{"product_id":"dell-poweredge-r240-server-wy9oy","title":"Dell PowerEdge R240 Server","description":"\u003cdiv class=\"head-content-set-outer\"\u003e\n\u003ch2 class=\"Dell_PowerEdge_R630_Specifications\"\u003eour Dell PowerEdge R240 Specifications\u003c\/h2\u003e\n\u003c!-- Chassis Section Order 1 --\u003e\n\u003cdiv class=\"head-content-set\"\u003e\n\u003ch3\u003eChassis\u003c\/h3\u003e\n\u003cdiv class=\"head-content-set-content\"\u003e\n\u003cp\u003eThe Dell PowerEdge R240 server is a budget-friendly server that can handle demanding workloads. The R240 is designed for small businesses and service providers. The PowerEdge R240 comes in two possible chassis options: 2 Bay LFF cabled and 4 Bay LFF Hot swap.\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003e2 Bay LFF Cabled\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003eThe 2 Bay LFF Cabled chassis for the PowerEdge R240 supports up to two 3.5\" SAS\/SATA drives. 2.5\" HDDs and SSDs can be installed via a 2.5\" to 3.5\" drive converter. This chassis does not support hot swap drives which means that drives cannot be added or removed while the server is powered on. The rear of the chassis includes one low-profile PCIe slot, one full-height PCIe slot, a serial port, VGA port, an iDRAC dedicated LAN port, two 1GbE RJ45 Ethernet ports, two type A USB 3.0 ports, CMA port, a system ID button, and one cabled power supply.\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003e4 Bay LFF Hot swap\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003eThe 4 Bay LFF Hot-swap chassis for the R240 server is the exact same as the 4 Bay LFF cabled chassis, except that it accepts hot-swap drives. Hot swap means that you can add or remove drives while the server is powered on. Just like the 4 Bay LFF cabled, the rear of this chassis includes one low-profile PCIe slot, one full-height PCIe slot, a serial port, VGA port, an iDRAC dedicated LAN port, two 1GbE RJ45 Ethernet ports, two type A USB 3.0 ports, CMA port, a system ID button, and one cabled power supply.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c!-- Processing Power Section Order 2 --\u003e\n\u003cdiv class=\"head-content-set\"\u003e\n\u003ch3\u003eProcessing Power\u003c\/h3\u003e\n\u003cdiv class=\"head-content-set-content\"\u003e\n\u003cp\u003eThe Dell PowerEdge R240 server has a single CPU socket that accepts Intel Xeon E-2100, Intel Xeon E-2200, Intel Pentium, Intel Core i3, or Intel Celeron processors. A maximum of 8 CPU cores are supported.\u003c\/p\u003e\n\u003cdiv class=\"outercontainerOfTwoTable\"\u003e\n\u003cdiv class=\"outercontainerOfOneTable\"\u003e\n\u003ch4 class=\"sub-title\"\u003eSupported Intel Xeon E-2100 Processors\u003c\/h4\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eCPU\u003c\/th\u003e\n\u003cth\u003eStep Code\u003c\/th\u003e\n\u003cth\u003eCores\u003c\/th\u003e\n\u003cth\u003eFrequency\u003c\/th\u003e\n\u003cth\u003eCache\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eE-2104G\u003c\/td\u003e\n\u003ctd\u003eSR3WV\u003c\/td\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003ctd\u003e3.2 GHz\u003c\/td\u003e\n\u003ctd\u003e8 MB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eE-2124\u003c\/td\u003e\n\u003ctd\u003eSR3WQ\u003c\/td\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003ctd\u003e3.3 GHz\u003c\/td\u003e\n\u003ctd\u003e8 MB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eE-2124G\u003c\/td\u003e\n\u003ctd\u003eSR3WL\u003c\/td\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003ctd\u003e3.4 