{"product_id":"siemens-ultrasonic-clamp-on-flow-measurement-sitrans-fst070-7me372-7me3448-6es7193","title":"SIEMENS Ultrasonic Clamp-on Flow Measurement SITRANS FST070 7ME372 7ME3448 6ES7193","description":"\u003cstyle type=\"text\/css\"\u003e#detail_decorate_root .magic-0{width:750px}#detail_decorate_root .magic-1{overflow:hidden;width:750px;height:587px;margin-top:0;margin-bottom:0;margin-left:0;margin-right:0}#detail_decorate_root .magic-2{margin-top:0;margin-left:0;width:750px;height:587px}#detail_decorate_root .magic-3{overflow:hidden;width:750px;height:73px;margin-top:0;margin-bottom:0;margin-left:0;margin-right:0}#detail_decorate_root .magic-4{margin-top:0;margin-left:0;width:750px;height:73px}#detail_decorate_root .magic-5{width:446px}#detail_decorate_root .magic-6{overflow:hidden;width:446px;height:446px;margin-top:0;margin-bottom:0;margin-left:0;margin-right:0}#detail_decorate_root .magic-7{margin-top:0;margin-left:0;width:446px;height:446px}#detail_decorate_root .magic-8{width:300px;display:flex;flex-direction:column;margin-right:0;margin-left:4px}#detail_decorate_root .magic-9{font-size:20px}#detail_decorate_root .magic-10{vertical-align:top}#detail_decorate_root .magic-11{padding:0;margin:0;color:#333;font-size:14px;padding-left:4px;font-weight:bold;white-space:pre-wrap}#detail_decorate_root .magic-12{vertical-align:top;display:block;padding-right:4px;box-sizing:border-box;padding-left:4px}#detail_decorate_root .magic-13{vertical-align:top;padding-bottom:4px;box-sizing:border-box;padding-top:4px}#detail_decorate_root .magic-14{padding:0;margin:0;white-space:pre-wrap;font-size:14px}#detail_decorate_root .magic-15{border-bottom-style:solid;border-bottom-color:#53647a;font-family:Roboto;font-size:24px;color:#53647a;font-style:normal;border-bottom-width:2px;padding-top:8px;padding-bottom:4px}#detail_decorate_root .magic-16{overflow:hidden;width:750px;height:75px;margin-top:0;margin-bottom:0;margin-left:0;margin-right:0}#detail_decorate_root .magic-17{margin-top:0;margin-left:0;width:750px;height:75px}#detail_decorate_root .magic-18{width:750px;border-collapse:collapse}#detail_decorate_root .magic-19{min-height:28px;padding:5px 10px;width:259px;min-height:28px;box-sizing:content-box}#detail_decorate_root .magic-20{min-height:28px;padding:5px 10px;width:442px;min-height:28px;box-sizing:content-box}#detail_decorate_root .magic-21{margin-bottom:10px;line-height:0}#detail_decorate_root .magic-22{margin-bottom:0}#detail_decorate_root .magic-23{position:relative;width:100%}#detail_decorate_root .magic-24{overflow:hidden;width:750px;height:1078px;margin-top:0;margin-bottom:0;margin-left:0;margin-right:0}#detail_decorate_root .magic-25{margin-top:0;margin-left:0;width:750px;height:1078px}#detail_decorate_root .magic-26{overflow:hidden;width:750px;height:814px;margin-top:0;margin-bottom:0;margin-left:0;margin-right:0}#detail_decorate_root .magic-27{margin-top:0;margin-left:0;width:750px;height:814px}#detail_decorate_root .magic-28{overflow:hidden;width:750px;height:758px;margin-top:0;margin-bottom:0;margin-left:0;margin-right:0}#detail_decorate_root .magic-29{margin-top:0;margin-left:0;width:750px;height:758px}#detail_decorate_root .magic-30{overflow:hidden;width:750px;height:583px;margin-top:0;margin-bottom:0;margin-left:0;margin-right:0}#detail_decorate_root .magic-31{margin-top:0;margin-left:0;width:750px;height:583px}#detail_decorate_root .magic-32{overflow:hidden;width:750px;height:893px;margin-top:0;margin-bottom:0;margin-left:0;margin-right:0}#detail_decorate_root .magic-33{margin-top:0;margin-left:0;width:750px;height:893px}#detail_decorate_root .magic-34{overflow:hidden;width:750px;height:675px;margin-top:0;margin-bottom:0;margin-left:0;margin-right:0}#detail_decorate_root .magic-35{margin-top:0;margin-left:0;width:750px;height:675px}#detail_decorate_root .magic-36{overflow:hidden;width:750px;height:76px;margin-top:0;margin-bottom:0;margin-left:0;margin-right:0}#detail_decorate_root .magic-37{margin-top:0;margin-left:0;width:750px;height:76px}\n\u003c\/style\u003e\n\u003cdiv data-magic-global=\"%7B%22bizId%22%3A2217607044645%2C%22pageId%22%3A200109709425%2C%22siteId%22%3A10100897032%7D\" id=\"detail_decorate_root\"\u003e\n\u003cdiv module-id=\"201241455399\" module-title=\"detailHorizontalImageText\" render=\"true\"\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003ch1\u003e\u003cspan style=\"color: rgb(13, 67, 146);\"\u003eOverview\u003c\/span\u003e\u003c\/h1\u003e\n\u003cdiv\u003eThe technology module SITRANS FST070 is an ultrasonic clamp-on flowmeter transmitter for the SIMATIC ET200SP.The TM SITRANS FST070 flow transmitter can be operated directly in the SIMATIC PCS 7 or in TIA Portal with the FST070 faceplates.SITRANS FST070 offers real-time data processing and the display of all measuring and status data of the Ultrasonic flowmeter.The TM FST070 can work with all Siemens ultrasonic clamp-on flowmeters. It can be connected to the FS DSL with FSS200 clamp-on sensors.