{"product_id":"cisco-c9200l-48t-4x-a-switch","title":"Cisco C9200L-48T-4X-A Switch","description":"\u003cdiv class=\"short-hide\"\u003e[shortdesc]\n\u003cul\u003e\n\u003cli\u003eSwitch\u003c\/li\u003e\n\u003cli\u003eL3\u003c\/li\u003e\n\u003cli\u003e48 x 10\/100\/1000 + 4 x 10 Gigabit SFP+ (uplink\u003c\/li\u003e\n\u003cli\u003eRack-mountable\u003c\/li\u003e\n\u003c\/ul\u003e\n[\/shortdesc]\u003c\/div\u003e\n\u003cp\u003e[properties]\u003c\/p\u003e\n\u003ctable xmlns=\"http:\/\/www.w3.org\/1999\/xhtml\" cellspacing=\"0\" cellpadding=\"0\" dir=\"ltr\" border=\"1\"\u003e\n\u003ccolgroup\u003e \u003ccol width=\"251\"\u003e \u003ccol width=\"258\"\u003e \u003c\/colgroup\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"Properties\"}'\u003eProperties\u003c\/td\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"C9200L-48T-4X-E\"}'\u003eC9200L-48T-4X-A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"Description\"}'\u003eDescription\u003c\/td\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"Catalyst 9200L 48-port Data 4x10G uplink Switch, Network Essentials\"}'\u003eCatalyst 9200L 48-port Data 4x10G uplink Switch, Network Advantage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"Product Family\"}'\u003eProduct Family\u003c\/td\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"Catalyst 9200-L\"}'\u003eCatalyst 9200-L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"Product Type\"}'\u003eProduct Type\u003c\/td\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"Ethernet Switch\"}'\u003eEthernet Switch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"Number of Ports\"}'\u003eNumber of Ports\u003c\/td\u003e\n\u003ctd data-sheets-value='{\"1\":3,\"3\":48}'\u003e48\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"Downlinks total 10\/100\/1000\\nor PoE+ copper ports\"}'\u003eDownlinks total 10\/100\/1000\u003cbr\u003eor PoE+ copper ports\u003c\/td\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"48 ports data \"}'\u003e48 ports data\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"Uplink configuration\"}'\u003eUplink configuration\u003c\/td\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"4x 1G fixed uplinks\"}'\u003e4x 1G fixed uplinks\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"Cisco IOS Software\"}'\u003eCisco IOS Software\u003c\/td\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"Network Essentials\"}'\u003eNetwork Advantage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"Default primary AC\\npower supply\"}'\u003eDefault primary AC\u003cbr\u003epower supply\u003c\/td\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"PWR-C5-125WAC\"}'\u003ePWR-C5-125WAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"Available PoE power with\\nadditional secondary\\npower supply\"}'\u003eAvailable PoE power with\u003cbr\u003eadditional secondary\u003cbr\u003epower supply\u003c\/td\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"-\"}'\u003e-\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"Fans\"}'\u003eFans\u003c\/td\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"Fixed redundant\"}'\u003eFixed redundant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"Chassis + FEP +\\n Fan Dimensions (HxWxD Inches\"}'\u003eChassis + FEP +\u003cbr\u003eFan Dimensions (HxWxD Inches\u003c\/td\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"1.73 x 17.5 x 11.3\"}'\u003e1.73 x 17.5 x 11.3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e[\/properties][specifications]\u003c\/p\u003e\n\u003ctable xmlns=\"http:\/\/www.w3.org\/1999\/xhtml\" cellspacing=\"0\" cellpadding=\"0\" dir=\"ltr\" border=\"1\"\u003e\n\u003ccolgroup\u003e \u003ccol width=\"274\"\u003e \u003ccol width=\"256\"\u003e \u003c\/colgroup\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"Specifications\"}'\u003eSpecifications\u003c\/td\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"C9200L-48T-4X-E\"}'\u003eC9200L-48T-4X-A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"Console Ports\"}'\u003eConsole Ports\u003c\/td\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"RJ-45-to-DB9 cable for PC connections, USB-C adaptor, USB adaptor\"}'\u003eRJ-45-to-DB9 cable for PC connections, USB-C