GHz\u003c\/td\u003e\n\u003ctd\u003e8 MB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eE-2126G\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e6\u003c\/td\u003e\n\u003ctd\u003e3.3 GHz\u003c\/td\u003e\n\u003ctd\u003e12 MB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eE-2134\u003c\/td\u003e\n\u003ctd\u003eSR3WP\u003c\/td\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003ctd\u003e3.5 GHz\u003c\/td\u003e\n\u003ctd\u003e8 MB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eE-2136\u003c\/td\u003e\n\u003ctd\u003eSR3WW\u003c\/td\u003e\n\u003ctd\u003e6\u003c\/td\u003e\n\u003ctd\u003e3.3 GHz\u003c\/td\u003e\n\u003ctd\u003e12 MB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eE-2144G\u003c\/td\u003e\n\u003ctd\u003eSR3WM\u003c\/td\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003ctd\u003e3.6 GHz\u003c\/td\u003e\n\u003ctd\u003e8 MB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eE-2146G\u003c\/td\u003e\n\u003ctd\u003eSR3WT\u003c\/td\u003e\n\u003ctd\u003e6\u003c\/td\u003e\n\u003ctd\u003e3.5 GHz\u003c\/td\u003e\n\u003ctd\u003e12 MB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eE-2174G\u003c\/td\u003e\n\u003ctd\u003eSR3WN\u003c\/td\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003ctd\u003e3.8 GHz\u003c\/td\u003e\n\u003ctd\u003e8 MB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eE-2176G\u003c\/td\u003e\n\u003ctd\u003eSR3WS\u003c\/td\u003e\n\u003ctd\u003e6\u003c\/td\u003e\n\u003ctd\u003e3.7 GHz\u003c\/td\u003e\n\u003ctd\u003e12 MB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eE-2186G\u003c\/td\u003e\n\u003ctd\u003eSR3WR\u003c\/td\u003e\n\u003ctd\u003e6\u003c\/td\u003e\n\u003ctd\u003e3.8 GHz\u003c\/td\u003e\n\u003ctd\u003e12 MB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"outercontainerOfOneTable\"\u003e\n\u003ch4 class=\"sub-title\"\u003eSupported Intel Xeon E-2200 Processors\u003c\/h4\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eCPU\u003c\/th\u003e\n\u003cth\u003eStep Code\u003c\/th\u003e\n\u003cth\u003eCores\u003c\/th\u003e\n\u003cth\u003eFrequency\u003c\/th\u003e\n\u003cth\u003eCache\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eE-2224\u003c\/td\u003e\n\u003ctd\u003eSRFAV\u003c\/td\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003ctd\u003e3.4 GHz\u003c\/td\u003e\n\u003ctd\u003e8 MB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eE-2224G\u003c\/td\u003e\n\u003ctd\u003eSRFAW\u003c\/td\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003ctd\u003e3.5 GHz\u003c\/td\u003e\n\u003ctd\u003e8 MB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eE-2226G\u003c\/td\u003e\n\u003ctd\u003eSRF7F\u003c\/td\u003e\n\u003ctd\u003e6\u003c\/td\u003e\n\u003ctd\u003e3.4 GHz\u003c\/td\u003e\n\u003ctd\u003e12 MB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eE-2234\u003c\/td\u003e\n\u003ctd\u003eSRFAX\u003c\/td\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003ctd\u003e3.6 GHz\u003c\/td\u003e\n\u003ctd\u003e8 MB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eE-2236\u003c\/td\u003e\n\u003ctd\u003eSRF7G\u003c\/td\u003e\n\u003ctd\u003e6\u003c\/td\u003e\n\u003ctd\u003e3.4 GHz\u003c\/td\u003e\n\u003ctd\u003e12 MB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eE-2244G\u003c\/td\u003e\n\u003ctd\u003eSRFAY\u003c\/td\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003ctd\u003e3.8 GHz\u003c\/td\u003e\n\u003ctd\u003e8 MB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eE-2246G\u003c\/td\u003e\n\u003ctd\u003eSRF7N\u003c\/td\u003e\n\u003ctd\u003e6\u003c\/td\u003e\n\u003ctd\u003e3.6 