{"product_id":"juniper-ex9204-red3b-ac-chassis-hmbvd","title":"Juniper EX9204-RED3B-AC Chassis","description":"\u003ch3\u003eProduct Details\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eProperties\u003c\/td\u003e\n\u003ctd\u003eJuniper EX9204-RED3B-AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDescription\u003c\/td\u003e\n\u003ctd\u003eRedundant EX9204 system configuration: 4-slot chassis with passive midplane and 1x fan tray, 2x EX9200-RE2 Routing Engines, 2x Switch Fabric-2 modules, 4x 2,520W AC PSUs, and all necessary blank panels.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Family\u003c\/td\u003e\n\u003ctd\u003eEX9200 Series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eEthernet Switch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTotal number of slots\u003c\/td\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSlots available for line cards\u003c\/td\u003e\n\u003ctd\u003e2 with fabric redundancy (3 without)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRouting Engine\u003c\/td\u003e\n\u003ctd\u003e2x EX9200-RE2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSwitch Fabric Module\u003c\/td\u003e\n\u003ctd\u003e2x EX9200-SF2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003eMaximum GbE Port Density (wire speed)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1GbE\u003c\/td\u003e\n\u003ctd\u003e120\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e10GbE\u003c\/td\u003e\n\u003ctd\u003e144 (96)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e25GbE\u003c\/td\u003e\n\u003ctd\u003e120\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e40GbE\u003c\/td\u003e\n\u003ctd\u003e30\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e100GbE\u003c\/td\u003e\n\u003ctd\u003e30\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFabric\u003c\/td\u003e\n\u003ctd\u003e• Up to 3 Tbps backplane capacity\u003cbr\u003e • Up to 1.5 Tbps (full duplex) per slot fabric capacity\u003cbr\u003e • 1+1 fabric redundancy\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRouting Engine\u003c\/td\u003e\n\u003ctd\u003e• Master and backup Routing Engines (1+1 redundancy)\u003cbr\u003e • Up to 64 gigabytes DRAM\u003cbr\u003e • Dual front pluggable solid-state drive (SSD) (Up to 64 GB each)\u003cbr\u003e • Console, auxiliary serial, and Ethernet management ports\u003cbr\u003e • USB storage interface\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating system\u003c\/td\u003e\n\u003ctd\u003eJuniper Networks Junos operating system\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower\u003c\/td\u003e\n\u003ctd\u003e Holds up to four power supplies:\u003cbr\u003e • 100-120 V AC (2+2 redundancy)\u003cbr\u003e • 200-240 V AC (1+1 redundancy)\u003cbr\u003e Maximum power draw: 2,421 W (AC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCooling\u003c\/td\u003e\n\u003ctd\u003e• Front-to-back airflow\u003cbr\u003e • Hot-swappable fan tray with 1+1 redundancy\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W x H x D) \u003c\/td\u003e\n\u003ctd\u003e17.5 x 8.7 x 27.75 in\u003cbr\u003e (44.5 x 22.1 x 70.5 cm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight (fully loaded)\u003c\/td\u003e\n\u003ctd\u003e128.0 lbs (58.1 Kg) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRack units\u003c\/td\u003e\n\u003ctd\u003e5 U\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003ePower Consumption\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEX9204 Redundant Typical Power\u003c\/td\u003e\n\u003ctd\u003e690 W \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEX9204 Redundant Reserved Power\u003c\/td\u003e\n\u003ctd\u003e690 W \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAdditional Units\u003c\/td\u003e\n\u003ctd\u003eTypical Power\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEX9200 Routing Engine-2\u003c\/td\u003e\n\u003ctd\u003e90 W \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEX9200 Switch Fabric-2\u003c\/td\u003e\n\u003ctd\u003e155 W \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAdditional Units\u003c\/td\u003e\n\u003ctd\u003eMaximum Power\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEX9200 Routing Engine-2\u003c\/td\u003e\n\u003ctd\u003e90 W \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEX9200 Switch Fabric-2\u003c\/td\u003e\n\u003ctd\u003e155 W \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003ePower Supply Capacity\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e100-120V AC Input\u003c\/td\u003e\n\u003ctd\u003e1,167 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e200-240 V AC Input\u003c\/td\u003e\n\u003ctd\u003e2,050 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e-40 to -72 V DC Input\u003c\/td\u003e\n\u003ctd\u003e2,400 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003eMaximum number of line cards in a chassis\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEX9200-40XS\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEX9200-15C\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEX9200-12QS\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEX9200-32XS\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEX9200-6QS\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEX9200-2C-8XS\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEX9200-40T\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEX9200-40F\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEX9200-MPC\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSpecifications\u003c\/td\u003e\n\u003ctd\u003eEX9204-RED3B-AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBackplane capacity\u003c\/td\u003e\n\u003ctd\u003eUp to 3 Tbps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum fabric bandwidth\/slot\u003c\/td\u003e\n\u003ctd\u003e1.5 Tbps\/slot\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSwitch fabric throughput per slot\u003c\/td\u003e\n\u003ctd\u003e480 Gbps (EX9200-SF2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRE DRAM\u003c\/td\u003e\n\u003ctd\u003e64 GB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRE CPU\u003c\/td\u003e\n\u003ctd\u003e2 GHz, six-core\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRE Storage\u003c\/td\u003e\n\u003ctd\u003e64 GB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003eSoftware Features\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHigh availability\u003c\/td\u003e\n\u003ctd\u003eHardware designed for continuous operation:\u003cbr\u003e • Secure, modular architecture that isolates faults\u003cbr\u003e • Separate control and forwarding planes that enhance scalability