adaptor, USB adaptor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"DRAM\"}'\u003eDRAM\u003c\/td\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"2 GB\"}'\u003e2 GB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"Flash Memory\"}'\u003eFlash Memory\u003c\/td\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"4 GB\"}'\u003e4 GB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"Switching capacity\"}'\u003eSwitching capacity\u003c\/td\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"176 Gbps\"}'\u003e176 Gbps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"Forwarding rate \"}'\u003eForwarding rate\u003c\/td\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"130.95 Mpps\"}'\u003e130.95 Mpps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"MTBF Hours\"}'\u003eMTBF Hours\u003c\/td\u003e\n\u003ctd data-sheets-value='{\"1\":3,\"3\":503400}'\u003e503400\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"MAC addresses\"}'\u003eMAC addresses\u003c\/td\u003e\n\u003ctd data-sheets-value='{\"1\":3,\"3\":16000}'\u003e16000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"Operating Temperature\\nUp to 5,000 ft (1500 m\"}'\u003eOperating Temperature\u003cbr\u003eUp to 5,000 ft (1500 m\u003c\/td\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"-5°C to +45°C\",\"6\":1}'\u003e-5°C to +45°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"Operating Temperature\\nUp to 10,000 ft (3000 m\"}'\u003eOperating Temperature\u003cbr\u003eUp to 10,000 ft (3000 m\u003c\/td\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"-5°C to +40°C\",\"6\":1}'\u003e-5°C to +40°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"Safety\"}'\u003eSafety\u003c\/td\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"IEC 60950-1\\nUL 60950-1\\nCAN\/CSA C22.2 No. 60950-1\\nEN 60950-1\\nAS\/NZS 60950.1\\nClass I Equipment\"}'\u003eIEC 60950-1\u003cbr\u003eUL 60950-1\u003cbr\u003eCAN\/CSA C22.2 No. 60950-1\u003cbr\u003eEN 60950-1\u003cbr\u003eAS\/NZS 60950.1\u003cbr\u003eClass I Equipment\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"Electromagnetic compatibility\\ncertifications\"}'\u003eElectromagnetic compatibility\u003cbr\u003ecertifications\u003c\/td\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"47 CFR Part 15\\nCISPR 32 Class A\\nCNS 13438\\nEN 300 386*\\nEN 55032 Class A\\nEN61000-3-2\\nEN61000-3-3\\nICES-003 Class A\\nKN 32\\nTCVN 7189 Class A\\nV-3 Class A\\nCISPR 35\\nEN 300 386*\\nEN 55035\\nKN 35\\nTCVN 7317\"}'\u003e47 CFR Part 15\u003cbr\u003eCISPR 32 Class A\u003cbr\u003eCNS 13438\u003cbr\u003eEN 300 386*\u003cbr\u003eEN 55032 Class A\u003cbr\u003eEN61000-3-2\u003cbr\u003eEN61000-3-3\u003cbr\u003eICES-003 Class A\u003cbr\u003eKN 32\u003cbr\u003eTCVN 7189 Class A\u003cbr\u003eV-3 Class A\u003cbr\u003eCISPR 35\u003cbr\u003eEN 300 386*\u003cbr\u003eEN 55035\u003cbr\u003eKN 35\u003cbr\u003eTCVN 7317\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"EMC\\ncompliance\"}'\u003eEMC\u003cbr\u003ecompliance\u003c\/td\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"FCC Part 15 (CFR 47 Class A\\nICES-003 Class A\\nEN 55032 Class A\\nCISPR 32 Class A\\nAS\/NZS 3548 Class A\\nBSMI Class A\\nVCCI Class A\\nCISPR 35\\nEN 55035, EN300 386*\\nEN 61000-3-2, EN 61000-3-3\"}'\u003eFCC Part 15 (CFR 47 Class A\u003cbr\u003eICES-003 Class A\u003cbr\u003eEN 55032 Class A\u003cbr\u003eCISPR 32 Class A\u003cbr\u003eAS\/NZS 3548 Class A\u003cbr\u003eBSMI Class A\u003cbr\u003eVCCI Class A\u003cbr\u003eCISPR 35\u003cbr\u003eEN 55035, EN300 386*\u003cbr\u003eEN 61000-3-2, EN 61000-3-3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"Safety\\ncompliance\"}'\u003eSafety\u003cbr\u003ecompliance\u003c\/td\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"UL 60950-1, CAN\/CSA-C22.2 No. 60950-1, EN 60950-1, IEC 60950-1, CCC, CE Marking\"}'\u003eUL 60950-1, CAN\/CSA-C22.2 No. 60950-1, EN 60950-1, IEC 60950-1, CCC, CE Marking\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"Environmental\"}'\u003eEnvironmental\u003c\/td\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"Reduction of Hazardous Substances (ROHS 5\"}'\u003eReduction of Hazardous Substances (ROHS 5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"Stacking