{"product_id":"juniper-qfx5220-32cd-afi-switch-lv06w","title":"Juniper QFX5220-32CD-AFI Switch","description":"\u003cspan\u003eThe QFX5200 line of access switches is ideally suited for leaf deployments in next-generation IP fabrics. It features line-rate, high-density SFP28\/QSFP+\/QSFP28 ports that support 10GbE, 25GbE, 40GbE, 50GbE, and 100GbE connections. Offering an advanced L2, L3, and MPLS feature set, network operators can use the QFX5200 to build large, high-density IP fabrics that support upgrades to 25GbE servers, network virtualization, and intelligent traffic forwarding based on proven, Internet-scale technology. The QFX5200 also supports a version of Junos OS software in which control plane and data plane processes and functions run in parallel, maximizing utilization of the high-performance quad-core CPU.\u003c\/span\u003e\n\u003ch3\u003eProduct Details\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eProperties\u003c\/td\u003e\n\u003ctd\u003eJuniper QFX5210-32CD-AFI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDescription\u003c\/td\u003e\n\u003ctd\u003eQFX5220 (hardware with base software), 32 QSFP-DD\/QSFP+\/QSFP28 ports, redundant fans, 2 AC power supplies, back-to-front airflow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Family\u003c\/td\u003e\n\u003ctd\u003eQFX5220 Series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eEthernet Switch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (HxWxD) Inches\u003c\/td\u003e\n\u003ctd\u003e17.26 x 1.72 x 21.1 in.\u003cbr\u003e (43.8 x 4.3 x 53.59 cm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRack units\u003c\/td\u003e\n\u003ctd\u003e1 U\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e24.5 lb (11.11 kg) with power supplies and fans installed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating system\u003c\/td\u003e\n\u003ctd\u003eJunos OS Evolved\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRecommended Software Version\u003c\/td\u003e\n\u003ctd\u003eJunos OS Evolved 19.2R1 and Later\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003eDeployment Options for QFX5210-64C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePort Combinations\u003c\/td\u003e\n\u003ctd\u003eDeployment\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e64x100GbE\u003c\/td\u003e\n\u003ctd\u003eSpine\/leaf\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e96x25GbE + 8x100GbE\u003c\/td\u003e\n\u003ctd\u003e 25GbE access\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003eInterface Options\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePort density\u003c\/td\u003e\n\u003ctd\u003e 32 ports of QSFP56-DD 400GbE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSFP+\/SFP28\u003c\/td\u003e\n\u003ctd\u003e2 SFP+ transceiver ports for in-band network management\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCooling\u003c\/td\u003e\n\u003ctd\u003eFRUs-to-ports (AFI) cooling\u003cbr\u003e Redundant (5x2+1)+1 hot-pluggable fan modules with variable speed to minimize power draw\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower\u003c\/td\u003e\n\u003ctd\u003eRedundant (1+1) hot-pluggable 1600 W AC power supplies (2n)\u003cbr\u003e 115-240 V single phase AC power\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003eMaximum Thermal Output\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum power draw \u003c\/td\u003e\n\u003ctd\u003e115-127 V: 973 W; 220-240 V: 958 