and resiliency\u003cbr\u003e • Transparent failover and network recovery\u003cbr\u003e • Graceful Routing Engine switchover (GRES)\u003cbr\u003e • Nonstop active routing (NSR)\u003cbr\u003e • Nonstop bridging (NSB)\u003cbr\u003e • Unified in-service software upgrade (unified ISSU)*\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLayer 2 Features\u003c\/td\u003e\n\u003ctd\u003eUp to 1 million media access control (MAC) addresses\u003cbr\u003e Up to 512,000 Address Resolution Protocol (ARP) entries with ML license (256,000 entries without ML license)\u003cbr\u003e Up to 512,000 Forwarding Information Block (FIB) entries with ML license (256,000 entries without ML license)\u003cbr\u003e Jumbo frames (9,192 bytes maximum)\u003cbr\u003e 32,000 VLANs\u003cbr\u003e VLAN Registration Protocol\u003cbr\u003e 3ad – Link Aggregation Control Protocol (LACP)\u003cbr\u003e 1D – Spanning Tree Protocol (STP)\u003cbr\u003e 1w – Rapid Spanning Tree Protocol (RSTP)\u003cbr\u003e 1s – Multiple Spanning Tree Protocol (MSTP)\u003cbr\u003e VLAN Spanning Tree Protocol (VSTP)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLayer 3 Features\u003c\/td\u003e\n\u003ctd\u003e1 million IPv4 routing information base (RIB)\u003cbr\u003e 1 million IPv6 RIB\u003cbr\u003e Static routing\u003cbr\u003e RIP v1\/v2\u003cbr\u003e OSPF v1\/v2\u003cbr\u003e OSPF v3\u003cbr\u003e Filter-based forwarding\u003cbr\u003e Virtual Router Redundancy Protocol (VRRP)*\u003cbr\u003e IPv6\u003cbr\u003e Bidirectional Forwarding Detection (BFD)\u003cbr\u003e Virtual routers\u003cbr\u003e BGP (Advanced Feature license)\u003cbr\u003e IS-IS (Advanced Feature license)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHardware tunneling\u003c\/td\u003e\n\u003ctd\u003eGRE tunnels\u003cbr\u003e MPLS capabilities (Advanced Feature License)\u003cbr\u003e VPLS\u003cbr\u003e BGP\/MPLS VPNs\u003cbr\u003e Ethernet VPNs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMulticast\u003c\/td\u003e\n\u003ctd\u003eUp to 256,000 IPv4 multicast routes\u003cbr\u003e Up to 256,000 IPv6 multicast routes\u003cbr\u003e Internet Group Management Protocol (IGMP) v1\/v2\/v3\u003cbr\u003e IGMP snooping\u003cbr\u003e MLD snooping\u003cbr\u003e Protocol Independent Multicast PIM-SM, PIM-SSM, PIM-DM\u003cbr\u003e Multicast Source Discovery Protocol (MSDP)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFirewall filters\u003c\/td\u003e\n\u003ctd\u003ePort ACLs\u003cbr\u003e VLAN ACLs\u003cbr\u003e Router ACLs\u003cbr\u003e Control plane denial-of-service (DoS) protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eQuality of service (QoS)\u003c\/td\u003e\n\u003ctd\u003e16,000 policers per chassis\u003cbr\u003e 8 egress queues per port\u003cbr\u003e Weighted random early detection (WRED) scheduling\u003cbr\u003e Weighted round-robin (WRR) queuing\u003cbr\u003e Strict priority queuing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVirtualization\u003c\/td\u003e\n\u003ctd\u003eIntegration with Juniper Networks Contrail\u003cbr\u003e Integration with VMware NSX SDN controllers\u003cbr\u003e Network virtualization protocols such as Virtual eXtensible LAN (VXLAN) and Open vSwitch Database (OVSDB)\u003cbr\u003e VXLAN Layer 2 and Layer 3 Gateway\u003cbr\u003e EVPN\u003cbr\u003e EVPN Multihoming (EVPN