GHz\u003c\/td\u003e\n\u003ctd\u003e12 MB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eE-2274G\u003c\/td\u003e\n\u003ctd\u003eSRFDE\u003c\/td\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003ctd\u003e4.0 GHz\u003c\/td\u003e\n\u003ctd\u003e8 MB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eE-2276G\u003c\/td\u003e\n\u003ctd\u003eSRF7M\u003c\/td\u003e\n\u003ctd\u003e6\u003c\/td\u003e\n\u003ctd\u003e3.8 GHz\u003c\/td\u003e\n\u003ctd\u003e12 MB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eE-2278G\u003c\/td\u003e\n\u003ctd\u003eSRFB2\u003c\/td\u003e\n\u003ctd\u003e8\u003c\/td\u003e\n\u003ctd\u003e3.4 GHz\u003c\/td\u003e\n\u003ctd\u003e16 MB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eE-2286G\u003c\/td\u003e\n\u003ctd\u003eSRF7C\u003c\/td\u003e\n\u003ctd\u003e6\u003c\/td\u003e\n\u003ctd\u003e4.0 GHz\u003c\/td\u003e\n\u003ctd\u003e12 MB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eE-2288G\u003c\/td\u003e\n\u003ctd\u003eSRFB3\u003c\/td\u003e\n\u003ctd\u003e8\u003c\/td\u003e\n\u003ctd\u003e3.7 GHz\u003c\/td\u003e\n\u003ctd\u003e16 MB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"outercontainerOfTwoTable\"\u003e\n\u003cdiv class=\"outercontainerOfOneTable\"\u003e\n\u003ch4 class=\"sub-title\"\u003eSupported Intel Core i3 Processors\u003c\/h4\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eCPU\u003c\/th\u003e\n\u003cth\u003eStep Code\u003c\/th\u003e\n\u003cth\u003eCores\u003c\/th\u003e\n\u003cth\u003eFrequency\u003c\/th\u003e\n\u003cth\u003eCache\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003ei3-8100\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003ctd\u003e3.6 GHz\u003c\/td\u003e\n\u003ctd\u003e6 MB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ei3-9100\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003ctd\u003e3.60 GHz\u003c\/td\u003e\n\u003ctd\u003e6 MB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"outercontainerOfOneTable\"\u003e\n\u003ch4 class=\"sub-title\"\u003eSupported Intel Celeron\/Pentium Processors\u003c\/h4\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eCPU\u003c\/th\u003e\n\u003cth\u003eStep Code\u003c\/th\u003e\n\u003cth\u003eCores\u003c\/th\u003e\n\u003cth\u003eFrequency\u003c\/th\u003e\n\u003cth\u003eCache\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eCeleron G4900\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003ctd\u003e3.10 GHz\u003c\/td\u003e\n\u003ctd\u003e2 MB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCeleron G4930\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003ctd\u003e3.20 GHz\u003c\/td\u003e\n\u003ctd\u003e2 MB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePentium G5420\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003ctd\u003e3.80 GHz\u003c\/td\u003e\n\u003ctd\u003e4 MB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePentium G5500\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003ctd\u003e3.80 GHz\u003c\/td\u003e\n\u003ctd\u003e4 MB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c!