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTypical power draw \u003c\/td\u003e\n\u003ctd\u003e115-127 V: 730 W; 220-240 V: 775 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSpecifications\u003c\/td\u003e\n\u003ctd\u003eQFX5220-32CD-AFI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCPU\u003c\/td\u003e\n\u003ctd\u003eIntel Xeon D-1518\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem throughput\u003c\/td\u003e\n\u003ctd\u003eUp to 25.6 Tbps (bidirectional)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eForwarding capacity\u003c\/td\u003e\n\u003ctd\u003e8 billion packets per second\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTotal packet buffer\u003c\/td\u003e\n\u003ctd\u003e64 MB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMAC addresses per system\u003c\/td\u003e\n\u003ctd\u003e8192\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVLAN Ids\u003c\/td\u003e\n\u003ctd\u003e3968\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of link aggregation groups (LAGs)\u003c\/td\u003e\n\u003ctd\u003e128\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of ports per LAG\u003c\/td\u003e\n\u003ctd\u003e64\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFirewall filters\u003c\/td\u003e\n\u003ctd\u003eIngress: 768 Routed ACL (RACL), VLAN ACL (VACL), and Port ACL (PACL) rules\u003cbr\u003e Egress: 2558  RACL; 512 VACL and PACL rules\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIPv4 unicast routes\u003c\/td\u003e\n\u003ctd\u003e380,000 prefixes; 380,000 host routes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIPv6 unicast routes\u003c\/td\u003e\n\u003ctd\u003e130,000 prefixes; 130,000 host routes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAddress Resolution Protocol (ARP) entries\u003c\/td\u003e\n\u003ctd\u003e32,000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGeneric routing encapsulation (GRE) tunnels\u003c\/td\u003e\n\u003ctd\u003e2000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMPLS labels\u003c\/td\u003e\n\u003ctd\u003e16,000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eJumbo frame\u003c\/td\u003e\n\u003ctd\u003e9,216 bytes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTraffic mirroring\u003c\/td\u003e\n\u003ctd\u003e- Mirroring destination ports per switch: 4\u003cbr\u003e - Maximum number of mirroring sessions: 4\u003cbr\u003e - Mirroring destination VLANs per switch: 4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003eSoftware Specifications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLayer 2 Features\u003cbr\u003e (*Reserved for future release)\u003c\/td\u003e\n\u003ctd\u003eSTPIEEE 802.1D (802.1D-2004)*\u003cbr\u003e Rapid Spanning Tree Protocol (RSTP) (IEEE 802.1w); MSTP (IEEE 802.1s)*\u003cbr\u003e Bridge protocol data unit (BPDU) protect*\u003cbr\u003e Loop protect*\u003cbr\u003e Root protect*\u003cbr\u003e RSTP and VSTP running concurrently*\u003cbr\u003e VLANIEEE 802.1Q VLAN trunking\u003cbr\u003e Routed VLAN interface (RVI)\u003cbr\u003e Port-based VLAN\u003cbr\u003e MAC address filtering*\u003cbr\u003e Static MAC address assignment for interface\u003cbr\u003e MAC learning disable\u003cbr\u003e Link Aggregation and Link Aggregation Control Protocol (LACP) (IEEE 802.3ad)\u003cbr\u003e IEEE 802.1AB Link Layer Discovery Protocol (LLDP)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLayer 3 Features\u003cbr\u003e (*Reserved for future release)\u003c\/td\u003e\n\u003ctd\u003eStatic routing\u003cbr\u003e OSPF