item
|
value
|
|
Warranty
|
1 Year
|
|
Customized support
|
OEM
|
|
Place of Origin
|
Switzerland
|
|
Brand Name
|
Endress+Hauser
|
|
Model Number
|
Promass F200
|
|
Type
|
Coriolis meters, Coriolis flowmeter
|
|
Measuring Principle
|
Coriolis
|
|
Product Headline
|
Robust flowmeter with genuine loop-powered technology. Highest measurement performance for liquids and gases in a wide range of applications.
|
|
Sensor Features
|
Highest process safety – immune to fluctuating and harsh environments. Fewer process measuring points – multivariable measurement (flow, density, temperature). Space‐saving installation – no in-/outlet run needs. Mass flow: measured error ±0.1 %. Medium temperature up to +205 °C (+401 °F). Nominal diameter: DN 8 to 80 (³⁄₈ to 3").
|
|
Transmitter Features
|
Convenient device wiring – separate connection compartment. Safe operation – no need to open the device due to display with touch control, background lighting. Integrated verification – Heartbeat Technology. Loop-powered technology. Robust dual-compartment housing. Plant safety: worldwide approvals (SIL, Haz. area).
|
|
Nominal Diameter Range
|
DN 8 to 80 (⅜ to 3")
|
|
Wetted Materials
|
Measuring tube: 1.4539 (904L); 1.4404; Alloy C22, 2.4602 (UNS N06022) Connection: 1.4404 (316/316L); Alloy C22, 2.4602 (UNS N06022)
|
|
Measured Variables
|
Mass flow, density, temperature, volume flow, corrected volume flow, reference density, concentration
|
|
Max. Measurement Error
|
Mass flow (liquid): ±0.1 % Volume flow (liquid): ±0.1 % Mass flow (gas): ±0.25 % Density (liquid): ±0.0005 g/cm³
|
|
Measuring Range
|
0 to 70 000 kg/h (0 to 2570 lb/min)
|
|
Max. Process Pressure
|
PN 100, Class 600, 63K
|
|
Medium Temperature Range
|
Standard: –50 to +150 °C (–58 to +302 °F) Option: –50 to +205 °C (–58 to +401 °F)
|
|
Ambient Temperature Range
|
–40 to +60 °C (–40 to +140 °F)
|
|
Sensor Housing Material
|
1.4301/1.4307 (304L), corrosion resistant
|
|
Transmitter Housing Material
|
AlSi10Mg, coated, 1.4404 (316L)
|
|
Degree Of Protection
|
IP66/67, type 4X enclosure
|
|
Display/Operation
|
4‐line backlit display with touch control (operation from outside) Configuration via local display and operating tools possible Remote display available
|
|
Outputs
|
4‐20 mA HART (passive) 4‐20 mA (passive) Pulse/frequency/switch output (passive)
|
|
Inputs
|
None
|
|
Digital Communication
|
HART, PROFIBUS PA, FOUNDATION Fieldbus
|
|
Power Supply
|
DC 18 to 35 V (4‐20 mA HART with/without pulse/frequency/switch) DC 18 to 30 V (20 mA HART, 4‐20 mA) DC 9 to 32 V (PROFIBUS PA)
|
|
Hazardous Area Approvals
|
ATEX, IECEx, cCSAus, INMETRO, NEPSI, JPN, UK Ex
|
|
Product Safety
|
CE, C-TICK
|
|
Functional Safety
|
Functional safety according to IEC 61508, applicable in safety-relevant applications in accordance with IEC 61511
|
|
Metrological Approvals And Certificates
|
Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025) Heartbeat Technology complies with the requirements for measurement traceability according to ISO 9001:2015 – Section 7.1.5.2 a (TÜV SÜD attestation)
|
|
Marine Approvals And Certificates
|
ABS (American Bureau of Shipping) BV (Bureau Veritas) LR (Lloyds Register) BV approval CCS approval
|
|
Pressure Approvals And Certificates
|
PED, CRN, AD 2000
|
|
Material Certificates
|
3.1 material NACE MR0175/MR0103, PMI; welding test acc. to EN ISO, ASME, NORSOK
|
|
Hygienic Approvals And Certificates
|
3-A, EHEDG, cGMP
|