-- Memory Section Order 3 --\u003e\n\u003cdiv class=\"head-content-set\"\u003e\n\u003ch3\u003eMemory\u003c\/h3\u003e\n\u003cp class=\"head-content-set-content\"\u003eThe Dell PowerEdge R240 Server has a total of 4 DIMM slots. There is a total of two memory channels, each consisting of two DIMM slots. This system accepts DDR4 memory. ECC Unbuffered (ECC UDIMM) memory is the only type of memory that can be used with the R240. Capacities of 4GB, 8GB, and 16GB can be used with the PowerEdge R240. The R240 server allows for a maximum memory configuration of 64GB with 4x16GB ECC UDIMMs. The Dell R240 supports memory speeds of 2133MT\/s, 2400MT\/s, 2666MT\/s. The processor you have installed will determine the max memory speed that you can use with your system. For example, if your processor supports a max memory speed off 2400MT\/s and you install a 2666MT\/s module, the module will clock down to 2400MT\/s. 2666MT\/s is the fastest possible speed for this system.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c!-- Storage Section Order 4 --\u003e\n\u003cdiv class=\"head-content-set\"\u003e\n\u003ch3\u003eStorage\u003c\/h3\u003e\n\u003cdiv class=\"head-content-set-content\"\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4 class=\"sub-title\"\u003e\u003cstrong\u003eSupported Drives (2.5\")\u003c\/strong\u003e\u003c\/h4\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eType\u003c\/th\u003e\n\u003cth\u003eSpeeds\u003c\/th\u003e\n\u003cth\u003eMax Capacity (Per Drive)\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSAS\u003c\/td\u003e\n\u003ctd\u003e7.2K, 10K, 15K\u003c\/td\u003e\n\u003ctd\u003e2.4TB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSATA\u003c\/td\u003e\n\u003ctd\u003e7.2K\u003c\/td\u003e\n\u003ctd\u003e2TB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSSD\u003c\/td\u003e\n\u003ctd\u003e6Gb\/s, 12Gb\/s\u003c\/td\u003e\n\u003ctd\u003e7.68TB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"head-content-set-content\"\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4 class=\"sub-title\"\u003e\u003cstrong\u003eSupported Drives (3.5”) \u003c\/strong\u003e\u003c\/h4\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eType\u003c\/th\u003e\n\u003cth\u003eSpeeds\u003c\/th\u003e\n\u003cth\u003eMax Capacity (Per Drive)\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSAS\u003c\/td\u003e\n\u003ctd\u003e7.2K\u003c\/td\u003e\n\u003ctd\u003e18TB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSATA\u003c\/td\u003e\n\u003ctd\u003e7.2K\u003c\/td\u003e\n\u003ctd\u003e16TB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSSD\u003c\/td\u003e\n\u003ctd\u003e6Gb\/s, 12Gb\/s\u003c\/td\u003e\n\u003ctd\u003e7.68TB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c!-- Storage Section Order 4 --\u003e \u003c!--\u003cdiv class=\"head-content-set\"\u003e\n \u003ch3\u003e\u003cspan data-mce-fragment=\"1\"\u003eNVMe Options \u0026amp; Upgrades\u003c\/span\u003e\u003c\/h3\u003e\n \u003cdiv class=\"head-content-set-content\"\u003e\n \u003cp\u003e\n \n \u003c\/p\u003e\n \u003ch4\u003e\u003cstrong\u003eU.2 NVMe\u003c\/strong\u003e\u003c\/h4\u003e\n \u003cp\u003e\n \n \u003c\/p\u003e\n \u003ch4\u003e\u003cstrong\u003ePCIe NVMe\u003c\/strong\u003e\u003c\/h4\u003e\n \u003cp\u003e\n \n \u003c\/p\u003e\n \u003ch4\u003e\u003cstrong\u003eM.2 NVMe\u003c\/strong\u003e\u003c\/h4\u003e\n \u003cp\u003e\n \n \u003c\/p\u003e\n \u003c\/div\u003e\n \u003c\/div\u003e--\u003e \u003c!-- Systems Management Solutions Section Order 7 --\u003e\n\u003cdiv class=\"head-content-set\"\u003e\n\u003ch3\u003ePower Supplies\u003c\/h3\u003e\n\u003cdiv class=\"head-content-set-content\"\u003e\n\u003ch4\u003e\u003cstrong\u003eHow Many Power Supplies does the R240 Support? \u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003eThe Dell PowerEdge R240 server supports up to one cabled power supply. This system does not support hot-swap power supplies meaning that power supply units cannot be removed while the system is powered on.