v1\/v2\u003cbr\u003e OSPF v3\u003cbr\u003e Filter-based forwarding\u003cbr\u003e Virtual Router Redundancy Protocol (VRRP)*\u003cbr\u003e IPv6\u003cbr\u003e Virtual routers\u003cbr\u003e Loop-free alternate (LFA)\u003cbr\u003e BGP (Advanced Services or Premium Services license)\u003cbr\u003e IS-IS (Advanced Services or Premium Services license)\u003cbr\u003e Dynamic Host Configuration Protocol (DHCP) v4\/v6 relay\u003cbr\u003e VR-aware DHCP\u003cbr\u003e IPv4\/IPv6 over GRE tunnels (interface-based with decap\/encap only)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMulticast Features\u003cbr\u003e (*Reserved for future release)\u003c\/td\u003e\n\u003ctd\u003eInternet Group Management Protocol (IGMP) v1\/v2\u003cbr\u003e Multicast Listener Discovery (MLD) v1\/v2\u003cbr\u003e IGMP proxy, querier\u003cbr\u003e IGMP v1\/v2\/v3 snooping\u003cbr\u003e Intersubnet multicast using IRB interface\u003cbr\u003e MLD snooping\u003cbr\u003e Protocol Independent Multicast PIM-SM, PIM-SSM, PIM-DM, PIM-Bidir*\u003cbr\u003e Multicast Source Discovery Protocol (MSDP)*\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLink Aggregation\u003c\/td\u003e\n\u003ctd\u003eLAG load sharing algorithmbridged or routed (unicast or multicast) traffic:\u003cbr\u003e -IP: Session Initiation Protocol (SIP), Dynamic Internet Protocol (DIP), TCP\/UDP source port, TCP\/UDP destination port\u003cbr\u003e -L2 and non-IP: MAC SA, MAC DA, Ether type, VLAN ID, source port\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eQuality of Service (QoS)\u003c\/td\u003e\n\u003ctd\u003eL2 and L3 QoS: Classification, rewrite, queuing\u003cbr\u003e Rate limiting:\u003cbr\u003e -Ingress policing: 1 rate 2 color, 2 rate 3 color\u003cbr\u003e -Egress policing: Policer, policer mark down action\u003cbr\u003e -Egress shaping: Per queue, per port\u003cbr\u003e 10 hardware queues per port (8 unicast and 2 multicast)\u003cbr\u003e Strict priority queuing (LLQ), shaped-deficit weighted round-robin (SDWRR), weighted random early detection (WRED)\u003cbr\u003e 802.1p remarking\u003cbr\u003e Layer 2 classification criteria: Interface, MAC address, Ethertype, 802.1p, VLAN\u003cbr\u003e Congestion avoidance capabilities: WRED, ECN\u003cbr\u003e Trust IEEE 802.1p (ingress)\u003cbr\u003e Remarking of bridged packets\u003cbr\u003e Configurable shared buffer and buffer monitoring\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSecurity and Filters\u003cbr\u003e (*Reserved for future release)\u003c\/td\u003e\n\u003ctd\u003eSecure interface login and password\u003cbr\u003e RADIUS\u003cbr\u003e TACACS+\u003cbr\u003e Ingress and egress filters: Allow and deny, port filters, VLAN filters, and routed filters, including management port filters, loopback filters for control plane protection\u003cbr\u003e Filter actions: Logging, system logging, reject, mirror to an interface, counters, assign forwarding class, permit, drop, police, mark\u003cbr\u003e SSH v1, v2\u003cbr\u003e Static ARP support\u003cbr\u003e Storm control, port error disable, and autorecovery*\u003cbr\u003e Control plane denial-of-service (DoS) protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eData Center Bridging (DCB)\u003cbr\u003e (*Reserved for future release)\u003c\/td\u003e\n\u003ctd\u003ePriority-based flow control (PFC)IEEE 802.1Qbb\u003cbr\u003e Data Center Bridging Exchange Protocol (DCBX)*\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHigh Availability\u003cbr\u003e (*Reserved for