Switch Interface – Link aggregation)\u003cbr\u003e EVPN VXLAN L2 and L3 gateway\u003cbr\u003e Virtual Private LAN Service (VPLS) for Data Center Interconnect\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManagement\u003c\/td\u003e\n\u003ctd\u003eJunos OS command-line interface (CLI)\u003cbr\u003e Junos XML management protocol\u003cbr\u003e SNMP v1\/v2\/v3\u003cbr\u003e RADIUS\u003cbr\u003e TACACS+\u003cbr\u003e Extensive MIB support\u003cbr\u003e Firewall-based port mirroring\u003cbr\u003e Link Layer Discovery Protocol (LLDP)\u003cbr\u003e Advanced Insight Solutions (AIS)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating temperature\u003c\/td\u003e\n\u003ctd\u003e32° to 104° F (0° to 40° C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage temperature\u003c\/td\u003e\n\u003ctd\u003e-40° to 158° F (-40° to 70° C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating altitude\u003c\/td\u003e\n\u003ctd\u003eUp to 10,000 ft (3,048 m)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeismic\u003c\/td\u003e\n\u003ctd\u003eDesigned to meet GR-63, Zone 4 earthquake requirements\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative humidity operating\u003c\/td\u003e\n\u003ctd\u003e5% to 90% (noncondensing)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative humidity non-operating\u003c\/td\u003e\n\u003ctd\u003e5 to 95% (noncondensing)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIEEE Compliance\u003c\/td\u003e\n\u003ctd\u003eIEEE 802.1AB: Link Layer Discovery Protocol (LLDP)\u003cbr\u003e IEEE 802.1D-2004: Spanning Tree Protocol (STP)\u003cbr\u003e IEEE 802.1p: Class-of-service (CoS) prioritization\u003cbr\u003e IEEE 802.1Q: Virtual Bridged Local Area Networks\u003cbr\u003e IEEE 802.1s: Multiple Spanning Tree Protocol (MSTP)\u003cbr\u003e IEEE 802.1w: Rapid Spanning Tree Protocol (RSTP)\u003cbr\u003e IEEE 802.3: 10BASE-T\u003cbr\u003e IEEE 802.3u: 100BASE-T\u003cbr\u003e IEEE 802.3ab: 1000BASE-T\u003cbr\u003e IEEE 802.3z: 1000BASE-X\u003cbr\u003e IEEE 802.3ae: 10-Gigabit Ethernet\u003cbr\u003e IEEE 802.3ba: 40-Gigabit\/100-Gigabit Ethernet\u003cbr\u003e IEEE 802.3ah: Operation, Administration, and Maintenance (OAM)\u003cbr\u003e IEEE 802.3ad: Link Aggregation Control Protocol (LACP)\u003cbr\u003e IEEE 802.1ae: Media Access Control Security\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRFC Compliance\u003c\/td\u003e\n\u003ctd\u003eRFC 768: UDP\u003cbr\u003e RFC 783: Trivial File Transfer Protocol (TFTP)\u003cbr\u003e RFC 791: IP\u003cbr\u003e RFC 792: Internet Control Message Protocol (ICMP)\u003cbr\u003e RFC 793: TCP\u003cbr\u003e RFC 826: ARP\u003cbr\u003e RFC 854: Telnet client and server\u003cbr\u003e RFC 894: IP over Ethernet\u003cbr\u003e RFC 903: Reverse Address Resolution Protocol (RARP)\u003cbr\u003e RFC 906: TFTP Bootstrap\u003cbr\u003e RFC 951, 1542: BootP\u003cbr\u003e RFC 1027: Proxy ARP\u003cbr\u003e RFC 1058: RIP v1\u003cbr\u003e RFC 1112: IGMP v1\u003cbr\u003e RFC 1122: Host Requirements\u003cbr\u003e RFC 1195: Use of Open Systems Interconnection (OSI) IS-IS for Routing in TCP\/IP and Dual Environments (TCP\/IP transport only)\u003cbr\u003e RFC 1256: IPv4 ICMP Router Discovery Protocol (IRDP)\u003cbr\u003e RFC 1492: TACACS+\u003cbr\u003e RFC 1519: Classless Interdomain Routing (CIDR)\u003cbr\u003e RFC 1587: OSPF NSSA Option\u003cbr\u003e RFC 1591: Domain Name System (DNS)\u003cbr\u003e RFC 1745: BGP4\/IDRP for IP-OSPF Interaction\u003cbr\u003e RFC 1765: OSPF Database Overflow\u003cbr\u003e RFC 1771: Border Gateway Protocol 4\u003cbr\u003e RFC 1772: Application of the Border Gateway Protocol in the Internet\u003cbr\u003e RFC 1812: Requirements for IP Version 4 Routers\u003cbr\u003e RFC 1965: Autonomous System Confederations for BGP\u003cbr\u003e RFC 1981: Path maximum transmission unit (MTU) Discovery for IPv6\u003cbr\u003e RFC 1997: BGP Communities Attribute\u003cbr\u003e RFC 2030: Simple Network Time Protocol (SNTP)\u003cbr\u003e RFC 2068: HTTP server\u003cbr\u003e RFC 2080: RIPng for IPv6\u003cbr\u003e RFC 2081: RIPng Protocol Applicability Statement\u003cbr\u003e RFC 2131: BOOTP\/Dynamic Host Configuration Protocol (DHCP) relay agent* and DHCP server*\u003cbr\u003e RFC 2138: RADIUS Authentication\u003cbr\u003e RFC 2139: RADIUS Accounting\u003cbr\u003e RFC 2154: OSPF with Digital Signatures (password, Message Digest 5)\u003cbr\u003e RFC 2236: IGMP v2\u003cbr\u003e RFC 2267: Network Ingress Filtering\u003cbr\u003e RFC 2270: BGP-4 Dedicated autonomous system (AS) for Sites\/Single Provider\u003cbr\u003e RFC 2283: Multiprotocol Extensions for BGP-4\u003cbr\u003e RFC 2328: OSPF v2 (Edge mode)\u003cbr\u003e RFC 2338: VRRP*\u003cbr\u003e RFC 2362: PIM-SM (Edge mode)\u003cbr\u003e RFC 2370: OSPF Opaque LSA Option\u003cbr\u003e RFC 2373: IPv6 Addressing Architecture\u003cbr\u003e RFC 2375: IPv6 Multicast Address Assignments\u003cbr\u003e RFC 2385: TCP MD5 Authentication for BGPv4\u003cbr\u003e RFC 2439: BGP Route Flap Damping\u003cbr\u003e RFC 2453: RIP v2\u003cbr\u003e RFC 2460: Internet Protocol, v6 (IPv6) specification\u003cbr\u003e RFC 2461: Neighbor Discovery for IP Version 6 (IPv6)\u003cbr\u003e RFC 2462: IPv6 Stateless Address Autoconfiguration\u003cbr\u003e RFC 2463: ICMPv6\u003cbr\u003e RFC 2464: Transmission of IPv6 Packets over Ethernet Networks\u003cbr\u003e RFC 2474: DiffServ Precedence, including 8 queues\/port\u003cbr\u003e RFC 2475: DiffServ Core and Edge Router Functions\u003cbr\u003e RFC 2526: Reserved IPv6 Subnet Anycast Addresses\u003cbr\u003e RFC 2545: Use of BGP-4 Multiprotocol Extensions for IPv6 Interdomain Routing\u003cbr\u003e RFC 2547: BGP\/MPLS VPNs\u003cbr\u003e RFC 2597: DiffServ Assured Forwarding (AF)\u003cbr\u003e RFC 2598: DiffServ Expedited Forwarding (EF)\u003cbr\u003e RFC 2710: Multicast Listener Discovery (MLD) for IPv6\u003cbr\u003e RFC 2711: IPv6 Router Alert Option\u003cbr\u003e RFC 2740: OSPF for IPv6\u003cbr\u003e RFC 2796: BGP Route Reflection (supersedes RFC 1966)\u003cbr\u003e RFC 2796: Route Reflection\u003cbr\u003e RFC 2858: Multiprotocol Extensions for BGP-4\u003cbr\u003e RFC 2893: Transition Mechanisms for IPv6 Hosts and Routers\u003cbr\u003e RFC 2918: Route Refresh Capability for BGP-4\u003cbr\u003e RFC 3031: Multiprotocol Label Switching Architecture\u003cbr\u003e RFC 3032: MPLS Label Stack Encoding\u003cbr\u003e RFC 3036: LDP Specification\u003cbr\u003e RFC 3065: Autonomous System Confederations for BGP\u003cbr\u003e RFC 3176 sFlow\u003cbr\u003e RFC 3215: LDP State Machine\u003cbr\u003e RFC 3306: Unicast-Prefix-based IPv6 Multicast Addresses\u003cbr\u003e RFC 