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv module-id=\"201241455400\" module-title=\"detailTextWithTitle\" render=\"true\"\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003ch1\u003e\u003cspan style=\"color: rgb(13, 67, 146);\"\u003eBenefits\u003c\/span\u003e\u003c\/h1\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e* Easy integration into automation process control as TIA portal and PCS7 (SIMATIC)\u003cbr\u003e* Easy selection and integration of flowmeters via TIA selector\u003cbr\u003e* Precast face plates for TIA portal and PCS7\u003cbr\u003e* No additional transmitter between automation and clamp-on sensors required\u003cbr\u003e* Cost effective integration of clamp-on flowmeters for water treatments, control rooms with PCS7\u003cbr\u003e* SITRANS FST070 ET 200SP technology module can combined with all other SIMATIC ET200 modules\u003cbr\u003e* Fast and trouble-free communication between the flowmeter and the PLC through digital data communication with up to 10 ms update rate\u003cbr\u003e* SITRANS FST070 and ET 200SP have the ATEX Zone 2 Class 1 Div 2 approvals. With the barrier SITRANS I300 the flowmeters sensor can be used in Ex Zone 1\/0 Class 1 Div 1 approval\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv module-id=\"201241455401\" module-title=\"detailTextWithTitle\" render=\"true\"\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003ch1\u003e\u003cspan style=\"color: rgb(13, 67, 146);\"\u003eApplication\u003c\/span\u003e\u003c\/h1\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cdiv\u003eSITRANS FST070 can be used for machine builders, in the chemical industry or water treatments. The meters are suitable for measuring on liquid, hydrocarbon and gas. With ET 200SP the SITRANS FST070 can be installed decentralized in small stations, with fast communication to the control room. The faceplates for TIA portal and PCS 7 offer the direct full remote access to the flowmeter. The main industries for the SITRANS FST070 transmitter:\u003cbr\u003e* Chemical\u003cbr\u003e* Pharmaceutical\u003cbr\u003e* District Energy\u003cbr\u003e* Water and waste water\u003cbr\u003e* Oil\u003cbr\u003e* Gas\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv module-id=\"201241455402\" module-title=\"detailTextWithTitle\" render=\"true\"\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003ch1\u003e\u003cspan style=\"color: rgb(13, 67, 146);\"\u003eDesign\u003c\/span\u003e\u003c\/h1\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cdiv\u003eThe SITRANS FST070 is designed as ET200 SP module and can directly installed with other ET200 SP modules. The FS DSL cable is directly mounted to the ET 200SP base unit is providing the supply voltage and the data communication. The SITRANS FSS200 clamp-on sensors with FS DSL can be connected directly to the SITRANS FST070. For sensors in ATEX Zone 0 or 1, the SITRANS I300 barrier must be installed between FST070 and the FS DSL.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv module-id=\"201241455403\" module-title=\"detailTextWithTitle\" render=\"true\"\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003ch1\u003e\u003cspan style=\"color: rgb(13, 67, 146);\"\u003eFunction\u003c\/span\u003e\u003c\/h1\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cdiv\u003eThe following key functionalities are available:\u003cbr\u003e* Volume flow rate, mass flow, flow velocity, density, temperature, pressure. kinematic viscosity, standard volume flow\u003cbr\u003e(hydrocarbon)\u003cbr\u003e* Three built-in totalizers which can freely be set for counting volume flow, mass flow\u003cbr\u003e* Two digital inputs\u003cbr\u003e* Two digital outputs\u003cbr\u003e* Low flow cut-off\u003cbr\u003e* Zero point adjustment\u003cbr\u003e* Configurable upper and lower alarm and warning limits for all process values\u003cbr\u003e* Comprehensive status and error reporting\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv module-id=\"201239241439\" module-title=\"detailProductNavigation\" render=\"true\"\u003e\n\u003ch1 data-section=\"AliMagic-tue4ui\" data-section-title=\"Specification\" id=\"ali-anchor-AliMagic-tue4ui\"\u003e\u003cspan style=\"color: rgb(13, 67, 146);\"\u003eSpecification\u003c\/span\u003e\u003c\/h1\u003e\n\u003c\/div\u003e\n\u003cdiv module-id=\"201239241440\" module-title=\"detailTableHorizontal\" render=\"true\"\u003e\n\u003cdiv\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e\n\u003cdiv\u003eitem\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e\n\u003cdiv\u003evalue\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e\n\u003cdiv\u003eWarranty\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e\n\u003cdiv\u003e1 Year\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e\n\u003cdiv\u003eCustomized support\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e\n\u003cdiv\u003eOEM\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e\n\u003cdiv\u003ePlace of Origin\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e\n\u003cdiv\u003eGermany\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e\n\u003cdiv\u003eBrand Name\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e\n\u003cdiv\u003eSIEMENS\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e\n\u003cdiv\u003eModel Number\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e\n\u003cdiv\u003eFST070\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e\n\u003cdiv\u003eType\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e\n\u003cdiv\u003eUltrasonic meters\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e\n\u003cdiv\u003eTechnology Modul\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e\n\u003cdiv\u003eFor SIMATIC ET 200SP Profinet\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e\n\u003cdiv\u003eBase Unit ET 200SP\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e\n\u003cdiv\u003eBU 20 type B1\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e\n\u003cdiv\u003eSupported Control\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e\n\u003cdiv\u003eSSIMATIC PCS7 V9.1 SP2 or higher\u003cbr\u003eTIA Portal V17 or higher\u003cbr\u003eSIMATIC STEP 7 V5.6 SP4 or higher\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e\n\u003cdiv\u003eOutputs\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e\n\u003cdiv\u003e2 individually programmable outputs\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e\n\u003cdiv\u003eInputs\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e\n\u003cdiv\u003e2 individually programmable outputs\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e\n\u003cdiv\u003eCommunication\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e\n\u003cdiv\u003eProfinet via SIMATIC ET 200SP\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e\n\u003cdiv\u003eProtection Class\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e\n\u003cdiv\u003eIP 20\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e\n\u003cdiv\u003eEnvironmental Temperature\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e\n\u003cdiv\u003e-13° F...122 °F Vertical (140°F)\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e\n\u003cdiv\u003ePower\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e\n\u003cdiv\u003e24V, Class 2, max. 0.5 A\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e\n\u003cdiv\u003eApprovals\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e\n\u003cdiv\u003eCE cULus EAC Tick KCC ROHS\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e\n\u003cdiv\u003eApprovals (Ex version)\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e\n\u003cdiv\u003eATEX II 3 G Ex ec IIC T.. Gc\u003cbr\u003eIECEx Ex ec IIC T4\u003cbr\u003eFM Class I, DIV 2, Group A.B.C.D\u003cbr\u003eWith barrier SITRANS I300 also for ATEX zone 1\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv module-id=\"201238410285\" module-title=\"detailManyImage\" render=\"true\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c\/div\u003e","brand":"SIEMENS","offers":[{"title":"Default Title","offer_id":48020393263321,"sku":null,"price":350.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0016\/5327\/6707\/files\/SIEMENS_359dfacd-7cdc-4176-8f0c-6c0b855c6841.png?v=1771971034","url":"https:\/\/www.aloinfousa.com\/pt\/products\/siemens-ultrasonic-clamp-on-flow-measurement-sitrans-fst070-7me372-7me3448-6es7193","provider":"aloinfousa.com","version":"1.0","type":"link"}