future release)\u003c\/td\u003e\n\u003ctd\u003eSub-second Bidirectional Forwarding Detection (BFD)\u003cbr\u003e Uplink failure detection (UFD)*\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMPLS (Advanced Services License)\u003cbr\u003e (*Reserved for future release)\u003c\/td\u003e\n\u003ctd\u003eStatic label-switched paths (LSPs)\u003cbr\u003e RSVP-based signaling of LSPs\u003cbr\u003e LDP-based signaling of LSPs\u003cbr\u003e LDP tunneling (LDP over RSVP)\u003cbr\u003e MPLS class of service (CoS)*\u003cbr\u003e MPLS access control list (ACL)\/policers*\u003cbr\u003e MPLS LSR support\u003cbr\u003e IPv4 L3 VPN (RFC 2547, 4364)\u003cbr\u003e MPLS fast reroute (FRR)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVisibility and Analytics\u003c\/td\u003e\n\u003ctd\u003eSwitched Port Analyzer (SPAN)\u003cbr\u003e Remote SPAN (RSPAN)\u003cbr\u003e Encapsulated Remote SPAN (ERSPAN)\u003cbr\u003e SFlow v5\u003cbr\u003e Junos Telemetry Interface\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDevice Management and Operations\u003cbr\u003e (*Reserved for future release)\u003c\/td\u003e\n\u003ctd\u003eContrail Networking*\u003cbr\u003e Role-based CLI management and access\u003cbr\u003e CLI via console, telnet, or SSH\u003cbr\u003e Extended ping and traceroute\u003cbr\u003e Junos OS Evolved configuration rescue and rollback\u003cbr\u003e Image rollback\u003cbr\u003e SNMP v1\/v2\/v3\u003cbr\u003e Junos OS Evolved XML management protocol\u003cbr\u003e High frequency statistics collection\u003cbr\u003e Automation and orchestration\u003cbr\u003e Zero-touch provisioning (ZTP)\u003cbr\u003e Python\u003cbr\u003e Junos OS Evolved event, commit, and OP scripts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating temperature\u003c\/td\u003e\n\u003ctd\u003e32° to 104° F (0° to 40° C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage temperature\u003c\/td\u003e\n\u003ctd\u003e-40° to 158° F (-40° to 70° C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating altitude\u003c\/td\u003e\n\u003ctd\u003eUp to 6000 feet (1828.8 meters)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative humidity operating\u003c\/td\u003e\n\u003ctd\u003e5% to 90% (noncondensing)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative humidity non-operating\u003c\/td\u003e\n\u003ctd\u003e0% to 95% (noncondensing)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeismic\u003c\/td\u003e\n\u003ctd\u003eDesigned to meet GR-63, Zone 4 earthquake requirements\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIEEE Standards\u003c\/td\u003e\n\u003ctd\u003eIEEE 802.1D\u003cbr\u003e IEEE 802.1w\u003cbr\u003e IEEE 802.1\u003cbr\u003e IEEE 802.1Q\u003cbr\u003e IEEE 802.1p\u003cbr\u003e IEEE 802.1ad\u003cbr\u003e IEEE 802.3ad\u003cbr\u003e IEEE 802.1AB\u003cbr\u003e IEEE 802.3x\u003cbr\u003e IEEE 802.1Qbb\u003cbr\u003e IEEE 802.1Qaz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eT11 Standards\u003c\/td\u003e\n\u003ctd\u003eINCITS T11 FC-BB-5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupported RFCs\u003c\/td\u003e\n\u003ctd\u003eRFC 768 UDP\u003cbr\u003e RFC 783 Trivial File Transfer Protocol (TFTP)\u003cbr\u003e RFC 791 IP\u003cbr\u003e RFC 792 ICMP\u003cbr\u003e RFC 793 TCP\u003cbr\u003e RFC 826 ARP\u003cbr\u003e RFC 854 Telnet client and server\u003cbr\u003e RFC 894 IP over Ethernet\u003cbr\u003e RFC 903 RARP\u003cbr\u003e RFC 906 TFTP Bootstrap\u003cbr\u003e RFC 951 1542 BootP\u003cbr\u003e RFC 1058 Routing