{"product_id":"siemens-sitrans-fus380-fue380-7me340-transmitter","title":"SIEMENS SITRANS FUS380\/FUE380 7ME340 Transmitter","description":"\u003cstyle type=\"text\/css\"\u003e#detail_decorate_root .magic-0{width:750px}#detail_decorate_root .magic-1{overflow:hidden;width:750px;height:587px;margin-top:0;margin-bottom:0;margin-left:0;margin-right:0}#detail_decorate_root .magic-2{margin-top:0;margin-left:0;width:750px;height:587px}#detail_decorate_root .magic-3{overflow:hidden;width:750px;height:73px;margin-top:0;margin-bottom:0;margin-left:0;margin-right:0}#detail_decorate_root .magic-4{margin-top:0;margin-left:0;width:750px;height:73px}#detail_decorate_root .magic-5{width:446px}#detail_decorate_root .magic-6{overflow:hidden;width:446px;height:446px;margin-top:0;margin-bottom:0;margin-left:0;margin-right:0}#detail_decorate_root .magic-7{margin-top:0;margin-left:0;width:446px;height:446px}#detail_decorate_root .magic-8{width:300px;display:flex;flex-direction:column;margin-right:0;margin-left:4px}#detail_decorate_root .magic-9{font-size:20px}#detail_decorate_root .magic-10{vertical-align:top}#detail_decorate_root .magic-11{padding:0;margin:0;color:#333;font-size:14px;padding-left:4px;font-weight:bold;white-space:pre-wrap}#detail_decorate_root .magic-12{vertical-align:top;display:block;padding-right:4px;box-sizing:border-box;padding-left:4px}#detail_decorate_root .magic-13{vertical-align:top;padding-bottom:4px;box-sizing:border-box;padding-top:4px}#detail_decorate_root .magic-14{padding:0;margin:0;white-space:pre-wrap;font-size:14px}#detail_decorate_root .magic-15{overflow:hidden;width:750px;height:75px;margin-top:0;margin-bottom:0;margin-left:0;margin-right:0}#detail_decorate_root .magic-16{margin-top:0;margin-left:0;width:750px;height:75px}#detail_decorate_root .magic-17{width:750px;border-collapse:collapse}#detail_decorate_root .magic-18{min-height:28px;padding:5px 10px;width:259px;min-height:28px;box-sizing:content-box}#detail_decorate_root .magic-19{min-height:28px;padding:5px 10px;width:442px;min-height:28px;box-sizing:content-box}#detail_decorate_root .magic-20{overflow:hidden;width:750px;height:356.80242634315425px;margin-top:0;margin-bottom:0;margin-left:0;margin-right:0}#detail_decorate_root .magic-21{margin-top:0;margin-left:0;width:750px;height:356.80242634315425px}#detail_decorate_root .magic-22{overflow:hidden;width:750px;height:519.7311361665221px;margin-top:0;margin-bottom:0;margin-left:0;margin-right:0}#detail_decorate_root .magic-23{margin-top:0;margin-left:0;width:750px;height:519.7311361665221px}#detail_decorate_root .magic-24{margin-bottom:10px;overflow:hidden}#detail_decorate_root .magic-25{overflow:hidden;width:750px;height:1078px;margin-top:0;margin-bottom:0;margin-left:0;margin-right:0}#detail_decorate_root .magic-26{margin-top:0;margin-left:0;width:750px;height:1078px}#detail_decorate_root .magic-27{overflow:hidden;width:750px;height:814px;margin-top:0;margin-bottom:0;margin-left:0;margin-right:0}#detail_decorate_root .magic-28{margin-top:0;margin-left:0;width:750px;height:814px}#detail_decorate_root .magic-29{overflow:hidden;width:750px;height:758px;margin-top:0;margin-bottom:0;margin-left:0;margin-right:0}#detail_decorate_root .magic-30{margin-top:0;margin-left:0;width:750px;height:758px}#detail_decorate_root .magic-31{overflow:hidden;width:750px;height:583px;margin-top:0;margin-bottom:0;margin-left:0;margin-right:0}#detail_decorate_root .magic-32{margin-top:0;margin-left:0;width:750px;height:583px}#detail_decorate_root .magic-33{overflow:hidden;width:750px;height:893px;margin-top:0;margin-bottom:0;margin-left:0;margin-right:0}#detail_decorate_root .magic-34{margin-top:0;margin-left:0;width:750px;height:893px}#detail_decorate_root .magic-35{overflow:hidden;width:750px;height:675px;margin-top:0;margin-bottom:0;margin-left:0;margin-right:0}#detail_decorate_root .magic-36{margin-top:0;margin-left:0;width:750px;height:675px}#detail_decorate_root .magic-37{overflow:hidden;width:750px;height:76px;margin-top:0;margin-bottom:0;margin-left:0;margin-right:0}#detail_decorate_root .magic-38{margin-top:0;margin-left:0;width:750px;height:76px}\n\u003c\/style\u003e\n\u003cdiv id=\"detail_decorate_root\" data-magic-global=\"%7B%22bizId%22%3A2217607044645%2C%22pageId%22%3A200111355463%2C%22siteId%22%3A10100897032%7D\"\u003e\n\u003cdiv class=\"J_module\" render=\"true\" module-title=\"detailSingleImage\" module-id=\"201243190078\"\u003e\n\u003cdiv class=\"icbu-pc-images magic-0\"\u003e\n\u003cdiv class=\"flex-layout-v\"\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"J_module\" render=\"true\" module-title=\"detailHorizontalImageText\" module-id=\"201243190080\"\u003e\n\u003cdiv class=\"icbu-pc-images magic-0\"\u003e\n\u003cdiv\u003e\n\u003cdiv class=\"flex-layout-h\"\u003e\n\u003cdiv class=\"text-wrapper magic-8\"\u003e\n\u003cdiv class=\"text-wrapper-right text-theme-light text-align-left\"\u003e\n\u003ch1 class=\"text-title\"\u003e\u003cspan style=\"color: rgb(13, 67, 146);\"\u003eOverview\u003c\/span\u003e\u003c\/h1\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv render=\"true\" module-title=\"detailTextWithTitle\" module-id=\"201243190081\"\u003e\n\u003cdiv class=\"text-title\"\u003e\n\u003cdiv\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv\u003eThe 2-path flowmeter SITRANS FUS380 comes as battery or mains powered and is designed to measure water flow in district heating plants, local networks, boiler stations, substations, chiller plants (including glycol mixes) and other general water applications.\u003cbr\u003eThe type-approved flowmeter version is named SITRANS FUE380.\u003cbr\u003eTechnically, the meter types SITRANS FUS380 and SITRANS FUE380 are completely identical, only difference is the calibration limit and\u003cbr\u003ethe type approval for custody transfer.\u003c\/div\u003e\n\u003cdiv\u003e\u003c\/div\u003e\n\u003cdiv\u003e\n\u003ch1\u003e\u003cspan style=\"color: rgb(13, 67, 146);\"\u003eBenefits\u003c\/span\u003e\u003c\/h1\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e* Battery-powered up to 6 years\u003cbr\u003e* 115\/230 V mains-powered with back-up battery option in case of mains power failure\u003cbr\u003e* Fast measuring frequency 15 Hz\/0.5 Hz (230 V AC\/Battery)\u003cbr\u003e* Easy one-button straight forward display\u003cbr\u003e* 2-path measuring principle for optimum accuracy\u003cbr\u003e* Compact or remote mounting\u003cbr\u003e* Measures on most district water qualities and water conductivities\u003cbr\u003e* No pressure drop\u003cbr\u003e* Long-term stability\u003cbr\u003e* 2 galvanically isolated digital outputs for easy connection to a calculator (potential-free)\u003cbr\u003e* Analog output 4 to 20 mA\u003cbr\u003e* Bidirectional measurement, with 2 totalizers and outputs\u003cbr\u003e* Dynamic range qi (min) : qs (max) up to 1:400\u003c\/div\u003e\n\u003cdiv\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv render=\"true\" module-title=\"detailTextWithTitle\" module-id=\"201243190082\"\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cdiv\u003eThe main application for SITRANS FUS380 is measurement of water flow or water flow in energy meter systems in district heating networks or chilled water (including glycol mixes).\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv render=\"true\" module-title=\"detailTextWithTitle\" module-id=\"201243190083\"\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\u003c\/div\u003e\n\u003cdiv\u003eThe 2-path design of SITRANS FUS380 ensures maximum accuracy under short inlet conditions. The flowmeter consists of a flow sensor pipe, 4 transducers\/transducer cables and a transmitter SITRANS FUE080.