{"product_id":"endress-hauser-7r2c-proline-prowirl-r200-vortex-flowmeter","title":"Endress+Hauser 7R2C Proline Prowirl R200 Vortex Flowmeter","description":"\u003ch1\u003eoverview\u003c\/h1\u003e\u003cp\u003eEndress+Hauser 7R2C Proline Prowirl R200 Vortex Flowmeter with best-in-class accuracy despite pipe reduction.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eSpecs at a glance\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e* Max. measurement error \u003cbr\u003eVolume flow (liquid): ±0.75 % \u003cbr\u003eVolume flow (steam, gas): ±1.00 % \u003cbr\u003eMass flow (saturated steam): ±1.7% (temperature compensated); ±1.5% (temperature\/pressure compensated) \u003cbr\u003eMass flow (superheated steam, gas): ±1.5 (temperature\/pressure compensated); ±1.7% (temperature compensated + external pressure \u003cbr\u003ecompensation) \u003cbr\u003eMass flow (liquid): ±0.85% \u003cbr\u003e* Measuring range \u003cbr\u003eLiquid: 0.1 to 540 m³\/h (0.061 to 320 ft³\/min) \u003cbr\u003edepending on medium: water with 1 bar a, 20 °C (14.5 psi a, 68° F) \u003cbr\u003eSteam, gas: 0.52 to 7300 m³\/h (0.31 to 4300 ft³\/min) \u003cbr\u003edepending on medium: steam with 180 °C, 10 bar a (356 °F, 145 psi a); air with 25 °C, 4.4 bar a (77 °F, 63.8 psi a) \u003cbr\u003e* Medium temperature range \u003cbr\u003eStandard: –40 to +260 °C (–40 to +500 °F) \u003cbr\u003eHigh\/low temperature (option): –200 to +400 °C (–328 to +752 °F) \u003cbr\u003eHigh\/low temperature (on request): –200 to +450 °C (–328 to +842 °F) \u003cbr\u003e* Max. process pressure \u003cbr\u003ePN 40, Class 300, 20K \u003cbr\u003e* Wetted materials \u003cbr\u003eMeasuring tube: 1.4408 (CF3M) \u003cbr\u003eDSC sensor: 1.4404\/F316\/F316L \u003cbr\u003eProcess connection: 1.4404\/F316\/F316L\u003c\/p\u003e\u003ch1\u003eField of application\u003c\/h1\u003e\u003cp\u003eProwirl R was designed for low flows and is thus the particularly dependable solution for energy management. Additionally its calibration option PremiumCal guarantees excellent measuring accuracy for maximum plant availability. With genuine loop-powered technology, Prowirl R 200 enables cost-effective and seamless integration into existing infrastructures. It offers highest operational safety in hazardous areas. Heartbeat Technology enables process safety at all times.\u003cbr\u003e* Preferred measuring principle for wet\/saturated\/superheated steam, gases \u0026amp; liquids (also cryogenic)\u003cbr\u003e* Dedicated to applications with very low or reduced flow Device properties\u003cbr\u003e* Integrated diameter reduction by 1 or 2 line sizes\u003cbr\u003e* Nominal diameter (mating pipe) up to DN 250 (10\")\u003cbr\u003e* Flexible positioning of pressure cell\u003cbr\u003e* Display module with data transfer function\u003cbr\u003e* Robust dual-compartment housing\u003cbr\u003e* Plant safety: worldwide approvals (SIL, Haz. area)\u003c\/p\u003e\u003ch1\u003eBenefits\u003c\/h1\u003e\u003cp\u003e * Easy energy management – integrated temperature and pressure measurement for steam and gases\u003cbr\u003e* Cost and time savings – no pipework modifications needed for line size reduction\u003cbr\u003e* Same accuracy down to Re 10 000 – most linear Vortex meter body\u003cbr\u003e* Long-term stability – robust drift-free capacitive sensor\u003cbr\u003e* Convenient device wiring – separate connection compartment, various Ethernet options\u003cbr\u003e* Safe operation – no need to open the device\u003cbr\u003e* Integrated verification – Heartbeat Technology\u003c\/p\u003e\u003ch1\u003eSpecification\u003c\/h1\u003e\u003cfigure class=\"table\"\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eitem\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003evalue\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eWarranty\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e1 Year\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eCustomized support\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eOEM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003ePlace of Origin\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eGermany\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eBrand Name\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eEndress+Hauser\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eModel Number\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eProwirl R200\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eType\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eVortex Flowmeter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eProduct Headline\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eFlowmeter with best-in-class accuracy despite pipe reduction. \u003cbr\u003eEasy energy management – integrated temperature and pressure measurement for steam and gases. \u003cbr\u003eDedicated to applications with very low flow or reduced flow.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eSensor Features\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eCost and time savings – no pipework modifications needed for line size reduction. Same accuracy down to Re 10 000 – most linear \u003cbr\u003eVortex meter body. Long-term stability – robust drift-free capacitive sensor. Integrated diameter reduction by 1 or 2 line sizes. \u003cbr\u003eNominal diameter (mating pipe) up to DN 250 (10\").\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eTransmitter Features\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eCost and time savings – no pipework modifications needed for line size reduction. Same accuracy down to Re 10 000 – most linear \u003cbr\u003eVortex meter body. Long-term stability – robust drift-free capacitive sensor. \u003cbr\u003eIntegrated diameter reduction by 1 or 2 line sizes. Nominal diameter (mating pipe) up to DN 250 (10\"). Flexible positioning of \u003cbr\u003epressure cell.