Information Protocol\u003cbr\u003e RFC 1112 IGMP v1\u003cbr\u003e RFC 1122 Host requirements\u003cbr\u003e RFC 1142 OSI IS-IS Intra-domain Routing Protocol\u003cbr\u003e RFC 1256 IPv4 ICMP Router Discovery (IRDP)\u003cbr\u003e RFC 1492 TACACS+\u003cbr\u003e RFC 1519 Classless Interdomain Routing (CIDR)\u003cbr\u003e RFC 1587 OSPF not-so-stubby area (NSSA) Option\u003cbr\u003e RFC 1591 Domain Name System (DNS)\u003cbr\u003e RFC 1745 BGP4\/IDRP for IPOSPF Interaction\u003cbr\u003e RFC 1772 Application of the Border Gateway Protocol in the Internet\u003cbr\u003e RFC 1812 Requirements for IP Version 4 routers\u003cbr\u003e RFC 1997 BGP Communities Attribute\u003cbr\u003e RFC 2030 SNTP, Simple Network Time Protocol\u003cbr\u003e RFC 2068 HTTP server\u003cbr\u003e RFC 2131 BOOTP\/DHCP relay agent and Dynamic Host\u003cbr\u003e RFC 2138 RADIUS Authentication\u003cbr\u003e RFC 2139 RADIUS Accounting\u003cbr\u003e RFC 2154 OSPF w\/Digital Signatures (password, MD-5)\u003cbr\u003e RFC 2236 IGMP v2\u003cbr\u003e RFC 2267 Network ingress filtering\u003cbr\u003e RFC 2328 OSPF v2 (edge mode)\u003cbr\u003e RFC 2338 VRRP\u003cbr\u003e RFC 2362 PIM-SM (edge mode)\u003cbr\u003e RFC 2370 OSPF Opaque link-state advertisement (LSA) Option\u003cbr\u003e RFC 2385 Protection of BGP Sessions via the TCP Message Digest 5 (MD5) Signature Option\u003cbr\u003e RFC 2439 BGP Route Flap Damping\u003cbr\u003e RFC 2474 Definition of the Differentiated Services Field in the IPv4 and IPv6 Headers\u003cbr\u003e RFC 2597 Assured Forwarding PHB (per-hop behavior) Group\u003cbr\u003e RFC 2598 An Expedited Forwarding PHB\u003cbr\u003e RFC 2697 A Single Rate Three Color Marker\u003cbr\u003e RFC 2698 A Two Rate Three Color Marker\u003cbr\u003e RFC 2796 BGP Route ReflectionAn Alternative to Full Mesh IBGP\u003cbr\u003e RFC 2918 Route Refresh Capability for BGP-4\u003cbr\u003e RFC 3065 Autonomous System Confederations for BGP\u003cbr\u003e RFC 3376 IGMP v3 (source-specific multicast include mode only)\u003cbr\u003e RFC 3392 Capabilities Advertisement with BGP-4\u003cbr\u003e RFC 3446, Anycast RP\u003cbr\u003e RFC 3569 Source-specific multicast (SSM)\u003cbr\u003e RFC 3618 MSDP\u003cbr\u003e RFC 3623 Graceful OSPF Restart\u003cbr\u003e RFC 4271 Border Gateway Protocol 4 (BGP-4)\u003cbr\u003e RFC 4360 BGP Extended Communities Attribute\u003cbr\u003e RFC 4456 BGP Route Reflection: An Alternative to Full Mesh Internal BGP (IBGP)\u003cbr\u003e RFC 4486 Subcodes for BGP Cease Notification Message\u003cbr\u003e RFC 4724 Graceful Restart Mechanism for BGP\u003cbr\u003e RFC 4812 OSPF Restart Signaling\u003cbr\u003e RFC 4893 BGP Support for Four-octet AS Number Space\u003cbr\u003e RFC 5176 Dynamic Authorization Extensions to RADIUS\u003cbr\u003e RFC 5396 Textual Representation of Autonomous System (AS) Numbers\u003cbr\u003e RFC 5668 4-Octet AS Specific BGP Extended Community\u003cbr\u003e RFC 5880 Bidirectional Forwarding Detection (BFD)\u003cbr\u003e Configuration Protocol (DHCP) server\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupported MIBs\u003c\/td\u003e\n\u003ctd\u003eRFC 155 SMI\u003cbr\u003e RFC 1157 SNMPv1\u003cbr\u003e RFC 1212, RFC 1213, RFC 1215 MIB-II, Ethernet-Like MIB and TRAPs\u003cbr\u003e RFC 1850 OSPFv2 MIB\u003cbr\u003e RFC 1901 Introduction to Community-based SNMPv2\u003cbr\u003e RFC 2011 SNMPv2 for Internet protocol using SMIv2\u003cbr\u003e RFC 2012 SNMPv2 for transmission control protocol using SMIv2\u003cbr\u003e RFC 2013 SNMPv2 