\u003cbr\u003eThe unit is available in a compact or a remote version. Both versions are pre-mounted with short coax-cables. Remote transmitter up to a distance of 30 m by one Sensor link cable (SSL). Compact mounting is only possible up to 120 °C (248 °F). The sensor must be isolated to protect transmitter from heat. The transmitter is available in an IP67\/NEMA 4X\/6 enclosure.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv render=\"true\" module-title=\"detailTextWithTitle\" module-id=\"201243190084\"\u003e\n\u003ch3\u003e\u003cbr\u003e\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cdiv\u003eThe flowmeter digital output is often used as input for an energy meter or as input for digital systems for remote reading. SITRANS FUS380 has two digital output functions that can be individually selected. Pulse output rate is defined when ordering. To get optimal benefit the pulse value must be selected as low as possible. If the flowmeter forms part of an energy meter system for custody transfer, no further approvals are needed, except possible local approvals on the flowmeter.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv render=\"true\" module-title=\"detailTextWithTitle\" module-id=\"201242152954\"\u003e\n\u003ch3\u003e\u003cbr\u003e\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cdiv\u003eTogether with the SIMATIC PDM tool the FUS380 offers the possibility of testing and verifying the flowmeter on site and creating a printed ”Qualification Certificate” with specific data that defines the quality status of the measurement.\u003cbr\u003eThe Qualification Certificate shows information about the actual status of the flowmeter:\u003cbr\u003e* General settings, flowmeter and battery information, totalizer values, and pulse output settings\u003cbr\u003e* Detailed information about the transmitter and the sensor functionality, and a main parameter list for evaluating the functionality of the flowmeter.\u003c\/div\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003ch1\u003e\u003cspan style=\"color: rgb(13, 67, 146);\"\u003eSpecification\u003c\/span\u003e\u003c\/h1\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv render=\"true\" module-title=\"detailTableHorizontal\" module-id=\"201243190086\"\u003e\n\u003cdiv\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"1\" colspan=\"1\"\u003e\n\u003cdiv\u003eitem\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd rowspan=\"1\" colspan=\"1\"\u003e\n\u003cdiv\u003evalue\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"1\" colspan=\"1\"\u003e\n\u003cdiv\u003eMeasuring Range\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd rowspan=\"1\" colspan=\"1\"\u003e\n\u003cdiv\u003eQp 15 to 36000 m³\/h (depends on size)\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"1\" colspan=\"1\"\u003e\n\u003cdiv\u003eNominal Size\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd rowspan=\"1\" colspan=\"1\"\u003e\n\u003cdiv\u003eDN 50 to DN 1200 (2\" to 48\")\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"1\" colspan=\"1\"\u003e\n\u003cdiv\u003eAccuracy\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd rowspan=\"1\" colspan=\"1\"\u003e\n\u003cdiv\u003e±0.5% of flow rate\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"1\" colspan=\"1\"\u003e\n\u003cdiv\u003eOperational Pressure\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd rowspan=\"1\" colspan=\"1\"\u003e\n\u003cdiv\u003ePressure rate max. PN 40\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"1\" colspan=\"1\"\u003e\n\u003cdiv\u003eOperation