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eNominal Diameter Range\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eDN 25 to 250 (1 to 10\")\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eWetted Materials\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eMeasuring tube: 1.4408 (CF3M) \u003cbr\u003eDSC sensor: 1.4404\/F316\/F316L \u003cbr\u003eProcess connection: 1.4404\/F316\/F316L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eMeasured Variables\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eVolume flow, mass flow, corrected volume flow, energy flow, heat flow difference, temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eMax. Measurement Error\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eVolume flow (liquid): ±0.75 % \u003cbr\u003eVolume flow (steam, gas): ±1.00 % \u003cbr\u003eMass flow (saturated steam): ±1.7% (temperature compensated); ±1.5% (temperature\/pressure compensated) \u003cbr\u003eMass flow (superheated steam, gas): ±1.5 (temperature\/pressure compensated); ±1.7% (temperature compensated + external pressure \u003cbr\u003ecompensation) \u003cbr\u003eMass flow (liquid): ±0.85%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eMeasuring Range\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eLiquid: 0.1 to 540 m³\/h (0.061 to 320 ft³\/min) \u003cbr\u003edepending on medium: water with 1 bar a, 20 °C (14.5 psi a, 68° F) \u003cbr\u003eSteam, gas: 0.52 to 7300 m³\/h (0.31 to 4300 ft³\/min) \u003cbr\u003edepending on medium: steam with 180 °C, 10 bar a (356 °F, 145 psi a); air with 25 °C, 4.4 bar a (77 °F, 63.8 psi a)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eMax. Process Ppressure\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003ePN 40, Class 300, 20K\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eMedium Temperature Range\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eStandard: –40 to +260 °C (–40 to +500 °F) \u003cbr\u003eHigh\/low temperature (option): –200 to +400 °C (–328 to +752 °F) \u003cbr\u003eHigh\/low temperature (on request): –200 to +450 °C (–328 to +842 °F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eAmbient Temperature Range\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eCompact version (standard): –40 to +80 °C (–40 to +176 °F) \u003cbr\u003eCompact version (option): –50 to +80 °C (–58 to +176 °F) \u003cbr\u003eRemote version (standard): –40 to +85 °C (–40 to +185 °F) \u003cbr\u003eRemote version (option): –50 to +85 °C (–58 to +185 °F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eSensor Housing Material\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eSensor connection housing: AlSi10Mg, coated; 1.4408 (CF3M)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eTransmitter Housing Material\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eAlSi10Mg, coated; 1.4404 (316L)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eDegree Of Protection\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eCompact version: IP66\/67, type 4X enclosure \u003cbr\u003eSensor remote version: IP66\/67, type 4X enclosure \u003cbr\u003eTransmitter remote version: IP66\/67, type 4X enclosure\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eDisplay\/Operation\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e4‐line backlit display with touch control (operation from outside) \u003cbr\u003eConfiguration via local display and operating tools possible \u003cbr\u003eRemote display available\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eOutputs\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e4‐20 mA HART (passive) \u003cbr\u003e4‐20 mA (passive) \u003cbr\u003ePulse\/frequency\/switch output (passive)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eInputs\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e4‐20 mA (passive)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eDigital Communication\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eHART, PROFIBUS PA, FOUNDATION Fieldbus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003ePower Supply\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eDC 12 to 35 V (4‐20 mA HART with\/without pulse\/frequency\/switch output) \u003cbr\u003eDC 12 to 30 V (4‐20 mA HART, 4‐20 mA) \u003cbr\u003eDC 12 to 35 V (4‐20 mA HART, pulse\/frequency\/switch output, 4‐20 mA input) \u003cbr\u003eDC 9 to 32 V (PROFIBUS PA, pulse\/frequency\/switch output)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eHazardous Area Approvals\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eATEX, IECEx, cCSAus, JPN, EAC, UK Ex\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eProduct Safety\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eCE, C-tick, EAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eFunctional Safety\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eFunctional safety according to IEC 61508, applicable in safety-relevant applications in accordance with IEC 61511\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eMetrological Approvals And Certificates\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eCalibration performed on accredited calibration facilities (acc. to ISO\/IEC 17025) \u003cbr\u003eHeartbeat Technology complies with the requirements for measurement traceability according to ISO 9001:2015 – Section 7.1.5.2 a \u003cbr\u003e(TÜV SÜD attestation)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eMarine aApprovals And Certificates\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eABS, LR, BV, DNV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003ePressure Approvals And Certificates\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003ePED, CRN, AD 2000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eMaterial Certificates\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e3.1 material \u003cbr\u003eNACE MR0175\/MR0103, PMI (on request); welding test acc. to ISO 15614‐1, similar to ASME IX (on request)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/figure\u003e\u003cp\u003e \u003c\/p\u003e","brand":"Endress+Hauser","offers":[{"title":"Default Title","offer_id":48020369178841,"sku":null,"price":3375.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0016\/5327\/6707\/files\/Endress_Hauser_7R2C_Proline_Prowirl_R_200_Vortex_Flowmeter.png?v=1771970623","url":"https:\/\/www.aloinfousa.com\/pt\/products\/endress-hauser-7r2c-proline-prowirl-r200-vortex-flowmeter","provider":"aloinfousa.com","version":"1.0","type":"link"}