 61000-4-18 Damped Oscillatory Wave (2.5kV, 1MHz)\u003cbr\u003eEN-61000-4-29 DC Voltage Dips and interruptions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIndustry standards\u003c\/td\u003e\n\u003ctd\u003eEN 61000-6-2 Industrial Immunity\u003cbr\u003eEN 61000-6-4 Industrial Emissions\u003cbr\u003eEN 61000-6-1 Light Industrial Immunity\u003cbr\u003eEN 61326-1 Measurement, Control and Laboratory Equipment\u003cbr\u003eIEEE 1613 Electric Power Stations Communications Networking\u003cbr\u003eEN\/IEC 61850-3 Electric Substations Communications Networking\u003cbr\u003eEN50121-4 Railway Signaling and Telecommunications Apparatus\u003cbr\u003eEN50155- Railway applications - Rolling stock\u003cbr\u003eODVA Industrial EtherNet\/IP\u003cbr\u003eNEMA TS 2-2016\u003cbr\u003eIP30\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMarine I\u003c\/td\u003e\n\u003ctd\u003eDNC Certification according to class guideline DNV-CG-0339\u003cbr\u003eAdditional Standards:\u003cbr\u003eIEC 60945, IACS UR E10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety standards and\u003cbr\u003ecertifications\u003cbr\u003e\n\u003c\/td\u003e\n\u003ctd\u003eInformation technology equipment:\u003cbr\u003eUL\/CSA 60950-1, IEC 60950-1 CB with all country deviations\u003cbr\u003eUL\/CSA 62368-1, IEC 62368-1 CB with all country deviations\u003cbr\u003eIndustrial floor (control equipment):\u003cbr\u003eUL\/CSA 61010-2-201\u003cbr\u003eCB report and certificate to IEC\/EN 61010-2-201\u003cbr\u003eHazardous locations:\u003cbr\u003eUL121201 (Class l, Div 2, groups A-D)\u003cbr\u003eCSA 213 (Class l, Div 2, groups A-D)\u003cbr\u003eUL\/CSA 60079-0, -15 (Class l, Zone 2, Gc\/IIC)\u003cbr\u003eIEC 60079-0, -15 IECEx test report (Class l, Zone 2, Gc\/IIC)\u003cbr\u003eEN 60079-0, -15 ATEX certificate (Class l, Zone 2, Gc\/IIC) Cabinet enclosure required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHumidity\u003c\/td\u003e\n\u003ctd\u003eRelative humidity of 5% to 95% non-condensing\u003cbr\u003eIEC 60068-2-78\u003cbr\u003eIEC 60068-2-30\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShock and vibration\u003c\/td\u003e\n\u003ctd\u003eIEC 60068-2-27 (operational shock, 50G, 3ms, half sine)\u003cbr\u003eIEC 60068-2-27 (non-operational shock, 65-80G, 9ms, trapezoidal)\u003cbr\u003eMIL-STD-810, Method 514.4\u003cbr\u003eIEC 60068-2-6 (vibration-sinusiodal, 5Hz-150Hz)\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCorrosion\u003c\/td\u003e\n\u003ctd\u003eIEC 60068-2-52 (salt fog)\u003cbr\u003eIEC 60068-2-60 (flowing mixed gas)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eCompatible Accessories\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003eAccessories and License Upgrade PIDs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSTK-RACK-DINRAIL\u003c\/td\u003e\n\u003ctd\u003e19 in. DIN Rail mount kit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003eIE-3300 Series Power Supplies\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePWR-IE50W-AC\u003c\/td\u003e\n\u003ctd\u003e50W AC Power Supply\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePWR-IE50W-AC-IEC=\u003c\/td\u003e\n\u003ctd\u003e50W AC-IEC Power Supply\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePWR-IE50W-AC-L\u003c\/td\u003e\n\u003ctd\u003e50W AC-L Power Supply\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePWR-IE65W-PC-AC\u003c\/td\u003e\n\u003ctd\u003e65W PC-AC Power Supply\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePWR-IE65W-PC-DC\u003c\/td\u003e\n\u003ctd\u003e65W PC-DC Power Supply\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePWR-IE170W-PC- AC\u003c\/td\u003e\n\u003ctd\u003e170W PC-AC Power Supply\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePWR-IE170W-PC- DC\u003c\/td\u003e\n\u003ctd\u003e170W PC-DC Power Supply\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePWR-IE240W-PCAC-L\u003c\/td\u003e\n\u003ctd\u003e240W PCAC-L Power Supply\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePWR-IE480W-PCAC-L\u003c\/td\u003e\n\u003ctd\u003e480W PCAC-L Power Supply\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e*Expansion modules require an additional power supply separate from the main module's power supply.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Cisco","offers":[{"title":"Default Title","offer_id":48013268910297,"sku":"IEM-3300-8P-NEW","price":2915.75,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0016\/5327\/6707\/files\/iem-3300-8p_1_51d30948-2775-49d1-895c-f99aaf8dfe75.webp?v=1771853018","url":"https:\/\/www.aloinfousa.com\/pt-br\/products\/cisco-iem-3300-8p-expansion-module-acdhr","provider":"aloinfousa.com","version":"1.0","type":"link"}