3376: IGMP v3\u003cbr\u003e RFC 3392: Capabilities Advertisement with BGP-4\u003cbr\u003e RFC 3446: Anycast Rendevous Point (RP) Mechanism using PIM and MSDP\u003cbr\u003e RFC 3478: Graceful Restart for Label Distribution Protocol\u003cbr\u003e RFC 3484: Default Address Selection for IPv6\u003cbr\u003e RFC 3513: Internet Protocol Version 6 (IPv6) Addressing\u003cbr\u003e RFC 3569: PIM-SSM PIM Source Specific Multicast\u003cbr\u003e RFC 3587: IPv6 Global Unicast Address Format\u003cbr\u003e RFC 3618: Multicast Source Discovery Protocol (MSDP)\u003cbr\u003e RFC 3623: OSPF Graceful Restart\u003cbr\u003e RFC 3768: Virtual Router Redundancy Protocol (VRRP)*\u003cbr\u003e RFC 3810: Multicast Listener Discovery Version 2 (MLDv2) for IP\u003cbr\u003e RFC 3973: PIM-Dense Mode\u003cbr\u003e RFC 4213: Basic Transition Mechanisms for IPv6 Hosts and Routers\u003cbr\u003e RFC 4291: IPv6 Addressing Architecture\u003cbr\u003e RFC 4360: BGP Extended Communities Attribute\u003cbr\u003e RFC 4364: BGP\/MPLS IP Virtual Private Networks (VPNs)\u003cbr\u003e RFC 4443: ICMPv6 for the IPv6 specification\u003cbr\u003e RFC 4486: Sub codes for BGP Cease Notification message\u003cbr\u003e RFC 4552: Authentication\/Confidentiality for OSPFv3\u003cbr\u003e RFC 4604: Using Internet Group Management Protocol Version 3 (IGMPv3)\u003cbr\u003e RFC 4724: Graceful Restart Mechanism for BGP\u003cbr\u003e RFC 4761: Virtual Private LAN Service (VPLS) using BGP for auto-discovery and signaling\u003cbr\u003e RFC 4798: Connecting IPv6 Islands over IPv4 MPLS Using IPv6 Provider Edge Routers (6PE)\u003cbr\u003e RFC 4861: Neighbor Discovery for IPv6\u003cbr\u003e RFC 4862: IPv6 Stateless Address Autoconfiguration\u003cbr\u003e RFC 5095: Deprecation of Type 0 Routing Headers in IPv6\u003cbr\u003e RFC 5286, Basic Specification for IP Fast Reroute: Loop-Free Alternates\u003cbr\u003e RFC 5306: Restart Signaling for IS-IS\u003cbr\u003e RFC 5308: Routing IPv6 with IS-IS\u003cbr\u003e RFC 5340: OSPF for IPv6\u003cbr\u003e Draft-ietf-bfd-base-09.txt: Bidirectional Forwarding Detection\u003cbr\u003e Draft-ietf-l2vpn-evpn-00.txt: BGP MPLS-based Ethernet VPN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eServices and Manageability\u003c\/td\u003e\n\u003ctd\u003eVirtual eXtensible Local Area Network (VXLAN)\u003cbr\u003e REST API\u003cbr\u003e NETCONF sessions over outbound HTTPS\u003cbr\u003e Juniper Extension Toolkit (JET)\u003cbr\u003e OpenFlow v1.3\u003cbr\u003e Junos OS CLI\u003cbr\u003e Out-of-band management: Serial; 10\/100\/1000BASE-T Ethernet\u003cbr\u003e ASCII configuration file\u003cbr\u003e Rescue configuration\u003cbr\u003e Configuration rollback\u003cbr\u003e Image rollback\u003cbr\u003e SNMP: v1, v2c, v3\u003cbr\u003e RMON (RFC 2819): Groups 1, 2, 3, 9\u003cbr\u003e Network Time Protocol (NTP)\u003cbr\u003e DHCP server\u003cbr\u003e DHCP relay with Option 82\u003cbr\u003e RADIUS\u003cbr\u003e TACACS+\u003cbr\u003e SSHv2\u003cbr\u003e Secure copy\u003cbr\u003e DNS resolver\u003cbr\u003e Syslog logging\u003cbr\u003e Environment monitoring\u003cbr\u003e Temperature sensor\u003cbr\u003e Configuration backup via FTP\/secure copy\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNetwork Management—MIB Support\u003c\/td\u003e\n\u003ctd\u003eJ-Flow\u003cbr\u003e RFC 1155: Structure of Management Information (SMI)\u003cbr\u003e RFC 1157: SNMPv1\u003cbr\u003e RFC 1212, RFC 1213, RFC 1215: MIB-II, Ethernet-like MIB, and traps\u003cbr\u003e RFC 1657: BGP-4 MIB\u003cbr\u003e RFC 1724: RIPv2 MIB\u003cbr\u003e RFC 1850: OSPFv2 MIB\u003cbr\u003e RFC 1901: Introduction to Community-based SNMPv2\u003cbr\u003e RFC 1902: Structure of Management Information for Version 2 of the Simple Network Management Protocol (SNMPv2)\u003cbr\u003e RFC 1905, RFC 1907: SNMP v2c, SMIv2, and Revised MIB-II\u003cbr\u003e RFC 2011: SNMPv2 for IP using SMIv2\u003cbr\u003e RFC 2012: SNMPv2 for transmission control protocol using SMIv2\u003cbr\u003e RFC 2013: SNMPv2 for user datagram protocol using SMIv2\u003cbr\u003e RFC 2096: IPv4 Forwarding Table MIB\u003cbr\u003e RFC 2287: System Application Packages MIB\u003cbr\u003e RFC 2465: Management Information Base for IP Version 6\u003cbr\u003e RFC 2570–2575: SNMPv3, user-based security, encryption, and authentication\u003cbr\u003e RFC 2576: Coexistence between SNMP Version 1, Version 2, and Version 3\u003cbr\u003e RFC 2578: SNMP Structure of Management Information MIB\u003cbr\u003e RFC 2579: SNMP Textual Conventions for SMIv2\u003cbr\u003e RFC 2665: Ethernet-like interface MIB\u003cbr\u003e RFC 2787: VRRP MIB\u003cbr\u003e RFC 2819: RMON MIB\u003cbr\u003e RFC 2863: Interface Group MIB\u003cbr\u003e RFC 2863: Interface MIB\u003cbr\u003e RFC 2922: LLDP MIB\u003cbr\u003e RFC 2925: Ping\/Traceroute MIB\u003cbr\u003e RFC 2932: IPv4 Multicast MIB\u003cbr\u003e RFC 3413: SNMP Application MIB\u003cbr\u003e RFC 3826: The Advanced Encryption Standard (AES) Cipher Algorithm in the SNMP\u003cbr\u003e RFC 4188: STP and Extensions MIB\u003cbr\u003e RFC 4363: Definitions of Managed Objects for Bridges with traffic classes, multicast filtering, and VLAN extensions\u003cbr\u003e Draft-ietf-idr-bgp4-mibv2-02.txt: Enhanced BGP-4 MIB\u003cbr\u003e Draft-ietf-isis-wg-mib-07\u003cbr\u003e Draft-reeder-snmpv3-usm-3desede-00\u003cbr\u003e Draft-ietf-idmr-igmp-mib-13\u003cbr\u003e Draft-ietf-idmr-pim-mib-09\u003cbr\u003e Draft-ietf-bfd-mib-02.txt\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety\u003c\/td\u003e\n\u003ctd\u003eCAN\/CSA-22.2 No. 60950-00\/UL 1950 Third Edition, Safety of Information Technology Equipment\u003cbr\u003e EN 60825-1 Safety of Laser Products—Part 1: Equipment Classification, Requirements, and User’s Guide\u003cbr\u003e EN 60950 Safety of Information Technology Equipment\u003cbr\u003e IEC 60950-1 (2001) Safety of Information Technology Equipment (with country deviations)\u003cbr\u003e EN 60825-1 +A1+A2 (1994) Safety of Laser Products—Part 1: Equipment Classification\u003cbr\u003e EN 60825-2 (2000) Safety of Laser Products—Part 2: Safety of Optical Fiber Comm. Systems\u003cbr\u003e C-UL to CAN\/CSA 22.2 No.60950-1 (Second Edition)\u003cbr\u003e TUV\/GS to EN 60950-1, Amendment A1-A4, A11\u003cbr\u003e CE-IEC60950-1, all country deviations\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEMC\u003c\/td\u003e\n\u003ctd\u003eAS\/NZS CISPR22:2009\u003cbr\u003e EN 55022 2006+A1:2007 European Radiated Emissions\u003cbr\u003e FCC 47CFR , Part 15 Class A (2009) USA Radiated Emissions\u003cbr\u003e VCCI-V-3\/2009.04 and V-4\/2009.04 Japanese Radiated Emissions\u003cbr\u003e BSMI CNS 13438 and