{"product_id":"endress-hauser-7o2c-proline-prowirl-o200-vortex-flowmeter","title":"Endress+Hauser 7O2C Proline Prowirl O200 Vortex Flowmeter","description":"\u003ch1\u003eOverview\u003c\/h1\u003e\u003cp\u003eEndress+Hauser Proline Prowirl O200 Vortex Flowmeter optimized for requirements of high-pressure mating pipes.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eSpecs at a glance\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e* Max. measurement error\u003cbr\u003eVolume flow (liquid): ±0.75 %\u003cbr\u003eVolume flow (steam, gas): ±1.00 %\u003cbr\u003eMass flow (saturated steam): ±1.7% (temperature compensated); ±1.5% (temperature\/pressure compensated)\u003cbr\u003eMass flow (superheated steam, gas): ±1.5 (temperature\/pressure compensated); ±1.7% (temperature compensated + external pressure\u003cbr\u003ecompensation)\u003cbr\u003eMass flow (liquid): ±0.85%\u003cbr\u003e* Measuring range\u003cbr\u003eLiquid: 0.1 to 1700 m³\/h (0.061 to 1000 ft³\/min)\u003cbr\u003edepending on medium: water with 1 bar a, 20 °C (14.5 psi a, 68° F)\u003cbr\u003eSteam, gas: 0.52 to 22000 m³\/h (0.31 to 13000 ft³\/min)\u003cbr\u003edepending on medium: steam with 180 °C, 10 bar a (356 °F, 145 psi a); air with 25 °C, 4.4 bar a (77 °F, 63.8 psi a)\u003cbr\u003e* Medium temperature range\u003cbr\u003eStandard: –40 to +260 °C (–40 to +500 °F)\u003cbr\u003eHigh\/low temperature (option): –200 to +400 °C (–328 to +752 °F)\u003cbr\u003e* Max. process pressure\u003cbr\u003ePN 250, Class 1500, 40K\u003cbr\u003e* Wetted materials\u003cbr\u003eMeasuring tube: 1.4408 (CF3M)\u003cbr\u003eDSC sensor: UNS N07718 similar to Alloy 718, 2.4668\u003cbr\u003eProcess connection: 1.4404\/F316\/F316L \u003c\/p\u003e\u003ch1\u003eField of application\u003c\/h1\u003e\u003cp\u003eProwirl O is ideally suited for reliable process control in demanding gas and steam applications with high process pressure.Moreover, its design ensures maximum safety in main and ancillary processes. With genuine loop-powered technology, Prowirl O 200 enables cost-effective and seamless integration into existing infrastructures. It offers highest operational safety in hazardous\u003cbr\u003eareas. Heartbeat Technology enables process safety at all times.\u003cbr\u003e* Preferred measuring principle for wet\/saturated\/superheated steam, gases \u0026amp; liquids (also cryogenic)\u003cbr\u003e* The specialist for applications with high process pressure\u003c\/p\u003e\u003cp\u003e\u003cbr\u003eDevice properties\u003cbr\u003e* Saturated steam mass flow up to PN 250 (Class 1500)\u003cbr\u003e* Full compliance with NACE (MR0175\/MR0103)\u003cbr\u003e* Flexible positioning of pressure cell\u003cbr\u003e* Display module with data transfer function\u003cbr\u003e* Robust dual-compartment housing\u003cbr\u003e* Plant safety: worldwide approvals (SIL, Haz. area)\u003c\/p\u003e\u003ch1\u003eBenefits\u003c\/h1\u003e\u003cp\u003e * Better process control – integrated temperature and pressure measurement for steam and gases\u003cbr\u003e* Increased mechanical integrity for flow measurement – special sensor design\u003cbr\u003e* Same accuracy down to Re 10 000 – most linear Vortex meter body\u003cbr\u003e* Long-term stability – robust drift-free capacitive sensor\u003cbr\u003e* Convenient device wiring – separate connection compartment, various Ethernet options\u003cbr\u003e* Safe operation – no need to open the device\u003cbr\u003e* Integrated verification – Heartbeat Technology\u003c\/p\u003e\u003ch1\u003eSpecification\u003c\/h1\u003e\u003cfigure class=\"table\"\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eitem\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003evalue\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eWarranty\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e1 Year\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eCustomized support\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eOEM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003ePlace of Origin\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eGermany\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eBrand Name\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eEndress+Hauser\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eModel Number\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eProwirl O200\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eType\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eVortex Flowmeter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eProduct Headline\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eFlowmeter optimized for requirements of high-pressure mating pipes. \u003cbr\u003eBetter process control – integrated temperature and pressure measurement for steam and gases. \u003cbr\u003eThe specialist for applications with high process pressure.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eSensor Features\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eIncreased mechanical integrity for flow measurement – special sensor design. Same accuracy down to Re 10 000 – most linear Vortex \u003cbr\u003emeter body. Long-term stability – robust drift-free capacitive sensor. \u003cbr\u003eSaturated steam mass flow up to PN 250 (Class 1500). Full compliance with NACE (MR0175\/MR0103). Flexible positioning of pressure \u003cbr\u003ecell.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eTransmitter Features\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eConvenient device wiring – separate connection compartment. Safe operation – no need to open the device due to display with touch \u003cbr\u003econtrol, background lighting. Integrated verification – Heartbeat Technology. \u003cbr\u003eDisplay module with data transfer function. Robust dual-compartment housing. Plant safety: worldwide approvals (SIL, Haz. area).