for user datagram protocol using SMIv2\u003cbr\u003e RFC 2233, The Interfaces Group MIB using SMIv2\u003cbr\u003e RFC 2287 System Application Packages MIB\u003cbr\u003e RFC 2570 Introduction to Version 3 of the Internet standard Network Management Framework\u003cbr\u003e RFC 2571 An Architecture for describing SNMP Management Frameworks (read-only access)\u003cbr\u003e RFC 2572 Message Processing and Dispatching for the SNMP (read-only access)\u003cbr\u003e RFC 2576 Coexistence between SNMP Version 1, Version 2, and Version 3\u003cbr\u003e RFC 2578 SNMP Structure of Management Information MIB\u003cbr\u003e RFC 2579 SNMP Textual Conventions for SMIv2\u003cbr\u003e RFC 2580 Conformance Statements for SMIv2\u003cbr\u003e RFC 2665 Ethernet-like interface MIB\u003cbr\u003e RFC 2787 VRRP MIB\u003cbr\u003e RFC 2790 Host Resources MIB\u003cbr\u003e RFC 2819 RMON MIB\u003cbr\u003e RFC 2863 Interface Group MIB\u003cbr\u003e RFC 2932 IPv4 Multicast MIB\u003cbr\u003e RFC 3410 Introduction and Applicability Statements for Internet Standard Management Framework\u003cbr\u003e RFC 3411 An architecture for describing SNMP Management Frameworks\u003cbr\u003e RFC 3412 Message Processing and Dispatching for the SNMP\u003cbr\u003e RFC 3413 Simple Network Management Protocol\u003cbr\u003e RFC 3414 User-based Security Model (USM) for SNMPv3\u003cbr\u003e RFC 3415 View-based Access Control Model (VACM) for the SNMP\u003cbr\u003e RFC 3416 Version 2 of the Protocol Operations for the SNMP\u003cbr\u003e RFC 3417 Transport Mappings for the SNMP\u003cbr\u003e RFC 3418 Management Information Base (MIB) for the SNMP\u003cbr\u003e RFC 3584 Coexistence between Version 1, Version 2, and Version 3 of the Internet Standard Network Management Framework\u003cbr\u003e RFC 3826 The Advanced Encryption Standard (AES) Cipher Algorithm in the SNMP User-based Security Model\u003cbr\u003e RFC 4188 Definitions of Managed Objects for Bridges\u003cbr\u003e RFC 4318 Definitions of Managed Objects for Bridges with Rapid Spanning Tree Protocol\u003cbr\u003e RFC 4363b Q-Bridge VLAN MIB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety\u003c\/td\u003e\n\u003ctd\u003eCAN\/CSA-C22.2 No. 60950-1 Information Technology EquipmentSafety\u003cbr\u003e UL 60950-1 Information Technology EquipmentSafety\u003cbr\u003e EN 60950-1 Information Technology EquipmentSafety\u003cbr\u003e IEC 60950-1 Information Technology EquipmentSafety (All country deviations)\u003cbr\u003e EN 60825-1 Safety of Laser ProductsPart 1: Equipment Classification\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSecurity\u003c\/td\u003e\n\u003ctd\u003eFIPS\/CC*\u003cbr\u003e TAA*\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEMC\u003c\/td\u003e\n\u003ctd\u003e47 CFR Part 15, (FCC) Class A\u003cbr\u003e ICES-003 Class A\u003cbr\u003e EN 55022\/EN 55032, Class A\u003cbr\u003e CISPR 22\/CISPR 32, Class A\u003cbr\u003e EN 55024\u003cbr\u003e CISPR 24\u003cbr\u003e EN 300 386\u003cbr\u003e VCCI Class A\u003cbr\u003e AS\/NZS CISPR 32, Class A\u003cbr\u003e KN32\/KN35\u003cbr\u003e BSMI CNS 13438, Class A\u003cbr\u003e EN 61000-3-2\u003cbr\u003e EN 61000-3-3\u003cbr\u003e ETSI\u003cbr\u003e ETSI EN 300 019: Environmental Conditions \u0026amp; Environmental Tests for Telecommunications Equipment\u003cbr\u003e ETSI EN 300 019-2-1 (2000)Storage\u003cbr\u003e ETSI EN 300 019-2-2 (1999)Transportation\u003cbr\u003e ETSI EN 300 019-2-3 (2003)Stationary Use at Weatherprotected Locations\u003cbr\u003e