\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003ePower Supply Options\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003eThere are two power supply options for the PowerEdge R240: Bronze 250W and Platinum 450W. For higher-end applications, it is best to go with the 450W option. For lower-end applications, the 250W option is fine.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c!-- Storage Section Order 5 --\u003e\n\u003cdiv class=\"head-content-set\"\u003e\n\u003ch3\u003eRAID Options\u003c\/h3\u003e\n\u003cp class=\"head-content-set-content\"\u003e \u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eRAID Options\u003c\/th\u003e\n\u003cth\u003eRAID Levels\u003c\/th\u003e\n\u003cth\u003eCache\u003c\/th\u003e\n\u003cth\u003eDrive Speeds\u003c\/th\u003e\n\u003cth\u003ePCIe Generation\u003c\/th\u003e\n\u003cth\u003eRAID Hardware\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eS140 onboard software\u003c\/td\u003e\n\u003ctd\u003e0,1,5,10\u003c\/td\u003e\n\u003ctd\u003eNone\u003c\/td\u003e\n\u003ctd\u003e6 Gb\/s SATA\/NVMe\u003c\/td\u003e\n\u003ctd\u003eN\/A\u003c\/td\u003e\n\u003ctd\u003eSoftware\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHBA330\u003c\/td\u003e\n\u003ctd\u003ePassthrough\u003c\/td\u003e\n\u003ctd\u003eNone\u003c\/td\u003e\n\u003ctd\u003e6 Gb\/s SAS\/SATA\u003cbr\u003e12 Gb\/s SAS\u003c\/td\u003e\n\u003ctd\u003ePCIe 3.0\u003c\/td\u003e\n\u003ctd\u003eHardware\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e12Gbps SAS Ext. HBA\u003c\/td\u003e\n\u003ctd\u003ePassthrough\u003c\/td\u003e\n\u003ctd\u003eNone\u003c\/td\u003e\n\u003ctd\u003e12 Gb\/s SAS\u003c\/td\u003e\n\u003ctd\u003ePCIe 3.0\u003c\/td\u003e\n\u003ctd\u003eHardware\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eH330\u003c\/td\u003e\n\u003ctd\u003e0, 1, 5, 10, 50\u003c\/td\u003e\n\u003ctd\u003eNone\u003c\/td\u003e\n\u003ctd\u003e6 Gb\/s SATA\u003cbr\u003e12 Gb\/s SAS\u003c\/td\u003e\n\u003ctd\u003ePCIe 3.0\u003c\/td\u003e\n\u003ctd\u003eHardware\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eH730P\u003c\/td\u003e\n\u003ctd\u003e0, 1, 5, 6, 10, 50, 60\u003c\/td\u003e\n\u003ctd\u003e2 GB NV\u003c\/td\u003e\n\u003ctd\u003e6 Gb\/s SATA\u003cbr\u003e12 Gb\/s SAS\u003c\/td\u003e\n\u003ctd\u003ePCIe 3.0\u003c\/td\u003e\n\u003ctd\u003eHardware\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c!-- Network Interface Card Options Section Order 6 --\u003e \n \u003cdiv class=\"head-content-set\"\u003e\n \u003ch3\u003eNetwork Interface Card Options\u003c\/h3\u003e\n \u003cdiv class=\"head-content-set-content\"\u003e\n \u003cdiv class=\"outercontainerOfTwoTable\"\u003e\n \u003cdiv class=\"outercontainerOfOneTable\"\u003e\n \u003ch4 class=\"sub-title\"\u003eDaughter Cards\u003c\/h4\u003e\n \u003ctable\u003e\n \u003ctbody\u003e\n \u003ctr\u003e\n \u003ctd\u003eBroadcom 5720\/57412 Quad Port 2x1GbE RJ45 + 2x10GbE SFP+\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003ctd\u003eBroadcom 5720 Quad Port 4x1GbE RJ45\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003ctd\u003eBroadcom 57414 Dual Port 2x10\/25GbE SFP28\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003ctd\u003e\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003ctd\u003eIntel i350\/X550 Quad Port 2x1GbE RJ45 + 2x10GbE RJ45\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003ctd\u003eIntel X550 Quad Port 4x10GbE RJ45\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003ctd\u003eIntel