Support\"}'\u003eStacking Support\u003c\/td\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"StackWise-80\"}'\u003eStackWise-80\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"Stacking bandwidth support\"}'\u003eStacking bandwidth support\u003c\/td\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"80 Gbps\"}'\u003e80 Gbps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"Stacking hardware \"}'\u003eStacking hardware\u003c\/td\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"C9200L-STACK-KIT\"}'\u003eC9200L-STACK-KIT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"Number of\\nmembers\"}'\u003eNumber of\u003cbr\u003emembers\u003c\/td\u003e\n\u003ctd data-sheets-value='{\"1\":3,\"3\":8}'\u003e8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"Supported stack members\"}'\u003eSupported stack members\u003c\/td\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"Other C9200L models with same license level\"}'\u003eOther C9200L models with same license level\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e[\/specifications][accesories]\u003c\/p\u003e\n\u003ctable xmlns=\"http:\/\/www.w3.org\/1999\/xhtml\" cellspacing=\"0\" cellpadding=\"0\" dir=\"ltr\" border=\"1\"\u003e\n\u003ccolgroup\u003e \u003ccol width=\"165\"\u003e \u003ccol width=\"158\"\u003e \u003c\/colgroup\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"1\" colspan=\"2\" data-sheets-value='{\"1\":2,\"2\":\"Mounting Accessories\"}'\u003eMounting Accessories\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"ACC-KIT-T1=\"}'\u003eACC-KIT-T1=\u003c\/td\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"Accessory kit with 19 inch Type 1 rack mount\"}'\u003eAccessory kit with 19 inch Type 1 rack mount\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"RACK-KIT-T1=\"}'\u003eRACK-KIT-T1=\u003c\/td\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"19, 23, 24 inch and ETSI Type 1 rack mount kit\"}'\u003e19, 23, 24 inch and ETSI Type 1 rack mount kit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"4PT-KIT-T2=\"}'\u003e4PT-KIT-T2=\u003c\/td\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"4 Point rack mount kit New\"}'\u003e4 Point rack mount kit New\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"C9K-MGNT-TRAY\"}'\u003eC9K-MGNT-TRAY\u003c\/td\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"Magnet and Mounting Tray for compact switches\"}'\u003eMagnet and Mounting Tray for compact switches\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"C9K-CMPCT-DIN-MNT\"}'\u003eC9K-CMPCT-DIN-MNT\u003c\/td\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"DIN Rail Mount for compact switches\"}'\u003eDIN Rail Mount for compact switches\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"RACKMNT-19-CMPACT\"}'\u003eRACKMNT-19-CMPACT\u003c\/td\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"19-Inch Rack Mounting Brackets for compact switches\"}'\u003e19-Inch Rack Mounting Brackets for compact switches\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"C9K-CMPCT-CBLE-GRD\"}'\u003eC9K-CMPCT-CBLE-GRD\u003c\/td\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"Cable guard for compact switches (for C9K-WALL-TRAY\"}'\u003e\n\u003cdiv\u003e\n\u003cdiv\u003eCable guard for compact switches (for C9K-WALL-TRAY\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"C9K-WALL-TRAY\"}'\u003eC9K-WALL-TRAY\u003c\/td\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"Wall mount bracket for compact switches\"}'\u003e\n\u003cdiv\u003e\n\u003cdiv\u003eWall mount bracket for compact switches\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"C9K-CMPCT-DESK-MNT\"}'\u003eC9K-CMPCT-DESK-MNT\u003c\/td\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"Under desk mount for compact switches\"}'\u003e\n\u003cdiv\u003e\n\u003cdiv\u003eUnder desk mount for compact switches\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"1\" colspan=\"2\" data-sheets-value='{\"1\":2,\"2\":\"Stacking accessories\"}'\u003eStacking accessories\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"C9200L-STACK-KIT\"}'\u003eC9200L-STACK-KIT\u003c\/td\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"Stack kit for C9200L SKUs