\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eNominal Diameter Range\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eDN 15 to 300 (½ to 12\")\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eWetted Materials\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eMeasuring tube: 1.4408 (CF3M) \u003cbr\u003eDSC sensor: UNS N07718 similar to Alloy 718, 2.4668 \u003cbr\u003eProcess connection: 1.4404\/F316\/F316L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eMeasured Variables\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eVolume flow, mass flow, corrected volume flow, energy flow, heat flow difference, temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eMax. Measurement Error\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eVolume flow (liquid): ±0.75 % \u003cbr\u003eVolume flow (steam, gas): ±1.00 % \u003cbr\u003eMass flow (saturated steam): ±1.7% (temperature compensated); ±1.5% (temperature\/pressure compensated) \u003cbr\u003eMass flow (superheated steam, gas): ±1.5 (temperature\/pressure compensated); ±1.7% (temperature compensated + external pressure \u003cbr\u003ecompensation) \u003cbr\u003eMass flow (liquid): ±0.85%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eMeasuring Range\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eLiquid: 0.1 to 1700 m³\/h (0.061 to 1000 ft³\/min) \u003cbr\u003edepending on medium: water with 1 bar a, 20 °C (14.5 psi a, 68° F) \u003cbr\u003eSteam, gas: 0.52 to 22000 m³\/h (0.31 to 13000 ft³\/min) \u003cbr\u003edepending on medium: steam with 180 °C, 10 bar a (356 °F, 145 psi a); air with 25 °C, 4.4 bar a (77 °F, 63.8 psi a)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eMax. Process Ppressure\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003ePN 250, Class 1500, 40K\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eMedium Temperature Range\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eStandard: –40 to +260 °C (–40 to +500 °F) \u003cbr\u003eHigh\/low temperature (option): –200 to +400 °C (–328 to +752 °F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eAmbient Temperature Range\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eCompact version (standard): –40 to +80 °C (–40 to +176 °F) \u003cbr\u003eCompact version (option): –50 to +80 °C (–58 to +176 °F) \u003cbr\u003eRemote version (standard): –40 to +85 °C (–40 to +185 °F) \u003cbr\u003eRemote version (option): –50 to +85 °C (–58 to +185 °F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eSensor Housing Material\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eSensor connection housing: AlSi10Mg, coated; 1.4408 (CF3M)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eTransmitter Housing Material\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eAlSi10Mg, coated; 1.4404 (316L)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eDegree Of Protection\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eCompact version: IP66\/67, type 4X enclosure \u003cbr\u003eSensor remote version: IP66\/67, type 4X enclosure \u003cbr\u003eTransmitter remote version: IP66\/67, type 4X enclosure\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eDisplay\/Operation\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e4‐line backlit display with touch control (operation from outside) \u003cbr\u003eConfiguration via local display and operating tools possible \u003cbr\u003eRemote display available\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eOutputs\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e4‐20 mA HART (passive) \u003cbr\u003e4‐20 mA (passive) \u003cbr\u003ePulse\/frequency\/switch output (passive)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eInputs\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e4‐20 mA (passive)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eDigital Communication\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eHART, PROFIBUS PA, FOUNDATION Fieldbus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003ePower Supply\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eDC 12 to 35 V (4‐20 mA HART with\/without pulse\/frequency\/switch output) \u003cbr\u003eDC 12 to 30 V (4‐20 mA HART, 4‐20 mA) \u003cbr\u003eDC 12 to 35 V (4‐20 mA HART, pulse\/frequency\/switch output, 4‐20 mA input) \u003cbr\u003eDC 9 to 32 V (PROFIBUS PA, pulse\/frequency\/switch output)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eHazardous Area Approvals\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eATEX, IECEx, cCSAus, JPN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eProduct Safety\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eCE, C-TICK, EAC, UK Ex\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eFunctional Safety\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eFunctional safety according to IEC 61508, applicable in safety-relevant applications in accordance with IEC 61511\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eMetrological Approvals And Certificates\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eCalibration performed on accredited calibration facilities (acc. to ISO\/IEC 17025) \u003cbr\u003eHeartbeat Technology complies with the requirements for measurement traceability according to ISO 9001:2015 – Section 7.1.5.2 a \u003cbr\u003e(TÜV SÜD attestation)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eMarine aApprovals And Certificates\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eABS, LR, BV, DNV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003ePressure Approvals And Certificates\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003ePED, CRN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eMaterial Certificates\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e3.1 material \u003cbr\u003eNACE MR0175\/MR0103, PMI (on request); only Class 900\/1500: welding test acc. to ISO 15614‐1, similar to ASME IX (on request)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/figure\u003e\u003cp\u003e \u003c\/p\u003e","brand":"Endress+Hauser","offers":[{"title":"Default Title","offer_id":48020369047769,"sku":null,"price":3062.5,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0016\/5327\/6707\/files\/Endress_Hauser_7O2C_Proline_Prowirl_O_200_Vortex_Flowmeter.png?v=1771970621","url":"https:\/\/www.aloinfousa.com\/pt\/products\/endress-hauser-7o2c-proline-prowirl-o200-vortex-flowmeter","provider":"aloinfousa.com","version":"1.0","type":"link"}