X710 Quad Port 4x10GbE SFP+\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003ctd\u003e\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003ctd\u003eMellanox ConnectX-4 Lx Dual Port 10\/25GbE SFP28 V2\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003ctd\u003eMellanox ConnectX-4 Lx Dual Port 10\/25GbE SFP28\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003c\/tbody\u003e\n \u003c\/table\u003e\n \u003c\/div\u003e\n \u003cdiv class=\"outercontainerOfOneTable\"\u003e\n \u003ch4 class=\"sub-title\"\u003ePCIe Cards\u003c\/h4\u003e\n \u003ctable\u003e\n \u003ctbody\u003e\n \u003ctr\u003e\n \u003ctd\u003eBroadcom 5719 Quad Port 4x1GbE RJ45\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003ctd\u003eBroadcom 5720 Dual Port 2x1GbE RJ45\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003ctd\u003eBroadcom 57412 Dual Port 2x10GbE SFP+\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003ctd\u003eBroadcom 57414 Dual Port 2x10\/25GbE SFP28\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003ctd\u003eBroadcom 57416 Dual Port 2x10GbE RJ45\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003ctd\u003eBroadcom 57508 Dual Port 2x100GbE QSFP\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003ctd\u003e\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003ctd\u003eIntel X550 Dual Port 2x10GbE RJ45\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003ctd\u003eIntel X710-T2L Dual Port 2x10GbE RJ45\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003ctd\u003eIntel X710-T4L Quad Port 4x10GbE RJ45\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003ctd\u003eIntel E810-XXV Dual Port 2x10\/25GbE SFP28\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003ctd\u003e\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003ctd\u003eMellanox ConnectX-4 LX Dual Port 2x10\/25GbE SFP28 V2\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003ctd\u003eMellanox ConnectX-4 LX Dual Port 2x10\/25GbE SFP28\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003ctd\u003eMellanox ConnectX-5 Dual Port 2x10\/25GbE SFP28 V2\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003ctd\u003e\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003ctd\u003eEmulex LPE 35002 Dual Port 2x32Gb FC HBA\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003ctd\u003eEmulex LPE 35000 Single Port 1x32Gb FC HBA\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003ctd\u003eEmulex LPe31002 Dual Port 2x16Gb FC HBA V2\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003ctd\u003eEmulex LPe31000 Single Port 1x16Gb FC HBA V2\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003ctd\u003e\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003ctd\u003eQLogic 2690 Single Port 1x16Gb FC HBA V2\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003ctd\u003eQLogic 2772 Dual Port 2x32Gb FC HBA V2\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003c\/tbody\u003e\n \u003c\/table\u003e\n \u003c\/div\u003e\n \u003c\/div\u003e\n \u003c\/div\u003e\n \u003c\/div\u003e\n --\u0026gt; \u003c!-- Systems Management Solutions Section Order 7 --\u003e\n\u003cdiv class=\"head-content-set\"\u003e\n\u003ch3\u003eSystems Management Solutions\u003c\/h3\u003e\n\u003cp class=\"head-content-set-content\"\u003eThe Dell PowerEdge R240 Server utilizes the Integrated Dell Remote Access Controller 9 (iDRAC9), which allows you to easily manage your Dell server. The iDRAC9 web interface provides a variety of useful information and features, that make managing your Dell server an easy task. Features include, but are not limited to hardware monitoring, power control, remote console, control over system settings, firmware update control, storage management, and much more. You can access the iDRAC9 web interface, by setting the iDRAC IP in system setup, and searching the IP in a web browser.