NCC C6357 Taiwan Radiated Emissions\u003cbr\u003e EN 300 386 V1.5.1 Telecom Network Equipment - EMC requirements\u003cbr\u003e ICES-003 Issue 4, Feb 2004 Canada Radiated Emissions\u003cbr\u003e CISPR 24:1997\/A1:2001\/A2:2002 IT Equipment Immunity Characteristics\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eImmunity\u003c\/td\u003e\n\u003ctd\u003eEN 55024:1998\/A1:2001\/A2:2003 Information Technology Equipment Immunity Characteristics\u003cbr\u003e EN-61000-3-2 (2006) Power Line Harmonics\u003cbr\u003e EN-61000-3-3 +A1 +A2 +A3 (1995) Power Line Voltage Fluctuations\u003cbr\u003e EN-61000-4-2 +A1 +A2 (1995) Electrostatic Discharge\u003cbr\u003e EN-61000-4-3 +A1+A2 (2002) Radiated Immunity\u003cbr\u003e EN-61000-4-4 (2004) Electrical Fast Transients\u003cbr\u003e EN-61000-4-5 (2006) Surge\u003cbr\u003e EN-61000-4-6 (2007) Immunity to Conducted Disturbances\u003cbr\u003e EN-61000-4-11 (2004) Voltage Dips and Sags\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNetwork Equipment Building System (NEBS)\u003c\/td\u003e\n\u003ctd\u003eSR-3580 NEBS Criteria Levels (Level 3 Compliance)\u003cbr\u003e GR-63-Core: NEBS, Physical Protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironmental\u003c\/td\u003e\n\u003ctd\u003eReduction of Hazardous Substances (ROHS) 5\/6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTelco\u003c\/td\u003e\n\u003ctd\u003eCommon Language Equipment Identifier (CLEI) code\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eCompatible Accessories\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003eLine Cards\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEX9200-15C\u003c\/td\u003e\n\u003ctd\u003e15x 100GbE\/40GbE line card with MACsec AES-256 for EX9200\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEX9200-40XS\u003c\/td\u003e\n\u003ctd\u003e40-port 10GbE SFP+ line card supporting MACsec AES-256 (requires SFL software license for activation); requires SFP+ optics sold separately\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEX9200-12QS\u003c\/td\u003e\n\u003ctd\u003e12-port 40GbE QSFP+ or 4-port 100GbE QSFP28 combo line card; requires optics sold separately\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEX9200-MPC\u003c\/td\u003e\n\u003ctd\u003eEX9200 Modular Port Concentrator (MPC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEX9200-20F-MIC\u003c\/td\u003e\n\u003ctd\u003eEX9200 20-port GBASE-X (half-slot) Modular Interface Card (MIC) supporting MACsec AES-128 (requires SFL software license for activation); requires EX9200-MPC (ordered separately)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEX9200-10XS-MIC\u003c\/td\u003e\n\u003ctd\u003eEX9200 10-port 10GBASE-X (half-slot) Modular Interface Card (MIC); requires EX9200-MPC (ordered separately)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce\u003e\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Juniper","offers":[{"title":"Default Title","offer_id":48013260095705,"sku":"EX9204-RED3B-AC-NEW","price":48726.77,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0016\/5327\/6707\/files\/ex9204_74b2b268-b53d-42bb-a527-c5663a816d82.jpg?v=1771852839","url":"https:\/\/www.aloinfousa.com\/pt-br\/products\/juniper-ex9204-red3b-ac-chassis-hmbvd","provider":"aloinfousa.com","version":"1.0","type":"link"}