ETSI EN 300 019-2-4 (2003)Stationary Use at NonWeather-protected Locations\u003cbr\u003e ETS 300753 (1997)Acoustic noise emitted by telecommunications equipment\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eCompatible Accessories\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003eAccessories\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eJPSU-1600W-1UACAFI\u003c\/td\u003e\n\u003ctd\u003eQFX5220-32CD-AFI 1 U AC power supply unit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eQFX5220-32CD-FANAI\u003c\/td\u003e\n\u003ctd\u003eAirflow in (AFI) back-to-front airflow fans for QFX5220-32CD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eQFX5220-32CD-4PRMK\u003c\/td\u003e\n\u003ctd\u003e4-Post Rack Mount Kit for QFX5220-32CD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003eSoftware Licenses SKUs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eS-QFX5K-C3-A1-X (X=3,5)\u003c\/td\u003e\n\u003ctd\u003eBase L3 Software Subscription (X Years; X=3,5) License for QFX5220-32CD\/QFX5220-128C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eS-QFX5K-C3-A2-X (X=3,5)\u003c\/td\u003e\n\u003ctd\u003eAdvanced Software Subscription (X Years; X=3,5) License for QFX5220-32CD\/QFX5220-128C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eS-QFX5K-C3-P1-X (X=3,5)\u003c\/td\u003e\n\u003ctd\u003ePremium Software Subscription (X Years; X=3,5) License for QFX5220-32CD\/QFX5220-128C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003eOptics and Transceivers\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eQDD-400G-DAC-1M\u003c\/td\u003e\n\u003ctd\u003eQSFP56-DD 400GbE DAC 1 M\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eQDD-400G-DAC-2P5M\u003c\/td\u003e\n\u003ctd\u003eQSFP56-DD 400GbE DAC 2.5 M\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eQDD-4x100G-FR\u003c\/td\u003e\n\u003ctd\u003eQSFP-DD 4x100GBASE-FR breakout 1310 nm PAM4 transceiver module, 2 km reach\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eQDD-400G-DR4\u003c\/td\u003e\n\u003ctd\u003eQSFP-DD 400GBASE-DR4 \/ 4x100GBASE-DR 1310 nm PAM4 transceiver module, 500 m reach\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eQDD-400G-FR4\u003c\/td\u003e\n\u003ctd\u003eQSFP-DD 400GBASE-FR4 1310 nm PAM4 transceiver module, 2 km reach\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eQDD-400G-AOC-XM\u003c\/td\u003e\n\u003ctd\u003e400GbE QSFP56-DD active optical cable of XM (X=1,3,5,7,10,15,20,30)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eJNP-100G-4x25G-1M\u003c\/td\u003e\n\u003ctd\u003e100GbE QSFP28 to 4x25GbE SFP28 passive direct attach copper breakout cable, length: 1 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eJNP-100G-4x25G-3M\u003c\/td\u003e\n\u003ctd\u003e100GbE QSFP28 to 4x25G SFP28 passive direct attach copper breakout cable, length: 3 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eJNP-QSFP-100G-BXSR*\u003c\/td\u003e\n\u003ctd\u003e100GbE SR-bidirectional QSFP transceiver, LC, 100 M, OM4 multimode fiber-optic (MMF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Juniper","offers":[{"title":"Default Title","offer_id":48013251870937,"sku":"QFX5220-32CD-AFI-NEW","price":59755.68,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0016\/5327\/6707\/files\/QFX5220-32CD_3f08c7b6-bef9-4a23-b5d3-957ca25a348b.jpg?v=1771852693","url":"https:\/\/www.aloinfousa.com\/pt-br\/products\/juniper-qfx5220-32cd-afi-switch-lv06w","provider":"aloinfousa.com","version":"1.0","type":"link"}