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c!-- Systems Management Solutions Section Order 8 --\u003e\n\u003cdiv class=\"head-content-set\"\u003e\n\u003ch3\u003eSupported Operating Systems:\u003c\/h3\u003e\n\u003cp class=\"head-content-set-content\"\u003eThe PowerEdge R240 supports a wide variety of operating systems which ranges from different distributions of Linux, VMware, and Windows Server. These operating systems are:\u003c\/p\u003e\n\u003cul class=\"custom_dots\"\u003e\n\u003cli\u003e⦿ Citrix XenServer 7.1\u003c\/li\u003e\n\u003cli\u003e⦿ Red Hat® Enterprise Linux 7\u003c\/li\u003e\n\u003cli\u003e⦿ Red Hat® Enterprise Linux 8\u003c\/li\u003e\n\u003cli\u003e⦿ Red Hat® Enterprise Linux 9\u003c\/li\u003e\n\u003cli\u003e⦿ SUSE Linux ES 15\u003c\/li\u003e\n\u003cli\u003e⦿ Ubuntu Server 18.04 LTS\u003c\/li\u003e\n\u003cli\u003e⦿ Ubuntu Server 20.04 LTS\u003c\/li\u003e\n\u003cli\u003e⦿ VMware ESXi 6.5\u003c\/li\u003e\n\u003cli\u003e⦿ VMware ESXi 6.7\u003c\/li\u003e\n\u003cli\u003e⦿ VMware ESXi 7.0\u003c\/li\u003e\n\u003cli\u003e⦿ VMware ESXi 8.0\u003c\/li\u003e\n\u003cli\u003e⦿ Window Server 2012 R2\u003c\/li\u003e\n\u003cli\u003e⦿ Window Server 2016\u003c\/li\u003e\n\u003cli\u003e⦿ Window Server 2019\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n \u003cdiv class=\"head-content-set\"\u003e\n\n \u003ch3\u003eDell PowerEdge R240 Video\u003c\/h3\u003e\n \n\u003ciframe srcdoc=\"\n \u0026lt;style\u0026gt;\n body,.full {\n width: 100%;\n height: 100%;\n margin: 0;\n position: absolute;\n display: flex;\n justify-content: center;\n object-fit: cover;\n }\n \u0026lt;\/style\u0026gt;\n \u0026lt;a\n href='https:\/\/www.youtube.com\/embed\/J-gQtz4TgJo?si=q-HuG_i6yk14_ziB'\n class='full'\n rel='follow'\n \u0026gt;\n \u0026lt;img\n src='https:\/\/cdn.shopify.com\/s\/files\/1\/0248\/8539\/5502\/files\/Cloud_Ninjas_N_Logo_White_Background.jpg?v=1661200657'\n class='full'\n \/\u0026gt;\n \u0026lt;svg\n version='1.1'\n viewBox='0 0 68 48'\n width='68px'\n style='position: relative;'\n \u0026gt;\n \u0026lt;path d='M66.52,7.74c-0.78-2.93-2.49-5.41-5.42-6.19C55.79,.13,34,0,34,0S12.21,.13,6.9,1.55 C3.97,2.33,2.27,4.81,1.48,7.74C0.06,13.05,0,24,0,24s0.06,10.95,1.48,16.26c0.78,2.93,2.49,5.41,5.42,6.19 C12.21,47.87,34,48,34,48s21.79-0.13,27.1-1.55c2.93-0.78,4.64-3.26,5.42-6.19C67.94,34.95,68,24,68,24S67.94,13.05,66.52,7.74z' fill='#f00'\u0026gt;\u0026lt;\/path\u0026gt;\n \u0026lt;path d='M 45,24 27,14 27,34' fill='#fff'\u0026gt;\u0026lt;\/path\u0026gt;\n \u0026lt;\/svg\u0026gt;\n \u0026lt;\/a\u0026gt;\n \" style=\" width: 100%; aspect-ratio: 16\/9;\" frameborder=\"0\" title=\"Dell PowerEdge R240 CPU Overview\"\u003e\u003c\/iframe\u003e\n \u003c\/div\u003e\n\u003c\/div\u003e","brand":"Dell","offers":[{"title":"2 Bay LFF Cabled","offer_id":49102946042073,"sku":"Dell-R240-2B-LFF","price":472.49,"currency_code":"USD","in_stock":true},{"title":"4 Bay LFF Hotswap","offer_id":49102946074841,"sku":"Dell-R240-4B-LFF","price":403.65,"currency_code":"USD","in_stock":true}],"url":"https:\/\/www.aloinfousa.com\/pt-latam\/products\/dell-poweredge-r240-server-wy9oy","provider":"aloinfousa.com","version":"1.0","type":"link"}