Temperature\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd rowspan=\"1\" colspan=\"1\"\u003e\n\u003cdiv\u003e0 … 60 °C (32 … 140 °F)\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"1\" colspan=\"1\"\u003e\n\u003cdiv\u003eMedium Temperature\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd rowspan=\"1\" colspan=\"1\"\u003e\n\u003cdiv\u003e2 … 200 °C (35.6 … 392 °F)\u003cbr\u003eBronze: Up to 150 °C (302 °F)\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"1\" colspan=\"1\"\u003e\n\u003cdiv\u003eDesign\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd rowspan=\"1\" colspan=\"1\"\u003e\n\u003cdiv\u003e2-path sensor with flanges and integrated transducers\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"1\" colspan=\"1\"\u003e\n\u003cdiv\u003eMaterial\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd rowspan=\"1\" colspan=\"1\"\u003e\n\u003cdiv\u003eCarbon steel Bronze (only DN 50 to 80)\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"1\" colspan=\"1\"\u003e\n\u003cdiv\u003eNominal Size \u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd rowspan=\"1\" colspan=\"1\"\u003e\n\u003cdiv\u003eDN 50 … 80 in bronze\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"1\" colspan=\"1\"\u003e\n\u003cdiv\u003ePipe Material\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd rowspan=\"1\" colspan=\"1\"\u003e\n\u003cdiv\u003eDN 100 … 1200: Carbon Steel\u003cbr\u003eEN 1.0345\/P235 GH, painted in light-gray\u003cbr\u003e• DN 50 … 80: Die-cast bronze G\u003cbr\u003eCuSn10\/W2.1050.01 (EN 1982\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"1\" colspan=\"1\"\u003e\n\u003cdiv\u003eTransducer Material\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd rowspan=\"1\" colspan=\"1\"\u003e\n\u003cdiv\u003eStainless steel (AISI 316\/1.4404)\/brass (CuZn\u003cbr\u003e36Pb2As)\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"1\" colspan=\"1\"\u003e\n\u003cdiv\u003eDegree Of Protection\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd rowspan=\"1\" colspan=\"1\"\u003e\n\u003cdiv\u003eSensor connection IP67\/NEMA 4X\/6\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"1\" colspan=\"1\"\u003e\n\u003cdiv\u003eMax. Flow Velocity\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd rowspan=\"1\" colspan=\"1\"\u003e\n\u003cdiv\u003eDN 50 … 1200: 9 m\/s (29.5 ft\/s)\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"1\" colspan=\"1\"\u003e\n\u003cdiv\u003eSensor Cable\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd rowspan=\"1\" colspan=\"1\"\u003e\n\u003cdiv\u003ePre-mounted with short coax-cables\u003cbr\u003e5, 10, 20, 30 m (16.4, 32.8, 65.6, 98.4 ft)\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"J_module\" render=\"true\" module-title=\"detailSingleImage\" module-id=\"201243190087\"\u003e\n\u003cdiv class=\"icbu-pc-images magic-0\"\u003e\n\u003cdiv class=\"flex-layout-v\"\u003e\n\u003cdiv class=\"flex-layout-h magic-0\"\u003e\n\u003cdiv class=\"magic-20\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"J_module\" render=\"true\" module-title=\"detailSingleImage\" module-id=\"201242152955\"\u003e\n\u003cdiv class=\"icbu-pc-images magic-0\"\u003e\n\u003cdiv class=\"flex-layout-v\"\u003e\n\u003cdiv class=\"flex-layout-h magic-0\"\u003e\n\u003cdiv class=\"magic-22\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"SIEMENS","offers":[{"title":"Default Title","offer_id":48020392411353,"sku":null,"price":1375.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0016\/5327\/6707\/files\/SIEMENS_SITRANS_FUS380_FUE380_7ME340_Transmitter.jpg?v=1771971012","url":"https:\/\/www.aloinfousa.com\/pt\/products\/siemens-sitrans-fus380-fue380-7me340-transmitter","provider":"aloinfousa.com","version":"1.0","type":"link"}