only: Two data stack adapters and one data stack cable\"}'\u003eStack kit for C9200L SKUs only: Two data stack adapters and one data stack cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"STACK-T4-50CM\"}'\u003eSTACK-T4-50CM\u003c\/td\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"Data stack 50 cm cable (default cable with Stack Kit\"}'\u003eData stack 50 cm cable (default cable with Stack Kit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"STACK-T4-1M\"}'\u003eSTACK-T4-1M\u003c\/td\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"Data stack 1 m cable\"}'\u003eData stack 1 m cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"STACK T4-3M\"}'\u003eSTACK T4-3M\u003c\/td\u003e\n\u003ctd data-sheets-value='{\"1\":2,\"2\":\"Data stack 3 m cable\"}'\u003eData stack 3 m cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e[\/accesories]\u003c\/p\u003e\n\u003ch2\u003eCisco Catalyst C9200L-48T-4X-A Switch\u003c\/h2\u003e\n\u003cp\u003eThe Cisco Catalyst C9200L-48T-4X-A Switch is an enterprise-class networking solution that delivers high performance, security, and scalability, making it ideal for small to medium-sized businesses and branch offices. This switch features 48 Gigabit Ethernet ports and 4 fixed 10G SFP+ uplinks, ensuring reliable and high-speed connectivity for various network devices. The C9200L-48T-4X-A is equipped with advanced security features, Layer 3 routing capabilities, and easy management through Cisco DNA Center, providing a robust and efficient network infrastructure.\u003c\/p\u003e\n\u003ch3\u003eKey Features:\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e48 x Gigabit Ethernet Ports:\u003c\/strong\u003e Provides fast and reliable connectivity for various network devices, ensuring smooth and efficient network operations.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e4 x 10G SFP+ Uplinks:\u003c\/strong\u003e Offers high-speed uplink options for connecting to other switches or network devices, ensuring network scalability and performance.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAdvanced Security:\u003c\/strong\u003e Includes features such as MACsec encryption and segmentation for enhanced network protection.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLayer 3 Routing:\u003c\/strong\u003e Supports static routing, OSPF, EIGRP stub, and routed access for efficient traffic management and network segmentation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEasy Management:\u003c\/strong\u003e Managed through Cisco DNA Center, CLI, and a web-based UI, simplifying network operations.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Overview:\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eRecommended for:\u003c\/strong\u003e Small to medium-sized businesses, branch offices, and enterprise networks requiring robust and secure 10G connectivity.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePorts:\u003c\/strong\u003e 48 x 10\/100\/1000 Mbps Gigabit Ethernet ports with 4 fixed 10G SFP+ uplinks.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSwitching Capacity:\u003c\/strong\u003e 176 Gbps.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eForwarding Rate:\u003c\/strong\u003e 130.95 Mpps.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManagement:\u003c\/strong\u003e Cisco DNA Center, CLI, and web-based GUI for comprehensive network management.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSecurity:\u003c\/strong\u003e MACsec encryption and advanced segmentation for enhanced network security.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnergy Efficiency:\u003c\/strong\u003e Compliant with IEEE 802.3az Energy Efficient Ethernet.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eYou can check the related tab for the C9200L-48T-4X-A datasheet.\u003c\/p\u003e","brand":"Cisco","offers":[{"title":"Default Title","offer_id":47669887172825,"sku":"C9200L-48T-4X-A-NEW","price":8679.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0016\/5327\/6707\/files\/c9200l-48t-4x-a_1.webp?v=1767389881","url":"https:\/\/www.aloinfousa.com\/su\/products\/cisco-c9200l-48t-4x-a-switch","provider":"aloinfousa.com","version":"1.0","type":"link"}